CORPAK MEDSYSTEMS CRUZ CATHETER FOR PERITONEAL DIALYSIS
Device Facts
| Record ID | K964514 |
|---|---|
| Device Name | CORPAK MEDSYSTEMS CRUZ CATHETER FOR PERITONEAL DIALYSIS |
| Applicant | Corpak, Inc. |
| Product Code | FKO · Gastroenterology, Urology |
| Decision Date | Jun 26, 1998 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.5630 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The indicated use for the Cruz Catheter is for patients requiring a catheter for long term peritoneal dialysis.
Device Story
Cruz Peritoneal Dialysis Catheter is a medical device designed for long-term peritoneal dialysis access. It is intended for use by clinicians in a healthcare setting to facilitate the dialysis process. The device is implanted to provide a conduit for the exchange of dialysate solution within the peritoneal cavity. By enabling chronic access, it supports the management of patients with end-stage renal disease requiring peritoneal dialysis therapy.
Clinical Evidence
No clinical data provided; substantial equivalence determination based on device description and intended use.
Technological Characteristics
Peritoneal dialysis catheter designed for long-term implantation. Specific materials and dimensions not detailed in the provided text.
Indications for Use
Indicated for patients requiring long-term peritoneal dialysis.
Regulatory Classification
Identification
(1) A peritoneal dialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set for peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the dialysate is instilled into the patient's peritoneal cavity, it is allowed to dwell there so that undesirable substances from the patient's blood pass through the lining membrane of the peritoneal cavity into this dialysate. These substances are then removed when the dialysate is drained from the patient. The peritoneal dialysis system may regulate and monitor the dialysate temperature, volume, and delivery rate together with the time course of each cycle of filling, dwell time, and draining of the peritoneal cavity or manual controls may be used. This generic device includes the semiautomatic and the automatic peritoneal delivery system.(2) The peritoneal access device is a flexible tube that is implanted through the abdominal wall into the peritoneal cavity and that may have attached cuffs to provide anchoring and a skin seal. The device is either a single use peritioneal catheter, intended to remain in the peritoneal cavity for less than 30 days, or a long term peritoneal catheter. Accessories include stylets and trocars to aid in the insertion of the catheter and an obturator to maintain the patency of the surgical fistula in the abdominal wall between treatments. (3) The disposable administration set for peritoneal dialysis consists of tubing, an optional reservoir bag, and appropriate connectors. It may include a peritoneal dialysate filter to trap and remove contaminating particles. (4) The source of dialysate may be sterile prepackaged dialysate (for semiautomatic peritoneal dialysate delivery systems or “cycler systems”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal dialysate delivery systems or “reverse osmosis” systems). Prepackaged dialysate intended for use with either of the peritoneal dialysate delivery systems is regulated by FDA as a drug.
Special Controls
*Classification.* Class II (special controls). The following accessories are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9: A catheter finger grip that is non-patient contacting and intended for single use with a peritoneal catheter; a continuous ambulatory peritoneal dialysis (CAPD) belt; and a catheter stand that does not include weigh scales.
Related Devices
- K993149 — PERITONEAL DIALYSIS CATHETERS AND ADAPTERS · Medionics International, Inc. · Apr 28, 2000
- K992907 — INTRADUCER · Taut, Inc. · Oct 5, 1999
- K053123 — PD CATH · Med-Conduit, Inc. · Mar 29, 2006
- K963668 — MEDISYSTEMS PERITONEAL DIALYSIS SETS · Medisystems Corp. · Aug 15, 1997
- K982326 — MEDI-TECH DIALYSIS CATHETER GASTROENTEROLOGY · Boston Scientific Corp · Jul 12, 1999