EASYMED PERIPHERAL NERVE STIMULATOR-SUNSTIN

K121743 · Sunmed, LLC · BXN · Mar 28, 2013 · Anesthesiology

Device Facts

Record IDK121743
Device NameEASYMED PERIPHERAL NERVE STIMULATOR-SUNSTIN
ApplicantSunmed, LLC
Product CodeBXN · Anesthesiology
Decision DateMar 28, 2013
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 868.2775
Device ClassClass 2

Indications for Use

EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator is a battery-powered device intended for monitoring the magnitude of neuromuscular blocks in general anesthesia, by delivering an electrical stimuls near a peripheral motor nerve.

Device Story

Battery-powered peripheral nerve stimulator; delivers low electrical direct current (DC) stimulation near peripheral motor nerves to assess anesthetic nerve block levels. Features variable current control (0-70 mA into 2K ohm load); output stimulus pulse indicator; modes include Train-of-Four, Twitch, and 100Hz Tetanus. Used in clinical settings (e.g., OR) by anesthesia providers to ensure supramaximal stimulation. Output allows clinicians to monitor pharmacological effects of anesthetic drugs/gases, aiding clinical decision-making regarding neuromuscular blockade management.

Clinical Evidence

Bench testing only. Testing included electromagnetic compatibility (EN 60601-1-2: 2007), radiated emissions, ESD, radiated immunity, and power-frequency magnetic field immunity. Physical performance testing verified pulse amplitude, pulse width, pulse frequency, and low battery indicator functionality.

Technological Characteristics

Battery-powered electrical stimulator; provides 0-70 mA DC output into 2K ohm load. Modes: Train-of-Four, Twitch, 100Hz Tetanus. Complies with EN 60601-1-2: 2007 for EMC and ISO 14971:2007 for risk management. Manual control via dial.

Indications for Use

Indicated for monitoring neuromuscular block magnitude in patients undergoing general anesthesia by delivering electrical stimulation near peripheral motor nerves.

