LXP · Plug, Scleral

Ophthalmic · 21 CFR 886.4155 · Class 2

Overview

Product CodeLXP
Device NamePlug, Scleral
Regulation21 CFR 886.4155
Device ClassClass 2
Review PanelOphthalmic

Identification

A scleral plug is a prescription device intended to provide temporary closure of a scleral incision during an ophthalmic surgical procedure. These plugs prevent intraocular fluid and pressure loss when instruments are withdrawn from the eye. Scleral plugs include a head portion remaining above the sclera, which can be gripped for insertion and removal, and a shaft that fits inside the scleral incision. Scleral plugs are removed before completing the surgery.

Classification Rationale

Class II (special controls). The special controls for the scleral plug are as follows:

Special Controls

*Classification.* Class II (special controls). The special controls for the scleral plug are as follows:(1) The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9 if the material is a surgical grade stainless steel with or without a gold, silver, or titanium coating. The special controls for the surgical grade stainless steel scleral plug (with or without a gold, silver, or titanium coating) are: (i) The device must be demonstrated to be sterile during the labeled shelf life; (ii) The device must be demonstrated to be biocompatible; and (iii) Labeling must include all information required for the safe and effective use of the device, including specific instructions regarding the proper sizing, placement, and removal of the device. (2) The device is not exempt from premarket notification procedures if it is composed of a material other than surgical grade stainless steel (with or without a gold, silver, or titanium coating). The special controls for scleral plugs made of other materials are: (i) The device must be demonstrated to be sterile during the labeled shelf life; (ii) The device must be demonstrated to be biocompatible; (iii) Characterization of the device materials must be performed; (iv) Performance data must demonstrate acceptable mechanical properties under simulated clinical use conditions including insertion and removal of the device; (v) Performance data must demonstrate adequately low levels of the extractables or residues from manufacturing (or processing) of the device; and (vi) Labeling must include all information required for the safe and effective use of the device, including specific instructions regarding the proper sizing, placement, and removal of the device.

Recent Cleared Devices (10 of 10)

RecordDevice NameApplicantDecision DateDecision
K022186SCLERAL PLUGS, 19 AND 20 GAUGEMicrovision, Inc.Feb 26, 2003SESE
K990872SCLERAL PLUGS, 19 AND 20 GAUGEOphthalmic Consultants, Inc.Jul 13, 1999SESE
K945114VISITEC SCLERAL PLUGVisitec Co.Feb 23, 1995SESE
K925671DISPOSABLE SCLERAL PLUGSO.R. Specialties, Inc.Aug 2, 1993SESE
K880953ADVANCED SURGICAL 19 & 20 GAUGE DISP. SCLERAL PLUGAdvanced Surgical Products, Inc.May 13, 1988SESE
K880952PRISMA DISPOSABLE 19 AND 20 GAUGE SCLERAL PLUGSAdvanced Surgical Products, Inc.May 13, 1988SESE
K871604MVS 19 AND MVS 20 GAUGE SCLERAL PLUGSAdvanced Surgical Products, Inc.Jun 12, 1987SESE
K854507STORZ MVS 19 & 20 GAUGE SCLERAL PLUGSStorz Instrument Co.Feb 7, 1986SESE
K840693DISPOSABLE SCLERAL GLOBE PLUGInnovative Surgical Products, Inc.May 22, 1984SESE
K831193SCLERAL PLUGMedical Instrument Development Laboratories, Inc.Jun 30, 1983SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...