MWA · System, Nucleic Acid Amplification, Mycobacterium Tuberculosis Complex

Microbiology · 21 CFR 866.3372 · Class 2

Overview

Product CodeMWA
Device NameSystem, Nucleic Acid Amplification, Mycobacterium Tuberculosis Complex
Regulation21 CFR 866.3372
Device ClassClass 2
Review PanelMicrobiology

Identification

Nucleic acid-based in vitro diagnostic devices for the detection of Mycobacterium tuberculosis complex in respiratory specimens are qualitative nucleic acid-based in vitro diagnostic devices intended to detect Mycobacterium tuberculosis complex nucleic acids extracted from human respiratory specimens. These devices are non-multiplexed and intended to be used as an aid in the diagnosis of pulmonary tuberculosis when used in conjunction with clinical and other laboratory findings. These devices do not include devices intended to detect the presence of organism mutations associated with drug resistance. Respiratory specimens may include sputum (induced or expectorated), bronchial specimens (e.g., bronchoalveolar lavage or bronchial aspirate), or tracheal aspirates.

Classification Rationale

Class II (special controls). The special control for this device is the FDA document entitled “Class II Special Controls Guideline: Nucleic Acid-Based In Vitro Diagnostic Devices for the Detection of Mycobacterium tuberculosis Complex in Respiratory Specimens.” For availability of the guideline document, see § 866.1(e).

Special Controls

*Classification.* Class II (special controls). The special control for this device is the FDA document entitled “Class II Special Controls Guideline: Nucleic Acid-Based In Vitro Diagnostic Devices for the Detection of*Mycobacterium tuberculosis* Complex in Respiratory Specimens.” For availability of the guideline document, see § 866.1(e).

Recent Cleared Devices (2 of 2)

RecordDevice NameApplicantDecision DateDecision
P940040AMPLICOR (TM) MYCOBACTERIUM TUBERCULOSIS TESTRoche Molecular Systems, Inc.Nov 26, 1996APWD
P940034GEN-PROBE(R) AMPLIFIED MYCOBACTERIUM TUBERCULOSIS DIRECT TEST (MTD TEST)Gen-Probe, Inc.Dec 15, 1995APRL

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...