BATTERY POWERED ENDOSCCOPIC LIGHT SOURCE
Device Facts
| Record ID | K960081 |
|---|---|
| Device Name | BATTERY POWERED ENDOSCCOPIC LIGHT SOURCE |
| Applicant | Mitsubishi Cable America, Inc. |
| Product Code | FCQ · Gastroenterology, Urology |
| Decision Date | Mar 12, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
Indications for Use
The Mitsubishi Battery Powered Endoscopic Light Source is intended for use as a light source for diagnostic endoscopes.
Device Story
Lightweight, portable, battery-powered light source for diagnostic endoscopes; utilizes 3V lithium battery and 1.7W halogen bulb; manual on/off switch; connects via friction-fit adaptors to endoscope light cable posts; used by clinicians in diagnostic settings; provides illumination for target visualization; reusable design allows for sterilization and battery replacement.
Clinical Evidence
Bench testing only.
Technological Characteristics
Incandescent light source; 1.7-watt halogen bulb; 3-volt lithium battery; leakproof case; friction-fit connectivity; reusable; sterilizable.
Indications for Use
Indicated for use as a light source for diagnostic endoscopes in patients requiring endoscopic examination.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Predicate Devices
- Xomed-Treace E-Luminator™ II Battery Powered Disposable Endoscope Light Source (K932771)
Related Devices
- K133311 — ENDOLED · Olympus Winter & Ibe GmbH · Jul 30, 2014
- K971455 — CLARUS MODEL 5197 SIGHTLITE · Clarus Medical Systems, Inc. · May 20, 1997
- K091829 — PLS PORTABLE LIGHT SOURCE · Optim, Inc. · Jul 28, 2009
- K962595 — KARL STORZ XENON 300 LIGHT SOURCE FOR NON-FLASH APPLICATIONS · KARL STORZ Endoscopy-America, Inc. · Sep 4, 1996
- K023468 — ENDOSCOPIC LIGHT SOURCE XL180/L3 · World of Medicine Lemke GmbH · Jan 14, 2003