KNX · Collector, Urine, (And Accessories) For Indwelling Catheter

Gastroenterology, Urology · 21 CFR 876.5250 · Class 2

Overview

Product CodeKNX
Device NameCollector, Urine, (And Accessories) For Indwelling Catheter
Regulation21 CFR 876.5250
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

A urine collector and accessories is a device intended to collect urine. The device and accessories consist of tubing, a suitable receptacle, connectors, mechanical supports, and may include a means to prevent the backflow of urine or ascent of infection. The two kinds of urine collectors are:(1) A urine collector and accessories intended to be connected to an indwelling catheter, which includes the urinary drainage collection kit and the closed urine drainage system and drainage bag; and (2) A urine collector and accessories not intended to be connected to an indwelling catheter, which includes the corrugated rubber sheath, pediatric urine collector, leg bag for external use, urosheath type incontinence device, and the paste-on device for incontinence.

Classification Rationale

(1) Class II (special controls) for a urine collector and accessories intended to be connected to an indwelling catheter. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.(2) Class I (general controls). For a urine collector and accessories not intended to be connected to an indwelling catheter, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Special Controls

*Classification* —(1)*Class II (special controls) for a urine collector and accessories intended to be connected to an indwelling catheter.* The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.(2) *Class I (general controls).* For a urine collector and accessories not intended to be connected to an indwelling catheter, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Recent Cleared Devices (20 of 206)

Showing 20 most recent of 206 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K110518IBAGFuture Path Medical, LLCJun 24, 2011SESE
K9733644L DRAINAGE BAG, 4L BAG FOR PERITONEAL DIALYSIS, 4L URINARY DRAINAGE BAGMaersk Medical A/SMar 17, 1998SESE
K972887MEDLINE PREMIUM LEG BAG, MEDLINE FABRIC BAC LEG BAG, MEDLINE URINARY LEG BAGMedline Industries, Inc.Dec 11, 1997SESE
K971271BESECURE EXTERNAL URINARY COLLECTION SYSTEMUrology Research Intl., Inc.Aug 18, 1997SESE
K971929AMSINO URINARY LEG BAGAmsino Intl., Inc.Aug 6, 1997SESE
K971764WELCON HUE-VU URINARY DRAINAGE BAGWelcon, Inc.Jul 29, 1997SESE
K964690LIBERTY VALVECleveland Medical Devices, Inc.Mar 21, 1997SESE
K964745AMSINO URINARY DRAINAGE BAGAmsino Intl., Inc.Mar 18, 1997SESE
K962652URINARY DRAINAGE BAG, (REORDER NO. 0749 - PRODUCT NO. 900-749)Customed, Inc.Oct 4, 1996SESE
K960949PROSYS BEDSIDE DRAINAGE BAG (STERILE) MODEL 650167Bristol-Myers SquibbApr 19, 1996SESE
K952208PROSYS LEG BAGConvatec, A Division of E.R. Squibb & SonsAug 15, 1995SESE
K944377ORION'S URINARY DRAINAGE SETRegulatory & Marketing Services, Inc.Dec 6, 1994SESE
K944236NEEDLELESS URINE SAMPLING PORTKendall Healthcare Products Co. Div.Of Tyco HealthNov 16, 1994SESE
K940206BARD URINE COLLECTION PRODUCTS MODIFICATIONC.R. Bard, Inc.Sep 16, 1994SESE
K941447SIMPLA S4, S5, S7Simpla Plastics , Ltd.Jul 18, 1994SESE
K935557URINARY DRAINAGE BAGPuritas Health Care, Inc.Mar 7, 1994SESE
K931459KENGUARD URINARY DRAINAGE BAG W/ANTIREFLUX CHAMBERKendall Healthcare Products Co. Div.Of Tyco HealthJun 14, 1993SESE
K925067SIMPLA TRIDENT LEG BAG + SIMPLA S6 BAGSimport Plastics, Ltd.Jun 10, 1993SESE
K926570HOLLISTER(R) BEDSIDE DRAINAGE COLLECTION SYST 9878Hollister, Inc.May 21, 1993SESE
K921024URO-TOTE LEG BAGNeotech Products, Inc.Sep 2, 1992SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...