LESE STENTS SETS
Device Facts
| Record ID | K952513 |
|---|---|
| Device Name | LESE STENTS SETS |
| Applicant | Cook Urological, Inc. |
| Product Code | FAD · Gastroenterology, Urology |
| Decision Date | Jun 10, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.4620 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The LSe Stent Sets are used for temporary internal drainage from the ureteropelvic junction to the bladder.
Device Story
Ureteral stent for temporary internal drainage from ureteropelvic junction to bladder; ion implantation treatment applied to reduce surface friction and enhance surface energy; used by urologists in clinical settings; provides drainage to relieve obstruction or facilitate healing; biocompatible materials ensure safety during indwelling period.
Clinical Evidence
Bench testing only. Biocompatibility testing performed on polyurethane, silicone, and vinyl materials; results met requirements. Stainless steel and TFE biocompatibility assured via established medical use.
Technological Characteristics
Materials: stainless steel, TFE, polypropylene, polyurethane, silicone, vinyl. Surface modification: ion implantation for reduced friction/enhanced surface energy. Sterilization: consistent with existing marketed Cook Urological devices.
Indications for Use
Indicated for temporary internal drainage from the ureteropelvic junction to the bladder in patients requiring ureteral stenting.
Regulatory Classification
Identification
A ureteral stent is a tube-like implanted device that is inserted into the ureter to provide ureteral rigidity and allow the passage of urine. The device may have finger-like protrusions or hooked ends to keep the tube in place. It is used in the treatment of ureteral injuries and ureteral obstruction.
Predicate Devices
- Cook Urological® Ureteral and Urethral Stents (preamendment)
- Cook Urological® EchoSight® Sof-Flex® Stents
- Cook Urological® SlipCoat™ Stents
Related Devices
- K961446 — AQ HYDROPHILIC STENT · Cook Urological, Inc. · May 28, 1996
- K243830 — Disposable ureteral stent · Shenzhen Trious Medical Technology Co., Ltd. · May 14, 2025
- K082805 — PAGUAMEDICINA STRUCTURAL HYDROGEL PEDIATRIC URETERAL STENT, MODEL NP330-XXX · Q Urological Corporation · Jan 20, 2010
- K974541 — MODIFIED URETERAL INDWELLING CATHETER/STENT · Boston Scientific Corp · Feb 9, 1998
- K960148 — CIRCON-SURGITEK CLASSIC DOUBLE PIGTAIL URETERAL STENT · Cabot Medical Corp. · Mar 25, 1996