HRY · Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer

Orthopedic · 21 CFR 888.3530 · Class 2

Overview

Product CodeHRY
Device NameProsthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
Regulation21 CFR 888.3530
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (§ 888.3027).

Classification Rationale

Class II.

Recent Cleared Devices (20 of 92)

Showing 20 most recent of 92 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K193549SIGMA High Performance (HP) Partial Knee SystemDepuy Ireland UCApr 16, 2020SESE
K190633NanoOrtho NanoKnee® SystemNanoortho, LLCDec 20, 2019SESE
K152631MPO Total Knee Systems MR LabelingMicroport Orthopedics, Inc.Mar 23, 2016SESE
K150410RESTORIS POROUS PARTIAL KNEE SYSTEMMako Surgical CorporationMar 20, 2015SESE
K133940OXFORD FIXED LATERAL BEARING PARTIAL KNEE REPLACEMENT (BEARINGS / TRAYS)Biomet UK, Ltd.Mar 28, 2014SESE
K131167UNIVATIONAesculap Implant Systems, LLCOct 17, 2013SESE
K122277OXFORD FIXED LATERAL BEARING PARTIAL KNEE REPLACEMENT (OXFORD TIBIAL TRAYS A-F) IXFORD PARTIAL KNEE REPLACEMENT SYSTEMBiomet Manufacturing CorpOct 22, 2012SESE
K110415SIGNATURE PLANNER / SIGNATURE GUIDESMaterialise NVMay 16, 2011SESE
K100973EVOLUTION UNICONDYLAR KNEE SYSTEMWrightmedicaltechnologyincAug 10, 2010SESE
K082567STRYKER COMPARTMENTAL KNEE SYSTEM LINE EXTENSIONHowmedica Osteonics Corp.Oct 3, 2008SESE
K081293UNIVATION UNICONDYLAR KNEE SYSTEMAesculap Implant Systems, Inc.Sep 22, 2008SESE
K072704UNICOMPARTMENTAL KNEEValpo Orthopedic Technology, Inc.Feb 19, 2008SESE
K071881TRIATHLON PKR SYSTEMHowmedica Osteonics Corp.Oct 9, 2007SESE
K070267DEPUY GCK TIBIAL COMPONENTSDePuy Orthopaedics, Inc.Aug 17, 2007SESE
K063515TITANIUM REPICCI II UNICONDYLAR FEMORAL KNEE COMPONENTS COCR REPICCI II UNICONDYLAR KNEEBiomet Manufacturing, Inc.Feb 2, 2007SESE
K061681REPICCI II METAL BACK INLAY UNICOMPARTMENTAL TIBIAL BEARING COMPONENTBiomet Manufacturing CorpOct 19, 2006SESE
K060412ACTIVE UNICOMPARTMENTAL KNEE SYSTEMAustralian Surgical Design & ManufactureMay 17, 2006SESE
K053299REPICCI II ONLAY UNICOMPARTMENTAL TIBIAL COMPONENTBiomet Manufacturing, Inc.Jan 5, 2006SESE
K051721GLOBAL RESURFACING UNICOMPARTMENTAL KNEE SYSTEMGlobal Orthopaedic Technology, USA, Inc.Oct 26, 2005SESE
K050764UNIGLIDE UNICONDYLAR KNEE PROSTHESISCorin USAAug 24, 2005SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...