Regulatory Classification

Identification

An electrical peripheral nerve stimulator (neuromuscular blockade monitor) is a device used to apply an electrical current to a patient to test the level of pharmacological effect of anesthetic drugs and gases.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ i21743 # MAR 28 2013 #### EasyMed Instruments Co., LTD. 5/F - 6/F, block A, Gupo Gongmao Building, Fengxin Road, Fengxiang Industrial District, Daliang, Shunde, Foshan, CHINA 528300 Phone: +86 757 2809 1300 ## 510(k) SUMMARY 21 CFR 807.92(c) #### SUBMITTER INFORMATION 510k Owner: Company Address: EasyMed Instruments Co., LTD. +86 757 2809 1300 Wu Tingjie/ Owner April 17, 2012 March 27, 2013 5/F ~ 6/F, block A, Gupo Gongmao Building, Fengxin Road, Fengxiang Industrial District, Daliang, Shunde, Foshan, CHINA 528300 Company Phone: Contact Person: Date Summary Prepared: Date of Updated Summary: #### DEVICE INFORMATION Trade/Proprietary Name: Common/Usual Names: Classification Name: Product Code: EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator Peripheral Nerve Stimulator Battery-Powered Nerve Stimulator Electrical Peripheral Nerve Stimulator 21 CFR 868.2775 BXN EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator 510(k) Premarket Notification {1}------------------------------------------------ #### IDENTIFICATION OF PREDICATE DEVICE | Company | Device | 510k No. | |-----------------------|----------|----------| | Life-Tech Intl., Inc. | MiniStim | K913184 | #### DEVICE DESCRIPTION The EasyMed Peripheral Nerve Stimulator devices are battery powered peripheral nerve stimulators which provide low electrical direct current (DC) stimulation in order to determine the level of anesthetic nerve block. The Stimulus Amplitude control dial provides variable current control (0 to 70 mA into a 2K ohm load). The Output Stimulus Pulse Indicator flashes each time current passes through the patient. Functions include: Train-of-Four, Twitch, and 100Hz Tetanus. The device offers sufficient output to ensure supramaximal stimulation: from 0 to 70 mA. All finished products are tested and must meet all required release specifications before distribution. Testing includes physical testing (e.g. Pulse Amplitude, Pulse Width, Pulse Frequency and Low Battery Voltage Indicator) and visual examination. #### INTENDED USE EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator is a battery-powered device intended for monitoring the magnitude of neuromuscular blocks in general anesthesia, by delivering an electrical stimuls near a peripheral motor nerve. #### TECHNOLOGICAL CHARACTERISTICS The technical characteristics of the EasyMed Peripheral Nerve Stimulators are similar to those of the predicate device in design, energy source, intended use and function. Like the predicate device, the EasyMed Peripheral Nerve Stimulators are devices used to apply an electric current to a patient to test the level of pharmacological effect of anesthetic drugs and gases. A comparative summary of the EasyMed device to the predicate device is provided in Section 12.0, Table 1. EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator 510(k) Premarket Notification {2}------------------------------------------------ #### PERFORMANCE DATA (e.g. non-clinical testing) The EasyMed Peripheral Nerve Stimulator underwent the tests noted in the below table and results are indicated as well. The full test report can be found in Section 21.0 Appendix -Appendix VIII. | Test | Test Requirement | Test Method | Result | |-----------------------------------------------------------------------------------|--------------------|------------------------------------------------|--------| | Electromagnetic<br>Interference -<br>Radiated Emission<br>(30 MHz to 1 GHz) | EN 60601-1-2: 2007 | EN 55011: 2009<br>+ A1: 2010 | Pass | | Electromagnetic<br>Susceptibility - ESD | EN 60601-1-2: 2007 | EN 61000-4-2: 2009 | Pass | | Electromagnetic<br>Susceptibility -<br>Radiated Immunity (90<br>MHz to 2.5 GHz) | EN 60601-1-2: 2007 | EN 61000-4-3: 2006<br>+ A1: 2008<br>+ A2: 2010 | Pass | | Electromagnetic<br>Susceptibility -<br>Power-frequency magnetic<br>field immunity | EN 60601-1-2: 2007 | EN 61000-4-8:1993<br>+ A1: 2001 | Pass | ### BASIS OF SUBSTANTIAL EQUIVALENCE/CONCLUSION EasyMed Peripheral Nerve Stimulators have been tested and found to perform as intended. EasyMed Peripheral Nerve Stimulators have been compared to legally cleared predicate device and found to be substantially equivalent. Substantial equivalence testing results can be found in section 12.0. The EasyMed Peripheral Nerve Stimulator and Stimulator Plus models have the same functions with the following exceptions: the Peripheral Nerve Stimulator functions do not include double burst and 2 tetanus options (50 Hz and 100 Hz). #### STANDARDS ISO 14971:2007 Medical Devices - Application of Risk Management to Medical . Devices . EN 60601-1-2: 2007 (Second edition, 2001), Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance- Collateral Standard: Electromagnetic Compatibility - Requirements and Tests EasyMed Instruments Co., LTD. Peripheral Nerve Stimulator 510(k) Premarket Notification {3}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three stripes forming its body and wing. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. #### March 28, 2013 SunMed Limited Liability Company C/O Mr. Wu Tingjie EasyMed Instruments Company, Limited 5/F - 6/F, Block A, Gupo Gongmao Building Fengxin Road, Fengxiang Industrial District Daliang, Shunde, Foshan China 528300 Re: K121743 Trade/Device Name: Peripheral Nerve Stimulator Regulation Number: 21 CFR 868.2775 Regulation Name: Electrical Peripheral Nerve Stimulator Regulatory Class: II Product Code: BXN Dated: February 22, 2013 Received: February 25, 2013 Dear Mr. Tingjie: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 {4}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (2) CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely vours. Image /page/4/Picture/7 description: The image shows the words Kwame Ulmer-S in a stylized font. The letters are black and bolded, and the words are stacked on top of each other. The letters are slightly distorted, and the image has a grainy texture. There is also a logo to the right of the words. for Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ #### Indications for Use 510(k) Number (if known): Device Name: Peripheral Nerve Stimulator K121743 Indications for Use: The EasyMed InstrumentsCo., LTD. Peripheral Nerve Stimulator is a battery -powered device intended for monitoring the magnitude of neuromuscular blocks in general anesthesia; by delivering an electrical stimulus near a peripheral motor nerve. Prescription Use ਮ (Part 21 CFR 801 Subpart D) + AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED Concurrence of CDRH, Office of Device Evaluation (ODE) Lester W. Schultheis Jr 2013.03.27 12:42:42:44:204'00' (Division Sign-Off) (Division Sign-Off) Division of Anesthesiology, General Hosphal Division of Anesthesiology, General Devices Division of Allestheolorology. Infection Control, Dental Devices Kreizer 510(k) Number:_
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...