KDJ · Set, Administration, For Peritoneal Dialysis, Disposable

Gastroenterology, Urology · 21 CFR 876.5630 · Class 2

Overview

Product CodeKDJ
Device NameSet, Administration, For Peritoneal Dialysis, Disposable
Regulation21 CFR 876.5630
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.

Classification Rationale

Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Special Controls

*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.

Recent Cleared Devices (20 of 113)

Showing 20 most recent of 113 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K250404stay•safe® catheter extension set with Safe- Lock, 12 inch; stay•safe® catheter extension set with Luer-Lock, 6 inch; stay•safe® catheter extension set with Luer-Lock, 12 inch; stay•safe® catheter extension set with Luer-Lock, 18 inch; stay•safe® to Luer-Lock Adapter, 4 inchFresenius Medical Care Renal Therapies Group, LLCApr 3, 2025SESE
K231849MiniCap Extended Life PD Transfer Set with Twist Clamp - Code 5C4482A; MiniCap Extended Life PD Transfer Set with Twist Clamp - Extra Short - Code 5C4483Baxter HealthcareMar 12, 2024SESE
K21401615L Cycler Drainage BagBaxter Healthcare CorporationMar 18, 2022SESE
K192705MiniCap Extended Life PD Transfer SetsBaxter HealthcareOct 25, 2019SESE
K173593stay•safe catheter extension set with Safe-Lock, 12 inch, stay•safe catheter extension set with Luer-Lock, 6 inch, stay•safe catheter extension set with Luer-Lock, 12 inch, stay•safe catheter extension set with Luer-Lock, 18 inch, stay•safe to Luer-Lock adapter, 4 inchFresenius Medical Care Renal Therapies Group, LLCMay 21, 2018SESE
K173651Multiple Tubing Segment Set with stay safe PIN Connectors, stay safe Drain SetFresenius Medical Care Renal Therapies Group, LLCFeb 14, 2018SESE
K173363Cycler Drain Bag SetFresenius Medical Care Renal Therapies Group, LLCJan 24, 2018SESE
K151620Firefly Peritoneal Dialysis Connector Disinfection SystemPuracath Medical, Inc.Jan 20, 2016SESE
K152675EXTENDED LIFE CAPD TRANSFER SET, PERITONEAL DIALYSIS TITANIUM CATHETER ADAPTER AND LOCKING CAP FOR TITANIUM CATHETER ADAPTERBaxter HealthcareOct 29, 2015SESE
K152129FlexiCap Disconnect Cap with Povidone-Iodine Solution, MiniCap with Povidone-Iodine SolutionBaxter Healthcare CorporationOct 29, 2015SESE
K124024APD LUER-LOCK ADAPTERFresensius Medical Care North AmericaSep 19, 2013SESE
K083542FRESENIUS STERILE STAY SAFE CAPFresenius Medical Care North AmericaDec 29, 2008SESE
K042900K.E.P. CONNECTOR AND CLIPK.E.P., LLCNov 5, 2004SESE
K041792FRESENIUS STAYSAFE PATIENT CONNECTORS, MODEL 050-87211Fresenius Medical Care North AmericaSep 24, 2004SESE
K031676HOMECHOICE APD SET WITH LINEO CONNECTOR, MODELS 5C4469Q, 5C4468Q, 5C4531Q, 5C8302Q, 5C4599QBaxter Healthcare CorpNov 20, 2003SESE
K022412FRESENIUS CAPD STAY.SAFE DISPOSABLE ADMINISTRATION SETS WITH STAY.SAFE CONNECTORFresenius Medical Care North AmericaMar 5, 2003SESE
K974387PDM3 DISINFECTION SYSTEM FOR PERITONEAL DIALYSIS EXCHANGES, PATIENT TRANSFER SET PTS102, CAP, HIGH TEMPERATUREMicrowave Medical Systems, Inc.Sep 1, 1999SESE
K972579HIGH DOSE DISCONNECT CAP AND MINICAP WITH POVIDONE-IODINE, HIGH DOSE DISCONNECT CAP WITH POVIDONE-IODINEBaxter Healthcare CorpOct 1, 1997SESE
K972731NEO-CARE PERITONEAL DIALYSIS ADMINISTRATION SETKlein-Baker Medical, Inc.Sep 29, 1997SESE
K963668MEDISYSTEMS PERITONEAL DIALYSIS SETSMedisystems Corp.Aug 15, 1997SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...