HHT · Spatula, Cervical, Cytological

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeHHT
Device NameSpatula, Cervical, Cytological
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology
3rd-Party ReviewableYes

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 73)

Showing 20 most recent of 73 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K182049exCellerator Cervical Collection DeviceExcell Company, LLCApr 25, 2019SESE
K153128Kolplast Cervical Sample Collection KitKolplast CI SAJan 13, 2017SESE
K141057DISPOSABLE CERVICAL BRUSHNingbo Hls Medical Products Co., Ltd.May 14, 2015SESE
K111681HISTOBRUSHPuritan Medical Products Company, LLCJan 19, 2012SESE
K083012PAPCONEOtto Bock Pur Life Science GmbHApr 9, 2009SESE
K081522BIO NUCLEAR DIAGNOSTICS (ENDO)CERVICAL SAMPLER FOR GYN CYTOLOGYBio Nuclear Diagnostics, Inc.Dec 5, 2008SESE
K072381SOFTPAP CERVICAL CELL COLLECTORCytocore, Inc.Jan 30, 2008SESE
K062433DIAMICS CERCOL CERVICAL SAMPLE COLLECTOR SYSTEMDiamics, Inc.Mar 16, 2007SESE
K043369CERVEX-BRUSH COMBIRovers Medical Devices B.V.Feb 2, 2005SESE
K042527SPATULA, CERVICAL, CYTOLOGICAL, MODEL 22-9107Medical Action Industries, Inc.Nov 8, 2004SESE
K041018DRG SOFTRELEASEDoctor'S Research Group, Inc.Oct 18, 2004SESE
K013258INPATH E2 COLLECTORMolecular DiagnosticsMay 31, 2002SESE
K002520ROVERS SPATULARovers Medical Devices B.V.Nov 13, 2000SESE
K001119ROVERS ENDOCERVEX-BRUSHRovers Medical Devices B.V.May 19, 2000SESE
K991595ORIBRUSH - WITH PROTECTIVE TIP - B001Orifice Medical ABJun 29, 1999SESE
K991593ORIBRUSH - STANDARD - B002Orifice Medical ABJun 29, 1999SESE
K983202HARWILL MEDICAL CERVITULA CERVICAL SPATULAHarwill Medical (Pty) , Ltd.Mar 15, 1999SESE
K983599SAFETEX CHLAMYDIA TRACHOMATIS SPECIMEN COLLECTION KITAndwin ScientificDec 11, 1998SESE
K983428SAFETEX CERVICAL SCRAPER (PLASTIC)Andwin ScientificNov 16, 1998SESE
K980356CERVICAL CYTOLOGY C-BRUSH MODEL CMB-1010Canadian Medical Brush, Inc.Apr 16, 1998SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...