Identification

Histoplasma capsulatum serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to Histoplasma capsulatum in serum. Additionally, some of these reagents consist of Histoplasma capsulatum antisera conjugated with a fluorescent dye (immunofluorescent reagents) used to identify Histoplasma capsulatum from clinical specimens or cultured isolates derived from clinical specimens. The identification aids in the diagnosis of histoplasmosis caused by this fungus belonging to the genus Histoplasma and provides epidemiological information on the diseases caused by this fungus. Histoplasmosis usually is a mild and often asymptomatic respiratory infection, but in a small number of infected individuals the lesions may spread to practically all tissues and organs.

Classification Rationale

Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

Recent Cleared Devices (9 of 9)

RecordDevice NameApplicantDecision DateDecision
K792694NEGATIVE CONTROL SERUMMeridian Diagnostics, Inc.Jan 24, 1980SESE
K792692IMMUNODIFFUSION BAND INTENSIFYING FLUIDMeridian Diagnostics, Inc.Jan 24, 1980SESE
K792718HISTOPLASMA CAPSULATUM, ANTISERUMMeridian Diagnostics, Inc.Jan 17, 1980SESE
K792679HISTOPLASMA CAPSULATUM, ANTISERUMMeridian Diagnostics, Inc.Jan 17, 1980SESE
K791395ANTI-HISTOPLASMA SERUM #CF10025XImmuno-Mycologics, Inc.Aug 16, 1979SESE
K791392ANTI-HISTOPLASMA SERUM #CF10026XImmuno-Mycologics, Inc.Aug 16, 1979SESE
K791390ANTI-BLASTOMYCES SERUM #CF10027XImmuno-Mycologics, Inc.Aug 16, 1979SESE
K760832ANTI-HISTOPLASMA CONTROL SERUM (YEAST)I M, Inc.Nov 1, 1976SESE
K760831ANTI-HISTOPLASMA CONTROL SERUM(MYCELIAL)I M, Inc.Nov 1, 1976SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...