K962726 · C.R. Bard, Inc. · DTP · Oct 30, 1996 · Cardiovascular
Device Facts
Record ID
K962726
Device Name
BARD QUANTUM CVR
Applicant
C.R. Bard, Inc.
Product Code
DTP · Cardiovascular
Decision Date
Oct 30, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.4230
Device Class
Class 2
Indications for Use
The Bard® Quantum™ CVR is designed to function in an extracorporeal circuit. The filtered cardiotomy/reservoir receives dynamic blood from: (1) venous return (2) intracardiac suction (3) ventricular vent devices (4) arterial-venous shunts. It defoams, filters and stores this blood before returning it to the circuit.
Device Story
The Bard® Quantum™ CVR is a cardiotomy and venous reservoir used in extracorporeal circuits during cardiopulmonary bypass. It receives blood from venous return, intracardiac suction, ventricular vents, and arterial-venous shunts. The device functions by defoaming, filtering, and storing this blood before returning it to the bypass circuit. It is intended for intraoperative use by perfusionists or surgeons in a clinical setting. The device benefits patients by managing blood volume and ensuring blood quality (defiltration/defoaming) during bypass procedures.
Clinical Evidence
Bench testing only. Performance and integrity characteristics were compared against predicate devices (Cobe HVRF and Bard H-3700). Testing evaluated cell damage, defoaming ability, and filtration efficiency. Biocompatibility testing was conducted in accordance with ISO 10993 standards.
Technological Characteristics
Cardiotomy and venous reservoir with integral defoamer and filter. Materials are consistent with predicate devices. Biocompatibility compliant with ISO 10993.
Indications for Use
Indicated for use in extracorporeal systems during cardiopulmonary bypass to receive, defoam, filter, and store blood from venous return, intracardiac suction, ventricular vents, and arterial-venous shunts.
Regulatory Classification
Identification
A cardiopulmonary bypass defoamer is a device used in conjunction with an oxygenator during cardiopulmonary bypass surgery to remove gas bubbles from the blood.
Special Controls
*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance for Extracorporeal Blood Circuit Defoamer 510(k) Submissions.”
Predicate Devices
Bard® William Harvey® Cardiotomy Reservoir with MICRO Filter (H-3700) (K902856)
Cobe HVRF®-3700 Open Venous Reservoir with Integral Cardiotomy Filter
Related Devices
K990514 — MODIFICATION OF BARD QUANTUM CVR, MODEL H-6770VR · C.R. Bard, Inc. · Mar 9, 1999
K090534 — VENOUS HARDSHELL CARDIOTOMY RESERVIORS · Maquet Cardiopulmonary, AG · Dec 23, 2009
K971669 — COBE HVR 4000 FILTERED AND NONFILTERED HARDSHELL VENOUS RESERVOIR · Cobe Cardiovascular, Inc. · Jul 23, 1997
Submission Summary (Full Text)
{0}
K960726
OCT 30 1996
Bard Vascular Systems Division
C.R. Bard, Inc.
25 Computer Drive
Haverhill, MA 01832
508-373-1000
BARD
# 510(k) SUMMARY FOR THE BARD® QUANTUM™ CVR
This 510(k) Summary of Safety and Effectiveness is being submitted in accordance with the requirements of SMDA 1990.
## A. Submitter’s Information
Name: C.R. Bard, Inc., Bard Vascular Systems Division
Address: 25 Computer Drive, Haverhill, MA 01832
Phone: (508) 373-1000 extension 3371
Fax: (508) 374-6200
Contact Person: Douglas E. Ferguson, Regulatory Affairs Specialist
Date of Preparation: July 12, 1996
## B. Device Name:
Trade Name: Bard® Quantum™ CVR
Common/Usual Name: Cardiotomy and Venous Reservoir with Defoamer
Classification Name: Cardiopulmonary Bypass Blood Reservoir with Cardiopulmonary Bypass Defoamer
## C. Predicate Device Name(s):
1) Bard® William Harvey® Cardiotomy Reservoir with MICRO Filter (H-3700) (510(k) #K902856)
2) Cobe HVRF®-3700 Open Venous Reservoir with Integral Cardiotomy Filter
## D. Device Description/Indications for Use:
The Bard® Quantum™ CVR is designed to function in an extracorporeal circuit. The filtered cardiotomy/reservoir receives dynamic blood from:
(1) venous return
(2) intracardiac suction
(3) ventricular vent devices
(4) arterial-venous shunts
It defoams, filters and stores this blood before returning it to the circuit.
Bard® Quantum™ CVR 510(k) Submission
{1}
Bard® Quantum™ CVR 510(k) Submission
52
# E. Technological Characteristics Summary
The "510(k) Substantial Equivalence Decision-Making Process (Detailed)" decision tree (FDA 92-415, Premarket Notification 510(k): Regulatory Requirements for Medical Devices, Page 51) was utilized to make a determination of substantial equivalence as follows:
1. Does New Device Have Same Indication Statements?
Yes. The Bard® Quantum™ CVR (Bard H6770VR) has the same indications as the Cobe HVRF although the Bard H6770VR includes additional detail. The Bard H-3700 and the Bard H6770VR have the same indications for use intraoperatively; however the Bard H6770VR will not be indicated for post-operative use as the Bard H-3700 is. Although the wording in the Indications for Use for all of these devices is not identical, all of these devices are indicated for use in extracorporeal systems during cardiopulmonary bypass.
2. Does New Device Have Same Technological Characteristics, e.g., Design, Materials, etc.?
Yes. The Bard H6770VR has the same technological characteristics and the same materials as at least one of the predicate devices or the difference is insignificant.
3. Are the Descriptive Characteristics Precise Enough to Ensure Equivalence?
No. Although the materials and technological characteristics are the same, bench testing is necessary to ensure equivalence because of (1) differences between vendors and manufacturing techniques and (2) the fact that neither of the predicate devices individually include all the same materials and technological characteristics as those of the proposed device.
4. Are Performance Data Available to Assess Equivalence?
Yes. The Bard H6770VR, the Cobe HVRF, and the Bard H-3700 were compared for performance and integrity characteristics. In addition, the Bard H6770VR was subjected to biocompatibility testing.
{2}
# 5. Performance Data Demonstrate Equivalence?
Yes. The proposed device was found to be equivalent to or better than the predicated devices or differences were clinically insignificant in terms of cell damage, defoaming ability, and filtration efficiency.
The Bard H6770VR passed all tests of biocompatibility required by the International Standard ISO 10993.
## SUBSTANTIALLY EQUIVALENT DETERMINATION:
The Bard H6770VR is substantially equivalent to the predicate devices, the Cobe HVRF and the Bard H-3700.
Bard® Quantum™ CVR 510(k) Submission
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.