KEELER CRYO MASTER & PROBES

K992954 · Keeler Instruments, Inc. · HRN · Dec 21, 1999 · Ophthalmic

Device Facts

Record IDK992954
Device NameKEELER CRYO MASTER & PROBES
ApplicantKeeler Instruments, Inc.
Product CodeHRN · Ophthalmic
Decision DateDec 21, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 886.4170
Device ClassClass 2
AttributesTherapeutic, Pediatric

Indications for Use

The Keeler CryoMaster & Probes are for use in ophthalmic surgery in cryopexy for retinal detachment, cyclo destructive procedures in refractory glaucoma, extraction of fragments within the vitreous cavity, cataract extraction, cryo destruction of lash follicles for trichiasis, and treatment of retinopathy of prematurity (ROP).

Device Story

Keeler CryoMaster & Probes are ophthalmic surgical instruments used for cryosurgical procedures. Device utilizes cryo-technology to achieve localized tissue freezing for therapeutic purposes. Operated by ophthalmologists in surgical settings. Applications include retinal detachment repair, glaucoma management, cataract extraction, and treatment of trichiasis and ROP. Device provides controlled cooling to specific ocular tissues to induce cryo-destruction or facilitate extraction. Benefits include precise tissue targeting and effective management of various ophthalmic conditions.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Ophthalmic cryosurgical system. Consists of a console (CryoMaster) and interchangeable cryo-probes. Operates via gas-based cooling mechanism for localized tissue freezing. Designed for surgical use. No software or electronic algorithms described.

Indications for Use

Indicated for ophthalmic surgery including retinal detachment cryopexy, refractory glaucoma cyclo destruction, vitreous cavity fragment extraction, cataract extraction, trichiasis lash follicle destruction, and retinopathy of prematurity (ROP) treatment.

Regulatory Classification

Identification

A cryophthalmic unit is a device that is a probe with a small tip that becomes extremely cold through the controlled use of a refrigerant or gas. The device may be AC-powered. The device is intended to remove cataracts by the formation of an adherent ice ball in the lens, to freeze the eye and adjunct parts for surgical removal of scars, and to freeze tumors.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol resembling an eagle or a bird in flight, composed of three stylized lines. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 DEC 2 1 1999 Mr. Eugene R. Van Arsdale Marketing Manager Keeler Instruments, Inc. 456 Parkway Broomall, PA 19008 Re: K992954 Trade Name: Keeler CryoMaster & Probes Regulatory Class: II Product Code: 21 CFR 886.4170/Procode 86 HRN Dated: November 22, 1999 Received: November 29, 1999 Dear Mr. Arsdale: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations . {1}------------------------------------------------ Page 2 - Mr. Eugene R. Van Arsdale This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, A. Ralph Rosenthal A. Ralph Rosenthal, M.D. Director Division of Ophthalmic Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ 510(k) Number (if known) K992954 **Page 1 of 1** K992954 Device Name: Keeler CryoMaster & Probes Indications For Use: The Keeler CryoMaster & Probes are for use in ophthalmic surgery in cryopexy for retinal detachment, cyclo destructive procedures in refractory glaucoma, extraction of fragments within the vitreous cavity, cataract extraction, cryo destruction of lash follicles for trichiasis, and treatment of retinopathy of prematurity (ROP). | Quynh Hoang, Scientific Reviewer | | |--------------------------------------------------------------|--| | (PLEASE DO NOT WRITE BELOW THE LINE-CONTINUE ON ANOTHER PAGE | | IF NEEDED) Division of Ophthalmic Devices K9929.54 510(k) Number. Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use OR Over-The-Counter USE (Per 21 CFR 801.109 (Optional Format 1-2-96)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...