EsophyX® Z Device with SerosaFuse Fasteners and Accessories

K160960 · Endogastric Solutions, Inc. · ODE · May 1, 2016 · Gastroenterology, Urology

Device Facts

Record IDK160960
Device NameEsophyX® Z Device with SerosaFuse Fasteners and Accessories
ApplicantEndogastric Solutions, Inc.
Product CodeODE · Gastroenterology, Urology
Decision DateMay 1, 2016
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The EndoGastric Solutions EsophyX Z Device with SerosaFuse Fasteners and Accessories is indicated for use in transoral tissue approximation, full thickness plication and ligation in the GI tract and is indicated for the treatment of symptomatic chronic gastroesophageal reflux disease in patients who require and respond to pharmacological therapy. It is also indicated to narrow the gastroesophageal junction and reduce hiatal hernia ≤ 2cm in size in patients with symptomatic chronic gastroesophageal reflux disease.

Device Story

EsophyX Z Device is a single-use, flexible, mechanical fastener delivery system for transoral incisionless fundoplication. Device operates via external mechanical controls; requires a separate, independently operated endoscope for visualization through a central lumen. Operator captures tissue at the gastroesophageal junction; deploys polypropylene H-shaped fasteners to create permanent surgical fundoplication. Used in clinical settings by physicians. Device narrows gastroesophageal junction and reduces hiatal hernias ≤ 2cm to treat chronic GERD. Benefits include restoration of valvular functionality and reduction of reflux symptoms without surgical incisions.

Clinical Evidence

No clinical data. Substantial equivalence supported by bench testing, including dimensional, mechanical, and performance verification. Biocompatibility testing (cytotoxicity, sensitization, irritation/intracutaneous reactivity) performed for new patient-contacting materials. Cadaver and animal labs conducted to verify fastener deployment.

Technological Characteristics

Flexible shaft, mechanical fastener delivery system. Materials: Polypropylene fasteners; biocompatible plastics with colorants. Energy: None (purely mechanical). Connectivity: None. Sterilization: Ethylene Oxide (EO). Form factor: Transoral, flexible shaft with external mechanical controls. Software: None.

