K251643 · Wright Medical Technology, Inc. (Stryker Corporation) · HTN · Oct 29, 2025 · Orthopedic
Device Facts
Record ID
K251643
Device Name
Synchfix EVT
Applicant
Wright Medical Technology, Inc. (Stryker Corporation)
Product Code
HTN · Orthopedic
Decision Date
Oct 29, 2025
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic
Intended Use
Synchfix EVT is intended for soft tissue and bone fixation for ankle syndesmosis disruptions with or without ankle fractures and as an adjunct in connection with hardware for ankle fractures such as Weber B, Weber C and Maisonneuve in adult and adolescent patient populations.
Device Story
Synchfix EVT is a sterile, single-use suture-button system for stabilizing ankle syndesmosis disruptions. System comprises UHMWPE suture tensioned between two titanium alloy buttons; includes pre-loaded inserter and single-use instruments. Used by surgeons in clinical settings to provide bone/soft tissue fixation. Device functions by securing syndesmosis; provides mechanical stability to facilitate healing. Benefits include stabilization of syndesmotic disruptions and adjunct fixation for specific ankle fractures.
Clinical Evidence
No clinical data. Substantial equivalence determined via non-clinical bench testing, including static pullout strength and dynamic fatigue mechanical testing.
Technological Characteristics
Materials: UHMWPE suture, titanium alloy buttons. Form factor: Suture-button system with pre-loaded inserter. Single-use, sterile. Mechanical fixation principle. No software or electronic components.
Indications for Use
Indicated for soft tissue and bone fixation for ankle syndesmosis disruptions (with/without ankle fractures) and as an adjunct for ankle fractures (Weber B, Weber C, Maisonneuve) in adult and adolescent patients.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
K252081 — SportLinc Syndesmosis Device · Lincotek Medical · Mar 27, 2026
K220260 — Hercules Syndesmosis Implant System · In2bones USA, LLC · Mar 31, 2022
K043248 — TIGHTROPE SYNDESMOSIS REPAIR KIT, TITANIUM, MODEL AR-8920DS; STAINLESS STEEL. MODEL AR-8921DS · Arthrex, Inc. · Feb 16, 2005
K242091 — Bolo Button System · Fusion Orthopedics · Dec 23, 2024
K192964 — Parcus Synd-EZ SS · Parcus Medical, LLC · Nov 22, 2019
Submission Summary (Full Text)
{0}
FDA U.S. FOOD & DRUG ADMINISTRATION
October 29, 2025
Wright Medical Technology, Inc (Stryker Corporation)
Rachel Warnock
Staff Regulatory Affairs Specialist
1023 Cherry Rd
Memphis, Tennessee 38117
Re: K251643
Trade/Device Name: Synchfix EVT
Regulation Number: 21 CFR 888.3030
Regulation Name: Single/Multiple Component Metallic Bone Fixation Appliances And Accessories
Regulatory Class: Class II
Product Code: HTN, HRS
Dated: September 19, 2025
Received: September 19, 2025
Dear Rachel Warnock:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov
{1}
K251643 - Rachel Warnock
Page 2
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-
{2}
K251643 - Rachel Warnock
Page 3
assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
CHRISTOPHER FERREIRA -S
Christopher Ferreira, M.S.
Assistant Director
DHT6C: Division of Restorative,
Repair, and Trauma Devices
OHT6: Office of Orthopedic Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health
Enclosure
{3}
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration
Indications for Use
Form Approved: OMB No. 0910-0120
Expiration Date: 07/31/2026
See PRA Statement below.
Submission Number (if known)
K251643
Device Name
Synchfix EVT
Indications for Use (Describe)
Synchfix EVT is intended for soft tissue and bone fixation for ankle syndesmosis disruptions with or without ankle fractures and as an adjunct in connection with hardware for ankle fractures such as Weber B, Weber C and Maisonneuve in adult and adolescent patient populations.
Type of Use (Select one or both, as applicable)
☑ Prescription Use (Part 21 CFR 801 Subpart D)
☐ Over-The-Counter Use (21 CFR 801 Subpart C)
# CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
*DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}
K251643
stryker
510(K) SUMMARY: Synchfix™ EVT
(a)(1). Submitted By:
Wright Medical Technology, Inc.
1023 Cherry Road
Memphis, TN 38117
Date:
October 28th, 2025
Contact Person:
Rachel Warnock
Staff Specialist, Regulatory Affairs
Secondary Contact:
Alayne Melancon
Manager, Regulatory Affairs
(a)(2). Proprietary Name:
Synchfix™ EVT
Common Name:
Washer, Bolt, Nut
Classification Name and Reference:
21 CFR 888.3030 – Single/multi component metallic bone fixation appliances and accessories
Device Product Code, Device Panel:
HTN – Orthopedic
HRS – Orthopedic
(a)(3). Primary Predicate Device(s):
GRAVITY™ Syndesmosis LP (K170249)
(a)(4). Device Description
The subject device, Synchfix™ EVT, is a sterile, single-use, suture-button system intended to stabilize syndesmotic disruptions in the ankle. The subject system consists of a UHMWPE suture tensioned between two titanium alloy buttons and single use instruments to assist in implantation, including a pre-loaded inserter.
(a)(5). Indications for Use
Synchfix™ EVT is intended for soft tissue and bone fixation for ankle syndesmosis disruptions with or without ankle fractures and as an adjunct in connection with hardware for ankle fractures such as Weber B, Weber C and Maisonneuve in adult and adolescent patient populations.
(a)(6). Technological Characteristics Comparison
The subject Synchfix™ EVT is substantially equivalent to the predicate device in material and design.
There is no change in the fundamental scientific technology shared by both the subject and predicate devices. The subject and predicate implants have similar materials, design features, instrumentation, and performance characteristics. Mechanical testing has
Synchfix™ EVT – 510(k) Summary
{5}
K251643
stryker
confirmed substantial equivalence of the subject device, demonstrating that the technological characteristics do not raise new questions of safety or effectiveness.
The Indications for Use of the subject device differ from those of the predicate device in that the subject device is intended for use in both adolescent and adult patient populations. Additionally, the subject device's Indications for Use include the addition of Maisonneuve fractures.
(b)(1). Substantial Equivalence - Non-Clinical Evidence
Non-clinical performance bench testing (static pullout strength and dynamic fatigue mechanical testing) was performed to demonstrate substantial equivalence to the predicate device.
(b)(2). Substantial Equivalence - Clinical Evidence
N/A - Clinical testing was not necessary for the determination of substantial equivalence.
(b)(3). Substantial Equivalence - Conclusions
The subject device and predicate device share similar design features, basic fundamental scientific technology, principles of operation, materials, and intended use. The differences between the subject device and predicate device do not raise any new questions of safety or effectiveness. From the evidence submitted in this Traditional 510(k), the subject device can be expected to perform at least as well as the predicate device and are substantially equivalent.
Synchfix™ EVT – 510(k) Summary
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.