ARAGON WIRING SYSTEM WIRE CARTRIDGE, MODELS I0007 WIRE CARTRIDGE, 22 GAUGE, I0008 WIRE CARTRIDGE, 24 GAUGE, I0009 WIRE E
K022821 · Ideatrics, Inc. · DZK · Nov 15, 2002 · Dental
Device Facts
Record ID
K022821
Device Name
ARAGON WIRING SYSTEM WIRE CARTRIDGE, MODELS I0007 WIRE CARTRIDGE, 22 GAUGE, I0008 WIRE CARTRIDGE, 24 GAUGE, I0009 WIRE E
Applicant
Ideatrics, Inc.
Product Code
DZK · Dental
Decision Date
Nov 15, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.4880
Device Class
Class 2
Attributes
Therapeutic, Pediatric
Indications for Use
This device is used in surgery for the application of wires to the jaws of adults and children. The device can be used to directly wire bony segments together, or for the application of arch bars to the teeth for stabilization of bony fragments or wiring the teeth together (maxillomandibular fixation).
Device Story
Aragon Wiring System consists of 22, 24, and 26 gauge annealed 316LVM stainless steel wire; supplied in 5 ft. coils within a thermoplastic cartridge. Cartridge mounts directly onto forceps for surgical application. Used by surgeons in clinical settings for mandibular fracture stabilization; wire applied to jaws to secure bony segments or attach arch bars. System replaces traditional long-length wire spools (75-675 ft.) kept on instrument trays with a single-use, cartridge-based delivery method. Facilitates efficient wire handling during maxillomandibular fixation procedures.
Clinical Evidence
No clinical data; bench testing only.
Technological Characteristics
Material: 316LVM stainless steel wire. Gauges: 22, 24, 26. Form factor: 5 ft. coils in thermoplastic cartridge. Delivery: Cartridge mounts to forceps. Sterilization: Not specified.
Indications for Use
Indicated for stabilization of mandibular fractures in adults and children requiring surgical wiring of bony segments or arch bars for maxillomandibular fixation.
Regulatory Classification
Identification
An intraosseous fixation screw or wire is a metal device intended to be inserted into fractured jaw bone segments to prevent their movement.
Predicate Devices
Intraosseous Fixation Wire by Synthes
Intraosseous Fixation Wire by Biomet-Kirschner
Intraosseous Fixation Wire by Stryker Instruments
Intraosseous Fixation Wire by Dupuy International Ltd.
Intraosseous Fixation Wire by Zimmer, Inc.
Intraosseous Fixation Wire by Mathys Medical Ltd.
Related Devices
K092530 — SPRYTIE, MODELS ST001, ST002 AND ST003 · Russell B. Walther · Apr 2, 2010
K960385 — STERILE KIRSCHNER WIRES AND STEINMANN PINS · Depuy, Inc. · Mar 27, 1996
Submission Summary (Full Text)
{0}------------------------------------------------
K022821
SECTION C - 510(K) SUMMARY
NOV 1 5 2002
Ideatrics, Inc. 7341 South Meadow Court Boulder, Colorado 80301 phone: 303-527-0515 FAX: 303-449-7805 contact: James W. Heller, President
Submitted: August 19, 2002
Trade Name: Aragon Wiring System Wire Cartridge (models I0007, I0008, I0009, I0010, I0011 and I0012)
Common Name: Stainless Steel Wire for Mandibular Fixation
- Classification: Class II, Dental classification panel, product code Intraosseous Fixation Wire, CFR section DZK , 872.4880. Intraosseous Fixation Screw or Wire
- Predicate Devices: Intraosseous Fixation Wire by Synthes, Biomet-Kirschner, Stryker Instruments, Dupuy International Ltd., Zimmer, Inc. and Mathys Medical Ltd.
Device description: 22, 24 and 26 gauge annealed 316LVM stainless steel wire in 5 ft. coils packaged in a thermoplastic cartridge that mounts on forceps
Intended Use: Stabilization of mandibular fractures
- Technical differences from Predicate devices: Wire is identical to predicate devices. It is packaged in a 5 ft. length in a single use cartridge that mounts on forceps. In predicate devices the wire is packaged in a 75-675 ft. length on a reusable spool that is kept on the surgical instrument tray.
Conclusion: The technical differences between this product and the predicate devices do not adversely affect safety or efficacy.
{1}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
## NOV 1 5 2002
Mr. James W. Heller President Ideatrics, Incorporated 7341 South Meadow Court Boulder, Colorado 80301
Re: K022821
Trade/Device Name: Aragon Wiring System Regulation Number: 21 CFR 872.4880 Regulation Name: Intraosseous Fixation Screw or Wire Regulatory Class: II Product Code: DZK Dated: August 19, 2002 Received: August 26, 2002
Dear Mr. Heller:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition. FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
Page 2 - Mr. Heller
1. 1.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus. permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours
Timothy A Ulatowski Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Page One of One
510(k) Number (if known): K022821
Device Name:_ Aragon Wiring System
Indications For Use:
This device is used in surgery for the application of wires to the jaws of adults and children. The device can be used to directly wire bony segments together, or for the application of arch bars to the teeth for stabilization of bony fragments or wiring the teeth together (maxillomandibular fixation).
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109) OR
Over-The-Counter Use
(Optional Format 1-2-96)
(Division Sign-Off) Division of Anesthesiology, General Hospital, Infection Control, Dental Devices
510(k) Number ..
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.