JZT · Fluorometer

Immunology · 21 CFR 866.4520 · Class 1

Overview

Product CodeJZT
Device NameFluorometer
Regulation21 CFR 866.4520
Device ClassClass 1
Review PanelImmunology

Identification

Immunofluorometer equipment for clinical use with its electrical power supply is a device used to measure the fluorescence of fluorochrome-labeled antigen-antibody complexes. The concentration of these complexes may be measured by means of reflected light. A beam of light is passed through a solution in which a fluorochrome has been selectively attached to serum protein antibody molecules in suspension. The amount of light emitted by the fluorochrome label is detected by a photodetector, which converts light energy into electrical energy. The amount of electrical energy registers on a readout system such as a digital voltmeter or a recording chart. This electrical readout is called the fluorescence value and is used to measure the concentration of antigen-antibody complexes.

Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 866.9.

Recent Cleared Devices (14 of 14)

RecordDevice NameApplicantDecision DateDecision
K962499ZYMMUNE AUTOREADER-F FLUORESCENCE MICROPLATE READERBartels, Inc.Sep 5, 1996SESE
K883349QLIA IMMUNOCHEMISTRY SYSTEMBd Becton Dickinson Vacutainer Systems PreanalyticSep 7, 1988SESE
K882677STAT-20 FLUOROMETERWeaver MedicalJul 12, 1988SESE
K864699FLUORESCENCE CONCENTRATION ANALYZER (FCA)Pandex Laboratories, Inc.Dec 22, 1986SESE
K863434THE FIAX 5000 FLUOROMETERWhittaker Bioproducts, Inc.Oct 29, 1986SESE
K862674PHOTON ELITE/AUTOMATED RANDOM ACCESS IM/CH SYSTEMHybritech, Inc.Aug 15, 1986SESE
K852240SMS, SCREEN MACHINE SYSTEMPandex Laboratories, Inc.Jun 11, 1985SESE
K842049FLUOROSKANFlow Laboratories, Inc.Dec 3, 1984SESE
K843356FIAX 100 FLUOROMETERIntl. Diagnostic TechnologySep 17, 1984SESE
K834070IMMPULSE SYSTEMParagon Diagnostics, Inc.Mar 23, 1984SESE
K831870ALLERGENETICS FLUORO-FAST READERAxonics, Inc.Aug 12, 1983SESE
K800698AUTOFLUOR SYSTEMCalifornia Immuno Diagnostic, Inc.May 28, 1980SESE
K782150FLUROMETER, DADEDade, Baxter Travenol Diagnostics, Inc.Feb 15, 1979SESE
K770662VIEWER, FLUOROMETIC, MODEL 721Corning Medical & ScientificApr 15, 1977SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...