QRC · Non-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation

Gastroenterology, Urology · 21 CFR 876.5026 · Class 2

Overview

Product CodeQRC
Device NameNon-Implanted Electrical Stimulation Device For Management Of Premature Ejaculation
Regulation21 CFR 876.5026
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

A non-implanted electrical stimulation device for management of premature ejaculation is intended to be used in patients with premature ejaculation by delivery of electrical stimulation to the perineal muscles and nerves.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

In combination with general controls of the Food Drug & Cosmetic Act, the non-implanted electrical stimulation device for management of premature ejaculation is subject to the following special controls:

*Classification.* Class II (special controls). The special controls for this device are:(1) The device must be demonstrated to be biocompatible. (2) Performance testing must demonstrate the electromagnetic compatibility, electrical safety, and thermal safety of the device. (3) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use. The following performance characteristics must be tested: (i) Mechanical performance; (ii) Electrical stimulation parameters; and (iii) Battery performance. (4) Performance testing must support shelf life by demonstrating continued device functionality over the identified shelf life. (5) Software verification, validation, and hazard analysis must be performed. (6) Labeling must include: (i) Specific instructions regarding safe placement and correct use of the device; (ii) Warning(s) against use by patients with active implanted medical devices; and (iii) A shelf life.

Recent Cleared Devices (4 of 4)

RecordDevice NameApplicantDecision DateDecision
K252809in2 Smart (in2S)Virility Medical , Ltd.Apr 6, 2026SESE
K241897MORMorari, Inc.Feb 11, 2025SESE
K223595vPATCHVirility Medical , Ltd.May 1, 2023SESE
DEN210012vPatchVirility MedicalNov 23, 2021DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...