The device is a control unit intended to drive contra angles and other attachments that are used with appropriate burs and drills for drilling, reaming, decorticating, and smoothing of bone and other bone related tissue in a variety of dental, oral surgical and other small surgical procedures.
Device Story
Surgic IV Dental Implant Unit is a control unit designed to power dental handpieces, contra angles, and attachments. It utilizes an electric micromotor to drive burs and drills for bone surgery. The system includes a roller pump for delivering saline or sterile water irrigation to the surgical site via a disposable, ETO-sterilized irrigation tube set. Operated by dental or oral surgeons in clinical settings, the device provides mechanical power and irrigation control to facilitate bone preparation. The healthcare provider uses the unit to perform precise bone procedures; the irrigation system helps maintain tissue temperature and clear debris. The device is not for use in environments with flammable anesthetics.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Control unit with electric micromotor and roller pump irrigation system. Micromotor and cord are autoclavable. Irrigation tube set is ETO sterilized, pyrogen-free. Operates as a dental handpiece accessory. Class I device.
Indications for Use
Indicated for dental, oral, and small surgical procedures requiring drilling, reaming, decorticating, and smoothing of bone and bone-related tissue. Contraindicated for use in the presence of flammable anesthetics.
Regulatory Classification
Identification
A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.
Related Devices
K972924 — SURGIC II IMPLANT CONTROL UNIT · Nsk Nakanishi, Inc. · Oct 30, 1997
K984244 — ORL-E-92 SURGICAL DRILL SYSTEM · Bien Air USA, Inc. · Feb 23, 1999
K171155 — Surgical Angle Handpiece, Surgical Straight Handpiece · Nakanishi, Inc. · Nov 21, 2017
K060287 — DRILLTECH, ISM, IMPLANTUNIT, ZIMMER SURGICAL MOTOR SYSTEM · W&H Dentalwerk Buermoos GmbH · May 3, 2006
Submission Summary (Full Text)
{0}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle with three human profiles incorporated into its design. The eagle's head and wings are stylized, and the profiles are facing to the right.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Mr. Hiroji Sekiguchi Marketing Director Nakanishi, Incorporated 700 Shimohinata Kanuma-Shi. Touchigi-Ken, JAPAN
Re: K020327
Trade/Device Name: Surgic IV Dental Implant Unit Regulation Number: 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EBW Dated: January 29, 2002 Received: January 31, 2002
Dear Mr. Sekiguchi:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements
{1}------------------------------------------------
### Page 2 - Mr. Sekiguchi
of the Act or any Federal statutes and regulations administered by other Federal agencies. or the Act of all - such all the Act's requirements, including, but not limited to: registration r ou intist compry with a 807); labeling (21 CFR Part 801); good manufacturing practice and ifsing (21 et read on the quality systems (QS) regulation (21 CFR Part 820); and if requirents as between product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 110(k) premarket notification. The FDA finding of substantial equivalence of your device to s rotts) premiered predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and alle Act may of overained its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours
Timothy Ulatowski
Timo Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health
{2}------------------------------------------------
# 020327
### Indications For Use Statement
510(k) Number (if known):
Device Name:
Surgic IV Dental Implant Unit
Indications For Use:
The device is a control unit intended to drive contra angles and other attachments that are used with appropriate burs and drills for drilling, reaming, decorticating, and smoothing of bone and other bone related tissue in a variety of dental, oral surgical and other small surgical procedures.
### Remarks:
The control unit is equipped with a roller pump to deliver saline solution or sterile water as irrigant to the handpiece. The electric micromotor and its cord are autoclavable. The irrigation tube set used between the irrigation nozzle at the handpiece and the saline solution bottle via roller pump is supplied as an accessory item in the control unit package. It is ETO sterilized for 10 sterility, pyrogen-free.
The control unit has risk of explosion if used in the presence of flammable anesthetics.
## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Susan Runne
| (Division Sign-Off) | |
|---------------------------------------------------------------------|---------|
| Division of Dental, Infection Control, and General Hospital Devices | |
| 510(k) Number | K020327 |
Prescription Use (Per 21 CFR 801.109) OR
Over-The-Counter Use _
(Optional Format 1-2-96
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.