GCI · Laryngoscope, Endoscope

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeGCI
Device NameLaryngoscope, Endoscope
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology
3rd-Party ReviewableYes

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (14 of 14)

RecordDevice NameApplicantDecision DateDecision
K021747DEGALL LAPAROSCOPIC GALLBLADDER EXTRACTORSurgicon, Inc.Aug 15, 2002SESE
K003222MODIFICATION TO HERMES OPERATING ROOM CONTROL CENTERComputer Motion, Inc.Nov 3, 2000SESE
K001362KARL STORZ 3D VIDEO SYSTEMKarl Storz Imaging, Inc.Jul 17, 2000SESE
K933515BOOTY ENDOSCOPE WARMERT-Med, Inc.Oct 27, 1993SESE
K930302BIRTCHER SURE CLEAN INSTRUMENT SYSTEMBirtcher Medical Systems, Inc.Oct 27, 1993SESE
K930496GI-1090,1095,1080,1085,1086,1088, ENDO. CLAMPSBirtcher Medical Systems, Inc.Apr 20, 1993SESE
K922123AUTO SUTURE DISPOSABLE ENDOSCOPIC SPECIMEN POUCHUnited States Surgical, A Division of Tyco HealthcFeb 1, 1993SESE
K920139GLEESON CLOT-BUSTERConmedcorpApr 15, 1992SESE
K915762POOLE TIP SUCTION PROBEO.R. Concepts, Inc.Mar 13, 1992SESE
K914120SINGLE USE LAPAROSCOPY ELECTROSURGICAL INSTRUMENTConmedcorpOct 30, 1991SESE
K911829ENDOSTAPLEETHICON, Inc.Aug 28, 1991SESE
K911461SURGITRONEllman Intl. Mfg., Inc.Apr 25, 1991SESE
K905117ENDOSCOPE AND ACCESSORIESNorthgate Technologies, Inc.Apr 25, 1991SESE
K896205MONOSCOPY BRAND, 5 MM LOCKING TROCAR SLEEVEDexide, Inc.Mar 22, 1990SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...