K030401 · Oasis Medical, Inc. · HNO · Jun 19, 2003 · Ophthalmic
Device Facts
Record ID
K030401
Device Name
DISPOSABLE M2-PE MICROKERATOME BLADES
Applicant
Oasis Medical, Inc.
Product Code
HNO · Ophthalmic
Decision Date
Jun 19, 2003
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 886.4370
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
The OASIS M2-PE Microkeratome Blades (Catalog #0415) are designed as replacement blades for the Moria M2 Microkeratome for lamellar resection of the cornea.
Device Story
Disposable M2-PE Microkeratome Blades are single-use, stainless steel replacement blades for the Moria M2 Microkeratome. Used by ophthalmologists in clinical settings for lamellar resection of the cornea. Device functions as a mechanical cutting tool; physical geometry and sharpness are designed to match the predicate device to ensure compatibility with the existing microkeratome system. Benefits include providing a sterile, sharp, disposable cutting edge for corneal surgery, reducing risks associated with blade reuse.
Clinical Evidence
No clinical data. Evidence consists of bench testing including dimensional equivalency, sharpness testing, and fit testing, supplemented by non-clinical testing on porcine eyes to verify performance in corneal lamellar resection.
Technological Characteristics
400 Series stainless steel blade; single-use; sterile (ethylene oxide to SAL 10^6 per EN 550); mechanical cutting principle; compatible with Moria M2 Microkeratome.
Indications for Use
Indicated for patients requiring lamellar resection of the cornea using the Moria M2 Microkeratome. Prescription use only.
Regulatory Classification
Identification
A keratome is an AC-powered or battery-powered device intended to shave tissue from sections of the cornea for a lamellar (partial thickness) transplant.
K022205 — DISPOSABLE N-PE MICROKERATOME BLADES · Oasis Medical, Inc. · Oct 3, 2002
K033236 — PRIZM KERATOME BLADE, MODEL MK8512M2 · Surgin Surgical Instrumentation, Inc. · Mar 26, 2004
K033457 — M2 COMPATIBLE MICROKERATOME BLADE · Micro Specialties, Inc. · May 25, 2004
K993122 — MSP M/K BLADE · Medical Sterile Products, Inc. · Mar 16, 2000
K032297 — DISPOSABLE N-PE MICKROKERATOME BLADES · Oasis Medical, Inc. · Aug 26, 2003
Submission Summary (Full Text)
{0}------------------------------------------------
KO30401
JUN 1 9 2003
Image /page/0/Picture/2 description: The image shows the word "OASIS" in a stylized font, with a palm tree above the letter "A". The letters are thick and bold, with the "O" being a complete circle and the "S" letters being incomplete circles. The palm tree is black and has several fronds extending from the top of the trunk.
510-528 S. Vermont Avenue Glendora, CA 91741 (626) 914-2891 FAX (626) 914 . 285
#### 510(k) Premarket Notification Summary Ref:
#### To: Document Control Clerk:
This is to notify you of the intention of OASIS Medical, Inc. to manufacture and market the following device:
Disposable M2-PE Microkeratome Blades
## Establishment Registration Number: 2083373
This 510(k) summary of safety and effectiveness for the OASIS Microkeratome Blades is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR §807.92, and follows the Office of Device Evaluation quidance concerning the presentation and content of a 510(k) summary.
- 1. Submitter's name, address, telephone number, contact person, and date the summary was prepared:
| a. | Applicant: | OASIS Medical, Inc.<br>512 South Vermont Avenue<br>Glendora, CA 91741 |
|----|-------------------|-----------------------------------------------------------------------|
| b. | Telephone Number: | (626) 852-5170 |
| | Facsimile Number: | (626) 914-9372 |
| c. | Contact Person: | Yvonne Fernandez- RA/QA Director |
- Date Summary Prepared: d. 01/27/03
- 2. Name of the Device, including trade name, the common or usual name, and the classification:
- Trade/Proprietary Name: Disposable M2-PE Microkeratome Blades a.
- b. Common/Usual Name: Keratome Blade
- Classification Name: C. Keratome (Blade Only) - 21CFR §886.4370
- ರ. Classification: Class I
- Product Code: e. 86 HNO
- f. Classification Panel: Ophthalmic
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the word "OASIS" in a stylized font. A palm tree is above the letters. The letters are bold and black. The background is white.
