BSS · Tube, Nasogastric

Gastroenterology, Urology · 21 CFR 876.5980 · Class 2

Overview

Product CodeBSS
Device NameTube, Nasogastric
Regulation21 CFR 876.5980
Device ClassClass 2
Review PanelGastroenterology, Urology
3rd-Party ReviewableYes

Identification

A gastrointestinal tube and accessories is a device that consists of flexible or semi-rigid tubing used for instilling fluids into, withdrawing fluids from, splinting, or suppressing bleeding of the alimentary tract. This device may incorporate an integral inflatable balloon for retention or hemostasis. This generic type of device includes the hemostatic bag, irrigation and aspiration catheter (gastric, colonic, etc.), rectal catheter, sterile infant gavage set, gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with mercury weight balloon for intestinal intubation or decompression, and gastro-urological irrigation tray (for gastrological use).

Classification Rationale

(1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

Special Controls

*Classification.* (1) Class II (special controls). The barium enema retention catheter and tip with or without a bag that is a gastrointestinal tube and accessory or a gastronomy tube holder accessory is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 876.9.

Recent Cleared Devices (13 of 13)

RecordDevice NameApplicantDecision DateDecision
K142483TurboSEAL Nasogastric Aspiration TubeTurboseal, L.P.Dec 19, 2014SESE
K051480ENTERAL FEEDING TUBEBiosearch Medical Products, Inc.Oct 12, 2005SESE
K984629MOSS TUBES, INC. NASAL TUBE - MARK IVMoss Tubes, Inc.Mar 2, 1999SESE
K961711ASPISAFE GASTRIC TUBEB.Braun Medical, Inc.Jun 11, 1997SESE
K933596GASTRIC, CATHETER, IRRIGATION & ASPIRATIONPolamedco, Inc.Feb 13, 1995SESE
K930510RADIUS ENTERAL FEEDING TUBERadius Intl., Inc.Feb 1, 1995SESE
K935688AN-10S ANDERSEN TUBE WITH STYLETH.W. Andersen Products, Inc.Dec 30, 1994SESE
K934348TRI-MED QUICK-STEP GASTRIC LAVAGE TUBE SIZES 18FR, 22FR, 32FRTri-Med Specialties, Inc.Dec 23, 1994SESE
K905573XEMEX ENTERAL NUTRITION CATHETER NASOGAS. TYPE AZeon Medical Corp.Jun 19, 1991SESE
K910479ARGYLE POLYURETHANE SALEM SUMP TUBESherwood Medical Co.Apr 19, 1991SESE
K894870WILTEK NASAL BILIARY DRAINAGE SETWiltek Medical, Inc.Dec 21, 1989SESE
K891187TECNOL NASO-GASTRIC TUBE HOLDERTecnol New Jersey Wound Care, Inc.May 30, 1989SESE
K791531FLEXIFLO ENTERAL PUMP SETAbbott LaboratoriesSep 12, 1979SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...