HDC · Tenaculum, Uterine

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeHDC
Device NameTenaculum, Uterine
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology
3rd-Party ReviewableYes

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 20)

RecordDevice NameApplicantDecision DateDecision
K223866Carevix™ Suction Cervical StabilizerAspivix SAJan 25, 2023SESE
K203820ASPIVIX v1.1 Cervical Suction TenaculumAspivix SAAug 17, 2021SESE
K142204Bioceptive Suction Cervical RetractorBioceptive, Inc.Dec 19, 2014SESE
K082349JARIT HULKA UTERINE TENACULUM FORCEPSJ. Jamner Surgical Instruments, Inc.Nov 21, 2008SESE
K073182GYN DISPOSABLES TENACULUM 356TGyn-Disposables, Inc.Nov 28, 2007SESE
K062563FEMTEN CERVICAL TENACULUMFem Suite, LLCMay 18, 2007SESE
K060573BURBANK TENACULUMVascular Control Systems, Inc.Apr 21, 2006SESE
K032585TRANSVAGINAL ULTRASOUND PROBE HOLDER SYSTEMRon-Tech Medical , Ltd.Jan 9, 2004SESE
K030078BURBANK TENACULUM, MODEL 09-0011-01Vascular Control Systems, Inc.Jan 24, 2003SESE
K001818UTERINE TENACLUM HOOKTowne Brothers (Pvt.), Ltd.Aug 30, 2000SESE
K992071TRANSVAGINAL ULTRASOUND PROBE HOLDER DEVICERon-Tech Medical , Ltd.Aug 27, 1999SESE
K980247GYNEX IRIS HOOK, GYNEX ANGLE HOOK, GYNEX EMMETT TENACULUMGynex Corp.Mar 17, 1998SESE
K930037ATRAUMATIC TENACULAThomasville Medical Assoc.Feb 24, 1994SESE
K910287OTT CERVICAL TENACULUMMarlo Surgical TechnologyFeb 28, 1991SESE
K894891IRRIGATOR STANDCommercial Products & Engineering Co.Aug 23, 1989SESE
K891350NEWPORT CERVICAL MANIPULATORSimpson/Basye, Inc.Mar 29, 1989SESE
K891349CAMPION CERVICAL HOOKSimpson/Basye, Inc.Mar 29, 1989SESE
K891347REID ENDOCERVICAL SPREADERSimpson/Basye, Inc.Mar 29, 1989SESE
K891033ATRAUMATIC TENACULAZinnanti Surgical Instruments, Inc.Mar 17, 1989SESE
K890379UTERINE TENTACULUMKinetic Medical ProductsFeb 13, 1989SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...