BRAINLAB STEREOTACTIC ARC

K992916 · Brainlab · HAW · Jan 11, 2000 · Neurology

Device Facts

Record IDK992916
Device NameBRAINLAB STEREOTACTIC ARC
ApplicantBrainlab
Product CodeHAW · Neurology
Decision DateJan 11, 2000
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4560
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The BrainLAB Stereotactic Arc system is an isocentric/target centered stereotactic arc for the adjustment of instrument trajectories and holding of instruments for neurosurgical applications in x,y,z directions and in azimuthal and declination angles requiring coordinate-accurate imaging-guided target localization and instrument guidance.

Device Story

BrainLAB Stereotactic Arc is an isocentric, target-centered mechanical frame for neurosurgical procedures. Device adjusts instrument trajectories and holds surgical instruments in x, y, z coordinates, as well as azimuthal and declination angles. Used in clinical neurosurgical settings by physicians to facilitate precise, image-guided instrument placement. System provides mechanical guidance for surgical tools to reach targets identified via imaging. Benefits include improved accuracy in trajectory alignment for neurosurgical interventions.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Isocentric/target-centered mechanical stereotactic arc. Designed for manual adjustment of instrument trajectories in x, y, z axes and angular orientations (azimuthal/declination).

Indications for Use

Indicated for neurosurgical applications requiring coordinate-accurate imaging-guided target localization and instrument guidance.

Regulatory Classification

Identification

A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or bird with three stylized wing segments. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 ## JAN 1 1 2000 Mr. Fotios Nisiropoulos Project Manager BrainLAB AG 100 Marine Parkway, Suite 305 Redwood City, California 94065 K992916 Re: Trade Name: BrainLab Stereotactic Arc Regulatory Class: II Product Code: HAW Dated: November 18, 1999 Received: November 26, 1999 Dear Mr. Nisiropoulos: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {1}------------------------------------------------ Page 2 -- Mr. Fotios Nisiropoulos This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Styt Rhodes James E. Dillard III Acting Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ **Page 1 of 1** 510(k) Number (if known): ×992916 Device Name: BrainLAB Stereotactic Arc Indications For Use: The BrainLAB Stereotactic Arc system is an isocentric/target centered stereotactic arc for the adjustment of instrument trajectories and holding of instruments for neurosurgical applications in x,y,z directions and in azimuthal and declination angles requiring coordinate-accurate imaging-guided target localization and instrument guidance. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) | | Concurrence of CDRH, Office of Device Evaluation (ODE) | |-----------------------------------------|--------------------------------------------------------| | (Division Sign-Off) | | | Division of General Restorative Devices | | | 510(k) Number | K992916 | | Prescription Use (Per 21 CFR 801.109) | <div style="text-align: left;">X</div> | | | OR | | | Over-The-Counter Use | | | (Optional Format I-2-96) |
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...