K Number
K962583

Validate with FDA (Live)

Date Cleared
1996-12-18

(170 days)

Product Code
Regulation Number
890.3800
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Action Cat Scooter with DS60 Controller is intended to be used to provide mobility to persons restricted to a seated position.

Device Description

As indicated above, the Action Cat Scooter with DS60 Controller is intended for use to provide mobility to persons restricted to a seated position. The scooter has a total weight of 160 pounds (including batteries), and its overall width, track, and wheelbase are 24", 34", and 46", respectively. All upholstery on the device is flame rated to FMVSS302 and CMVSS302. The maximum grade is 9 degrees with a 300 pound load, and the leakage current is less than 100 amperes. The maximum load is 300 pounds, and the maximum speed for the scooter is 5 (±1) mph. The scooter does not have separate "slow," "normal," and "fast" speed control modes; instead, the speed of the vehicle simply is determined on a continuous range by how far the user pushes the speed control bar/tiller.

The braking system for the scooter is electromechanical. Activation of the throttle speed control (either forward or reverse), causes the engagement of an electromagnet which overcomes spring pressure and releases the brake. Releasing the throttle causes the motor control board to induce dynamic braking and reduce speed. Once motor revolution reaches zero, the electromagnet will release, allowing the spring pressure to apply the brake. As an additional feature, the scooter will not operate if the brake is disconnected. The brake is designed to hold a 400 pound load on a 15 degree incline. On level ground with dry conditions and a 300 pound load, braking time from a top speed of 6 mph to zero is 1 second and requires a distance of 5 feet.

The Action Cat Scooter with DS60 Controller uses two 12 volt gel cell batteries. The scooter's range on a standard charge varies according to temperature and battery condition, but the average range is approximately 25 miles. The front approach angle for the Action Cat Scooter with DS60 Controller is 71 degrees, and the rear departure angle is 13 degrees. At the scooter's center, the ground clearance from the chassis is 3.0". Likewise, the maximum curb clearance is 3.0". The breakover angle is 10 degrees, and the minimum radius at which the Action Cat Scooter with DS60 Controller will not tip (at maximum speed) is 6 feet.

The controller for the scooter is a Model DS60 system for DC motor control applications. The DS60 Controller is designed to operate with a nominal 24 volt battery input and to yield a maximum output current of 60 amperes. It also is designed to control a single conventional permanent magnet DC motor with a solenoid-controlled motor brake. The controller incorporates motor load compensation which provides precise motor control over a wide range of driving conditions, thereby maintaining the selected speed of the scooter at a constant level, regardless of the surface type or grade on which the vehicle is driven. This feature ensures less roll-back when stopping the Action Cat Scooter on a slope. The correct level of load compensation depends on the type of motor used and the length of the wiring, and is easily set using the separate handheld DS Programmer.

The programmable features of the DS60 Controller include forward/reverse acceleration, forward/reverse deceleration, motor resistance, etc. It should be noted, however, that although the DS60 Controller for the modified Cat Scooter is programmable, all parameters for the controller will be set only by the factory (i.e., Invacare) prior to sale, and no modifications will be made by either the retailer or the user of the scooter. The DS100 Programmer will not be available for purchase.

The DS60 Controller is a single printed circuit board fixed to an aluminum base. A plastic vacuum-molded case protects the electronics of the DS60 Controller. The DS60 Controller also is protected against accidental reverse battery connection.

Several accessories are available through Invacare for the modified Action Cat Scooter. These options are: a basket, antitipper components, a flat-free insert, an extended throttle lever, a safety flag, a crutch/cane carrier, and a spare key set. The Action Cat Scooter with DS60 Controller also is available in a compact style which measures 43½ inches in length (versus 50" for the regular size scooter).

AI/ML Overview

This 510(k) summary describes a powered scooter, the "Action Cat Scooter with DS60 Controller," and compares it to a predicate device, the "Invacare Cat Scooter (K941966)." The document focuses on demonstrating substantial equivalence rather than presenting a performance study with specific acceptance criteria in the way a medical device utilizing AI/ML might.

Here's an analysis based on your request, with the understanding that the provided text is for a mechanical device and not an AI/ML powered medical device, thus many of your requested fields are not applicable:


Analysis of Acceptance Criteria and Study for the Invacare Action Cat Scooter with DS60 Controller

1. Table of Acceptance Criteria and Reported Device Performance

For this mechanical device, "acceptance criteria" are largely defined by regulatory standards met and direct comparison to a predicate device's established performance and specifications. The document highlights the device meeting an ISO draft standard for electromagnetic compatibility and various performance tests.