Indications for Use

Indicated for patients with symptomatic chronic gastroesophageal reflux disease (GERD) who require and respond to pharmacological therapy; also indicated for narrowing the gastroesophageal junction and reducing hiatal hernias ≤ 2cm.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle or bird-like figure, composed of three overlapping profiles facing to the right. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 May 1, 2016 EndoGastric Solutions, Inc. Steven J. Hoffman Corporate Compliance Officer 18109 NE 76th Street. Suite 100 Redmond, WA 98052 Re: K160960 > Trade/Device Name: EsophyX® Z Device with SerosaFuse Fasteners and Accessories Regulation Number: 21 CFR §876.1500 Regulation Name: Endoscope and Accessories Regulatory Class: II Product Code: ODE Dated: April 1, 2016 Received: April 5, 2016 Dear Steven J. Hoffman: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. {1}------------------------------------------------ You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Benjamin R. Fisher -S Benjamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known) K160960 Device Name EsophyX® Z Device with SerosaFuse Fasteners and Accessories Indications for Use (Describe) The EndoGastric Solutions EsophyX Z Device with SerosaFuse is indicated for use in transoral tissue approximation, full thickness plication and ligation in the GI tract and is indicated for the treatment of symptomatic chronic gastroesophageal reflux disease in patients who require and respond to pharmacological therapy. It is also indicated to narrow the gastroesophageal junction and reduce hiatal hernia ≤ 2cm in size in patients with symptomatic chronic gastroesophageal reflux disease. | Type of Use (Select one or both, as applicable) | | |------------------------------------------------------------------------------------|-----------------------------------------------| | <span style="font-size:10px">☑</span> Prescription Use (Part 21 CFR 801 Subpart D) | ☐ Over-The-Counter Use (21 CFR 801 Subpart C) | #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ ## Section 1. Premarket Notification 510(k) Summary This summary of 510(k) safety and effectiveness information is submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92. #### 510(k) Number: K160960 #### Applicant Information [807.92(a)(1)]: | Date Prepared: | April 27, 2016 | |-------------------|--------------------------------------------------| | Name: | EndoGastric Solutions, Inc. | | Address: | 18109 NE 76th St. Suite 100<br>Redmond, WA 98052 | | Phone: | 425-307-9200 | | Fax: | 425-307-9201 | | Contact Person: | Steven J Hoffman | | Phone Number: | 425.307.9226 | | Office: | 425.307.9226 | | Facsimile Number: | 425.307.9201 | #### Device Information [807.92(a)(2)]: | Device Trade Name: | EsophyX® Z Device with SerosaFuse Fasteners and Accessories | |---------------------------|---------------------------------------------------------------| | Common Name: | Endoscopic Clip Applier, Implantable Fastener and Accessories | | Classification Name(s): | Endoscope and Accessories | | Product Code/ Regulation: | ODE / 21 CFR 876.1500 | | Classification: | Class II | ### Predicate Device(s) [807.92(a)(3)]: The predicate device is the EndoGastric Solutions EsophyX Z System cleared via 510(k) # K143645. #### Device Description: [807.92(a)(4)]: The EndoGastric Solutions EsophyX Z Device with SerosaFuse Fasteners and Accessories is a prescription use only, disposable, single use system consisting of an all mechanical, flexible fastener delivery device with user controls outside the patient's body. The transoral device and tissue fasteners are provided sterile (EO). A separate, commercial endoscope operating independently down the center of the device's flexible shaft lumen provides visualization of the procedure from device insertion through extraction. Two polypropylene fasteners are loaded from a replaceable fastener cartridge containing ten fasteners for each channel. The loaded fasteners are pushed simultaneously from the proximal device end, to the distal end down two separate channels via lumens in a flexible shaft where they are then in position for deployment into the tissue. The operator, controlling the distal end of the device through the mechanical controls captures and positions a fold of tissue at the gastroesophageal junction. The delivery trigger mechanism deploys both fasteners simultaneously at the captured tissue {4}------------------------------------------------ ## 510(k) Summary (Continued): position, creating a permanent surgical fundoplication. Additional fasteners are used as needed to complete the valve restoration. #### Intended Use / Indications for Use [807.92(a)(5)]: The EndoGastric Solutions EsophyX Z Device with SerosaFuse Fasteners and Accessories is indicated for use in transoral tissue approximation, full thickness plication and ligation in the GI tract and is indicated for the treatment of symptomatic chronic qastroesophageal reflux disease in patients who require and respond to pharmacological therapy. It is also indicated to narrow the gastroesophageal junction and reduce hiatal hernia < 2cm in size in patients with symptomatic chronic gastroesophageal reflux disease. #### Summary of the Technological Characteristics compared to the Predicate Device [807.92(a)(6)]: Transoral incisionless fundoplication is the technological principle for both the subject and predicate devices and is based on transoral instrumentation for approximating, ligating and permanently joining esophageal/gastric tissue, restoring the valvular functionality at the gastroesophageal junction and reducing gastroesophageal reflux. Both subject and predicate devices are based on the following technological elements: - . A flexible shaft, fastener delivery device inserted transorally using a separate, appropriately sized endoscope to provide visualization of the entire procedure - Polypropylene, H-shaped fasteners acting as permanent implants to secure tissue - . Use of tissue invagination to correct hiatal hernias up to 2cm - . Mechanical user interface controls on the delivery device which control fastener loading, tissue capture, fastener positioning at the distal device end and fastener deployment through the captured tissue The differences between the modified and predicate device include minor control changes: - . A minor housing change adds more positive helical retractor lock stops - A retractor lock mechanism modification allows the retractor to be pulled back while the lock is engaged. - . An open-side tissue mold control mechanism modification to automatically open the mold when tension is removed on the closed-side. Several non-operator control changes were made: to reduce device part count, reduce cost, increase manufacturability, or as an iterative design refinement. Two patient contacting material changes were made by adding colorant to the same material cleared in the predicate device. Three other non-patient contacting materials were also changed. All were included in system biocompatibility testing. {5}------------------------------------------------ # 510(k) Summary Continued: #### Performance Data on which Substantial Equivalence is Based [807.92(b)(1) and (2)]: Verification and validation testing results provided evidence the device modifications met the design specifications and user needs. Testing included dimensional, mechanical and performance specifications. As part of design validation, cadaver and animal labs were performed verifying fastener deployment in various tissue types. Clinical evaluation as part of design validation was not required for the modifications made to the EsophyX Z to establish safety and effectiveness equivalence. As a result of two different patient contacting materials being incorporated at the distal end of the modified EsophyX Z device, a biocompatibility evaluation was performed. Indicated testing included cytotoxicity, sensitization, and irritation or intracutaneous reactivity testing. Test results demonstrated the modified EsophyX Z meets all relevant biocompatibility testing requirements. #### Conclusions Drawn from Performance Data [807.92(b)(3)] The verification, validation and biocompatibility testing demonstrate the modified EsophyXZ is as safe and effective and performs as well as the predicate device referenced in this submission. The device meets product specifications and user requirements. ### Additional Information [807.92(d)] None. #### Summarv: Based upon the intended use, indications for use, product technical information, performance testing and biocompatibility information provided in this premarket notification, the modified EsophyX Z device has been shown to be substantially equivalent to the predicate EsophyX Z device, when used as intended.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...