510-528 S. Vermont Avenue Glendora, CA 91741 (626) 914-2891 FAX (626) 01:12285
#### Identification of legally marketed devices to which equivalence is being 3. claimed:
The OASIS Medical, Inc. Disposable M2-PE Microkeratome Blades are substantially equivalent in design, material and function to the devices as marketed by:
| Company | Device | 510(k) Number |
|---------|------------------------|---------------|
| Moria | Moria M2 Microkeratome | K002191 |
#### 4. Description of the Device:
The OASIS Disposable M2-PE Microkeratome Blades are replacement stainless steel blades for the Moria M2 Microkeratome Blade. The Disposable M2-PE Microkeratome Blades are made of 400 Series Stainless Steel, packaged and sterilized using the same methods. The OASIS Disposable M2-PE Microkeratome Blades are single-use, disposable blades.
## Certification of Safety and Effectiveness:
When used according to the keratome manufacturer's instructions, there are no adverse safety indications the 0415 blade.
## Sterilization Methodology:
All blades are sterilized by exposure to ethylene oxide to a Sterilization Assurance Level (SAL) of 108 according a validated process in compliance with EN 550.
## Labeling:
The pouch will indicate OASIS name, address, product identification, lot number, sterilization notes, single use, and federal law statements.
#### 5. Intended Use for the Device:
The OASIS M2-PE Microkeratome Blades (Catalog #0415) are designed as replacement blades for the Moria M2 Microkeratome for lamellar resection of the cornea.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the word "OASIS" in a stylized font, with a palm tree above the letters "AS". The letters are thick and bold, with the "O" being a large circle and the "S" having a curved shape. The palm tree is black and has several fronds extending from the top of the trunk. The overall design is simple and eye-catching.
510-528 S. Vermont Avenue Glendora (A4174) (626) 914-289 i FAX (620) 11:2285
### Summary of the technological characteristics of the submitted device 6. compared to predicate devices:
M2-PE Blade - Summary of Technological Characteristics of Device Compared to Predicate Device' [Section 807.92(a)(6)] - K002191
| Characteristics | PD* - Moria M2 Blade | OASIS 0415 M2-PE Blade |
|-------------------|-------------------------------------------|------------------------|
| Intended Use | As indicated | Same |
| Target population | As indicated | Same |
| Performance | Compatibility with Moria M2 Microkeratome | Same |
| Blade Material | Low carbon stainless steel | Same |
| Biocompatibility | For Stainless Steel Blades | Same |
| Mechanical Safety | Assured | Same |
Performance Tests and Conclusions:
- Dimensional Equivalency Test Physical measurements of the predicate 1. device are substantially equivalent to the measurements of blades manufactured by OASIS Medical, Inc.
- 2. Sharpness Tests - Sharpness tests show that the OASIS M2-PE blades (0415) perform as well as the predicate device.
- 3. Fit into the Moria M2 Microkeratome has been tested and shown to be acceptable.
- র . Non-clinical testing on porcine eyes resulted in corneal lamellar sections equivalent to the predicate devices.
YO30401
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, with flowing lines suggesting movement or connection.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUN 1 9 2003
Oasis Medical, Inc. c/o Yvonne Fernandez RA/OA Director 512 S. Vermont Avenue Glendora, CA 91740
Re: K030401
Trade/Device Name: Disposable M2-PE (Precision Edge) Microkeratome Blade Regulation Number: 21 CFR 886.4370 Regulation Name: Keratome Regulatory Class: Class I Product Code: HNO Dated: February 05, 2003 Received: February 06, 2003
Dear Ms. Yvonne Fernandez:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{4}------------------------------------------------
## Page 2 – Ms. Yvonne Fernandez
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4613. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
A Kalpi Rosenthal
A. Ralph Rosenthal, M.D. Director Division of Ophthalmic and Ear, Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the word "OASIS" in a stylized font. A palm tree is placed above the letters "AI" in the word. The letters are bold and black, and the background is white. The font is unique, with the letters having a geometric and slightly angular design.
510-528 S. Vermont Avenue Glendora, CA 91741 (626) 914-2891 FAx : : : : : : : ) 914-2285
# OASIS Medical, Inc. Disposable M2-PE (Precision Edge) Microkeratome Blades Indications For Use
510(k) Number (if known):
K030401
Device Name:
Disposable M2-PE Microkeratome Blades
The OASIS Disposable M2-PE (Precision Edge) Microkeratome Blade (Catalog #0415) is designed as a replacement blade for the Moria M2 Microkeratome for lamellar resection of the cornea.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
이 이어 이어
Concurrence of CDRH, Office of Device Evaluation (ODE)
MKR Nicholas
Division Sign-Off Division of Ophthalmic Ear, Nose and Throat Devises
KO 30401 510(k) Number_
OR Over The Counter Use: Prescription Use: × (Per 21 CFR 801.109) (Optional Format 1-2-96)
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.