JZW · Nephelometer

Immunology · 21 CFR 866.4540 · Class 1

Overview

Product CodeJZW
Device NameNephelometer
Regulation21 CFR 866.4540
Device ClassClass 1
Review PanelImmunology

Identification

Immunonephelometer equipment for clinical use with its electrical power supply is a device that measures light scattering from antigen-antibody complexes. The concentration of these complexes may be measured by means of reflected light. A beam of light passed through a solution is scattered by the particles in suspension. The amount of light is detected by a photodetector, which converts light energy into electrical energy. The amount of electrical energy registers on a readout system such as a digital voltmeter or a recording chart. This electrical readout is called the light-scattering value and is used to measure the concentration of antigen-antibody complexes. This generic type of device includes devices with various kinds of light sources, such as laser equipment.

Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 866.9.

Recent Cleared Devices (11 of 11)

RecordDevice NameApplicantDecision DateDecision
K001647BN PROSPEC SYSTEMDade Behring, Inc.Sep 26, 2000SESE
K761234BEHRING LASER NEPHELOMETERBehring Diagnostics, Inc.Jun 7, 1990SESE
K892223BEHRING NEPHELOMETER 100Behring Diagnostics, Inc.May 4, 1989SESE
K873407RRT SYSTEM LASER REFLECTOMETER ANALYZERIncstar Corp.Sep 23, 1987SESE
K873401TURBOXUnipath , Ltd.Sep 23, 1987SESE
K801949BCM-302 COLLIMATING CONE & COMPENSATINB C Medical , Ltd.Oct 3, 1980SESE
K801391DISC 120 TRANSPORTERTravenol Laboratories, S.A.Jul 14, 1980SESE
K792014LANCER L-INA BUFFER, POLYMER, WASH SOLUSherwood Medical IndustriesNov 13, 1979SESE
K781006IMMUNOCHEMISTRY SYS. MANUAL MODEBeckman Instruments, Inc.Aug 31, 1978SESE
K761236ANTISERUM HUMAN (PRO.) NEPHELOMETRIC GR.Behring Diagnostics, Inc.Dec 30, 1976SESE
K761235LASER STANDARD SERUMBehring Diagnostics, Inc.Dec 30, 1976SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...