21 CFR 884.5210 — Pressure Wedge, Perianal, For Reduction Of Cesarean Delivery

Obstetrics/Gynecology (OB) · Part 884 Subpart F—Obstetrical and Gynecological Therapeutic Devices · § 884.5210

Identification

A pressure wedge for the reduction of cesarean delivery is a prescription device that provides external mechanical support to the perianal region during the labor and vaginal delivery process. External mechanical support of the perianal region is intended to help reduce the occurrence of cesarean delivery.

Classification Rationale

Class II (special controls). The special controls for this device are:

Product Codes

Product CodeDevice NameClassDevicesAttributes
PNUPressure Wedge, Perianal, For Reduction Of Cesarean Delivery21

Special Controls

PNU — Pressure Wedge, Perianal, For Reduction Of Cesarean Delivery

In combination with the general controls of the FD&C Act, the Pressure wedge for the reduction of cesarean delivery is subject to the following special controls:

De Novo Order DEN160005

PNU — Pressure Wedge, Perianal, For Reduction Of Cesarean Delivery

*Classification.* Class II (special controls). The special controls for this device are:(1) The patient contacting materials must be evaluated to be biocompatible. (2) Nonclinical performance data must demonstrate that the device will not break when subjected to the forces it will be exposed to during labor. (3) Performance data must validate the sterility of the device. (4) Performance data must support the shelf life of the device by demonstrating continued sterility and package integrity over the labeled shelf life. (5) Clinical performance data must be provided that characterizes the rate of skin/tissue trauma. (6) The labeling must include: (i) Specific instructions regarding the proper placement and use of the device. (ii) A shelf life.

eCFR

PNU — Pressure Wedge, Perianal, For Reduction Of Cesarean Delivery

(1) The patient contacting materials must be evaluated to be biocompatible. (2) Nonclinical performance data must demonstrate that the device will not break when subjected to the forces it will be exposed to during labor. (3) Performance data must validate the sterility of the device. (4) Performance data must support the shelf life of the device by demonstrating continued sterility and package integrity over the labeled shelf life. (5) Clinical performance data must be provided that characterizes the rate of skin/tissue trauma. (6) The labeling must include: (i) Specific instructions regarding the proper placement and use of the device. (ii) A shelf life.

Ecfr Llm

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...