QBR · Intranasal Electrostimulation Device For Dry Eye Symptoms

Ophthalmic · 21 CFR 886.5310 · Class 2

Overview

Product CodeQBR
Device NameIntranasal Electrostimulation Device For Dry Eye Symptoms
Regulation21 CFR 886.5310
Device ClassClass 2
Review PanelOphthalmic

Identification

An intranasal electrostimulation device for dry eye symptoms is a prescription non-implantable, electrostimulation device intended to increase tear production for improvement in dry eye symptoms.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

In combination with the general controls of the FD&C Act, the intranasal electrostimulation device for dry eye symptoms is subject to the following special controls: - (1) Clinical performance testing must evaluate improvement of dry eye symptoms under anticipated conditions of use. - (2) Non-clinical performance testing must assess the following electrical output specifications: waveforms, output modes, maximum output voltage, maximum output current, pulse duration, frequency, net charge per pulse, maximum phase charge at 500 ohms, maximum current density, maximum average current, and maximum average power density. - (3) Patient-contacting components of the device must be demonstrated to be biocompatible. - (4) Performance testing must demonstrate the electrical, thermal, and mechanical safety along with electromagnetic compatibility (EMC) of the device in the intended use environment. - (5) Software verification, validation and hazard analysis must be performed. - (6) Training for the proper use of the device must be provided. (7) Physician and patient labeling must include: - a. Summaries of electrical stimulation parameters. - b. Instructions on how to correctly use and maintain the device. - c. Instructions and explanations of all user-interface components. - d. Information related to electromagnetic compatibility classification. - Instructions on how to clean the device. e. - Summaries of clinical performance testing demonstrating safety and effectiveness. f.

*Classification.* Class II (special controls). The special controls for this device are:(1) Clinical performance testing must evaluate improvement of dry eye symptoms under anticipated conditions of use. (2) Non-clinical performance testing must assess the following electrical output specifications: waveforms, output modes, maximum output voltage, maximum output current, pulse duration, frequency, net charge per pulse, maximum phase charge at 500 ohms, maximum current density, maximum average current, and maximum average power density. (3) Patient-contacting components of the device must be demonstrated to be biocompatible. (4) Performance testing must demonstrate the electrical, thermal, and mechanical safety along with electromagnetic compatibility (EMC) of the device in the intended use environment. (5) Software verification, validation, and hazard analysis must be performed. (6) Training for the proper use of the device must be provided. (7) Physician and patient labeling must include: (i) Summaries of electrical stimulation parameters; (ii) Instructions on how to correctly use and maintain the device; (iii) Instructions and explanations of all user-interface components; (iv) Information related to electromagnetic compatibility classification; (v) Instructions on how to clean the device; and (vi) Summaries of clinical performance testing demonstrating safety and effectiveness.

Recent Cleared Devices (2 of 2)

RecordDevice NameApplicantDecision DateDecision
K193589TrueTear Intranasal Tear NeurostimulatorAllerganAug 31, 2020SESE
DEN170086TrueTear Intranasal Tear NeurostimulatorAllerganMay 17, 2018DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...