GOK · Antisera, Hai (Including Hai Control), Rubella

Microbiology · 21 CFR 866.3510 · Class 2

Overview

Product CodeGOK
Device NameAntisera, Hai (Including Hai Control), Rubella
Regulation21 CFR 866.3510
Device ClassClass 2
Review PanelMicrobiology
3rd-Party ReviewableYes

Identification

Rubella virus serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to rubella virus in serum. The identification aids in the diagnosis of rubella (German measles) or confirmation of a person's immune status from past infections or immunizations and provides epidemiological information on German measles. Newborns infected in the uterus with rubella virus may be born with multiple congenital defects (rubella syndrome).

Classification Rationale

Class II. The special controls for this device are:

Special Controls

*Classification.* Class II. The special controls for this device are:(1) National Committee for Clinical Laboratory Standards': (i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation and Performance Criteria for Multiple Component Test Products, Speciment Handling, and Use of the Test Products in the Clinical Laboratory, October 1997,” (ii) 1/LA18 “Specifications for Immunological Testing for Infectious Diseases, December 1994,” (iii) D13 “Agglutination Characteristics, Methodology, Limitations, and Clinical Validation, October 1993,” (iv) EP5 “Evaluation of Precision Performance of Clinical Chemistry Devices, February 1999,” and (v) EP10 “Preliminary Evaluation of the Linearity of Quantitive Clinical Laboratory Methods, May 1998,” (2) Centers for Disease Control's: (i) Low Titer Rubella Standard, (ii) Reference Panel of Well Characterized Rubella Sera, and (3) World Health Organization's International Rubella Standard.

Recent Cleared Devices (11 of 11)

RecordDevice NameApplicantDecision DateDecision
K832228RUBASCAN LATEX CARD TESTBd Becton Dickinson Vacutainer Systems PreanalyticSep 29, 1983SESE
K810835RUBAZYME - MAbbott LaboratoriesMay 5, 1981SESE
K792635ANTIBODY TO RUBELLA VIRUSElectro-Nucleonics Laboratories, Inc.Mar 19, 1980SESE
K792133RUBELISA TEST KITMicrobiological Assoc.Jan 11, 1980SESE
K790122RUBANONOrganon, Inc.Feb 15, 1979SESE
K781638RUBINDEX*DIRECT SYSTEMOrtho Diagnostics, Inc.Dec 20, 1978SESE
K781392CYTOMEGILISH TEST KITMicrobiological Assoc.Oct 24, 1978SESE
K780063RUBENOSTICONOrganon, Inc.Jan 20, 1978SESE
K780010GOAT ANTI-RUBELLA ANTISERANortheast Biomedical Labs., Inc.Jan 20, 1978SESE
K771957RUBELLA HEMAGGLUTINATION REAGENT KITFlow Laboratories, Inc.Oct 28, 1977SESE
K771956HUMAN O BUFFERFlow Laboratories, Inc.Oct 28, 1977SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...