KNA · Instrument, Manual, Specialized Obstetric-Gynecologic

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeKNA
Device NameInstrument, Manual, Specialized Obstetric-Gynecologic
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 58)

Showing 20 most recent of 58 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K130087PANPAC WORD/BARTHOLIN CATHETERPanpac Medical CorporationJan 10, 2014SESE
K102141COOK WORD BARTHOLIN GLAND CATHETER (FINAL TRADE NAME NOT YET DETERMINED)Cook Urological, Inc.May 6, 2011SESE
K093904GLENVEIGH VAGINAL TAMPONADE BALLOON CATHETERGlenveigh Surgical, LLCApr 14, 2010SESE
K082939COOK FETAL MEMBRANE MANIPULATOR, MODEL -FMM-122400Cook Urological, Inc.Sep 3, 2009SESE
K062438BAKRI POSTPARTUM BALLOON, MODEL J-SOS-100500Cook Ob/GynOct 27, 2006SESE
K060289EPISTAT, V-STAT, MODELS EPISTAT-001-01, V-STAT-001-01Frontline MedicalJul 7, 2006SESE
K013597TAMPONADE UTERINE BALLOON CATHETER SETCook Ob/GynApr 17, 2002SESE
K014248DND 202 MANUAL UROLOGICAL DIGITAL NEEDLE DRIVERUrogyn , Ltd.Mar 21, 2002SESE
K001590DND 101Urogyn , Ltd.Aug 2, 2000SESE
K990738DR. JAHANGER'S CUTTERM.S. Jahanger, MDOct 29, 1999SESE
K990045BERACLAMP, MODEL BC-1Poamax LLCMay 24, 1999SESE
K982464SCC-23 SAFETY CLAMP AND CUTTERWomen First Healthcare, Inc.Aug 11, 1998SESE
K980717UROMED SLING KITUromed Corp.May 22, 1998SESE
K980237GYNEX ENDOSPECULUMGynex Corp.Apr 8, 1998SESE
K972013NATIONAL MEDICAL HEALTHCARE CUSTOM OB/GYN KITS, TRAYS, OR PACKSNational Healthcare Mfg. Corp.Aug 26, 1997SESE
K971277SAFE-T-CLAMPTalon Medical, Ltd.May 20, 1997SESE
K952527BALLOON UTERINE STENTCook Urological, Inc.Jan 2, 1996SESE
K954619CORDGUARD IIUtah Medical Products, Inc.Dec 21, 1995SESE
K951081OB/GYN PACKSSterile Concepts, Inc.Nov 13, 1995SESE
K940907MADDEN SURGICAL THIMBLEKelley-Gilmer Medical Corp.Dec 29, 1994SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...