MPD · Auxiliary Power Supply (Ac Or Dc) For Low-Energy Dc-Defibrillator

Cardiovascular · 21 CFR 870.5300 · Class 2

Overview

Product CodeMPD
Device NameAuxiliary Power Supply (Ac Or Dc) For Low-Energy Dc-Defibrillator
Regulation21 CFR 870.5300
Device ClassClass 2
Review PanelCardiovascular
Life-SustainingYes

Identification

Low-energy DC-defibrillator: A device that delivers into a 50 ohm test load an electrical shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart or to terminate other cardiac arrhythmias. This generic type of device includes low energy defibrillators with a maximum electrical output of less than 360 joules of energy that are used in pediatric defibrillation or in cardiac surgery. The device may either synchronize the shock with the proper phase of the electrocardiogram or may operate asynchronously. The device delivers the electrical shock through paddles placed either directly across the heart or on the surface of the body. High-energy DC-defibrillator: A device that delivers into a 50 ohm test load an electrical shock of greater than 360 joules of energy used for defibrillating the atria or ventricles of the heart or to terminate other cardiac arrhythmias. The device may either synchronize the shock with the proper phase of the electrocardiogram or may operate asynchronously. The device delivers the electrical shock through paddles placed either directly across the heart or on the surface of the body.

Classification Rationale

Low-energy DC-defibrillator: Class II (performance standards). High-energy DC-defibrillator: Class III (premarket approval).

Recent Cleared Devices (3 of 3)

RecordDevice NameApplicantDecision DateDecision
K253099LIFEPAK 15 AC Power Adapter (41577-000333)Physio-Control, Inc.Oct 14, 2025SESE
K240162LIFEPAK® 35 AC Power Adapter (41335-000001)Stryker Physio-ControlApr 19, 2024SESE
K062331HIGHPAK-12Ad Elektronik GmbHJul 10, 2007SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...