RANDOX ALDOLASE CALIBRATION SERUM
Device Facts
| Record ID | K142181 |
|---|---|
| Device Name | RANDOX ALDOLASE CALIBRATION SERUM |
| Applicant | Randox Laboratories Limited |
| Product Code | JIT · Clinical Chemistry |
| Decision Date | Sep 18, 2014 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1150 |
| Device Class | Class 2 |
Indications for Use
The Aldolase Calibration Serum is intended for in vitro diagnostic use in the calibration of Aldolase on the Randox RX Daytona and Beckman Coulter AU640 systems. This device is for prescription use only.
Device Story
Randox Aldolase Calibration Serum is a lyophilized human serum-based product used to calibrate Aldolase assays on specific clinical chemistry analyzers (Randox RX Daytona and Beckman Coulter AU640). The product is supplied as a kit (3x1ml vials) and requires reconstitution with distilled water. It is intended for professional use in clinical laboratory settings. By providing a standardized reference material with assigned Aldolase values, the device enables the calibration of automated clinical chemistry systems, ensuring accurate measurement of patient Aldolase levels. This supports clinicians in diagnosing and monitoring conditions associated with Aldolase activity. The device is handled by laboratory technicians; it is derived from human serum tested for HIV, HBsAg, and HCV, though it must be treated as potentially infectious.
Clinical Evidence
Bench testing only. Stability studies (open-vial and real-time) confirmed a 5-day reconstituted stability and 2-year shelf life with recovery within ±5% of acceptance criteria. Value assignment was validated via nested testing against master lots on clinical chemistry analyzers, achieving precision (CV) of 1.8% to 2.2%, meeting the ≤3% acceptance criterion.
Technological Characteristics
Lyophilized human serum matrix; contains Aldolase derived from rabbit muscle (Sigma A2714). Designed for use on Randox RX Daytona and Beckman Coulter AU640 systems. Storage at +2°C to +8°C. No electronic or software components.
Indications for Use
Indicated for in vitro diagnostic use as a calibrator for Aldolase assays on Randox RX Daytona and Beckman Coulter AU640 systems. Intended for prescription use.
Regulatory Classification
Identification
A calibrator is a device intended for medical purposes for use in a test system to establish points of reference that are used in the determination of values in the measurement of substances in human specimens. (See also § 862.2 in this part.)
Special Controls
*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.
Related Devices
- K053153 — RANDOX CALIBRATION SERUM · Randox Laboratories, Ltd. · Jan 13, 2006
- K141388 — SYSTEM CALIBRATER · Beckman Coulter Ireland, Inc. · Jul 11, 2014
- K131776 — ALDOLASE CONTROLS LEVEL 2, AND ALDOLASE CONTROL LEVEL 3 · Randox Laboratories, Ltd. · Jul 18, 2013