Acceptance Criteria / SpecificationReported Device Performance (Action Cat Scooter with DS60 Controller)
Intended UseProvides mobility to persons restricted to a seated position
Total Weight (including batteries)160 pounds
Overall Width24"
Track34"
Wheelbase46"
Upholstery Flame RatingFMVSS302 and CMVSS302 compliant
Maximum Grade (300 lb load)9 degrees
Leakage CurrentLess than 100 amperes
Maximum Load300 pounds (increased from 250 lbs for predicate)
Maximum Speed5 (±1) mph
Braking SystemElectromechanical, dynamic braking with spring-applied brake
Brake Hold (on incline)Holds a 400 pound load on a 15 degree incline
Braking Time (6mph to 0, 300 lb, dry level)1 second
Braking Distance (6mph to 0, 300 lb, dry level)5 feet
BatteriesTwo 12 volt gel cell batteries
Average Range (standard charge)Approximately 25 miles (varies by temp/battery)
Front Approach Angle71 degrees
Rear Departure Angle13 degrees
Ground Clearance (center chassis)3.0"
Maximum Curb Clearance3.0"
Breakover Angle10 degrees
Minimum Non-Tipping Radius (max speed)6 feet
Controller Output CurrentMaximum 60 amperes
EMC ComplianceMet required performance criteria per ISO EMC Draft Standard 7176-14
FunctionalityFunctioned as intended

2. Sample Size Used for the Test Set and Data Provenance

  • Sample Size: Not explicitly stated as a numerical sample size of devices tested. The language indicates "the Action Cat Scooter with DS60 Controller was tested," implying at least one unit was subjected to the described tests.
  • Data Provenance: The tests were conducted internally by Invacare Corporation ("Invacare... was tested," "tests performed voluntarily by Invacare"). There is no mention of country of origin for the data or if it was retrospective or prospective, as this is a new device being qualified against standards for market entry.

3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

  • Experts/Ground Truth: Not applicable in the context of this mechanical device. The "ground truth" here is compliance with engineering specifications, safety standards, and functional performance, which would be assessed through objective measurements and standard test protocols, not expert consensus on diagnostic interpretations.

4. Adjudication Method for the Test Set

  • Adjudication Method: Not applicable. Performance is measured against physical specifications and regulatory standards, not subjective interpretations requiring adjudication.

5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

  • MRMC Study: Not applicable. This is a mechanical mobility device, not a diagnostic medical device involving human interpretation of data (e.g., medical images) with or without AI assistance.

6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

  • Standalone Performance: Not applicable. While the device contains a "digital controller," it is not an AI/ML algorithm acting in a standalone diagnostic or decision-making capacity. It's a control system for a mechanical device, inherently designed for human operation (human-in-the-loop).

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

  • Type of Ground Truth: The "ground truth" for this device's performance is adherence to established engineering specifications, safety standards (e.g., flame rating, leakage current), and functional requirements (e.g., maximum speed, braking distance, grade capability). These are objectively measurable physical properties and performance metrics. Substantial equivalence is also a key "ground truth" metric, relying on direct comparison of specifications to a predicate device.

8. The sample size for the training set

  • Training Set Sample Size: Not applicable. This device does not use an AI/ML algorithm that requires a "training set" in the conventional sense. The "training" for the controller involves factory programming of parameters, not machine learning from a dataset.

9. How the ground truth for the training set was established

  • Training Set Ground Truth: Not applicable. As there is no AI/ML training set, there is no ground truth established for one. The programmable features of the DS60 controller are "set only by the factory (i.e., Invacare) prior to sale," based on engineering design and performance optimization, rather than a data-driven ground truth.

Summary of the Study:

The "study" described in the 510(k) summary is primarily focused on demonstrating substantial equivalence to a predicate device (Invacare Cat Scooter K941966) and compliance with regulatory standards for powered wheelchairs and motorized scooters.

  • The key test explicitly mentioned is compliance with ISO EMC Draft Standard 7176-14 (Titled "Draft ISO EMC Group Proposal: Electromagnetic Compatibiliity Addition" And Dated April 3, 1995). The device "met the required performance criteria and functioned as intended" in all instances of this test.
  • Additionally, the document states the device "passed a number of performance tests performed voluntarily by Invacare." While specifics of these voluntary tests are not detailed, they would likely cover the various specifications listed (e.g., maximum speed, braking, grade capability, anti-tipping, range, etc.).
  • The primary method of demonstrating acceptance is through direct comparison of specifications and features to the predicate device, highlighting that "The predicate motorized three-wheeled vehicle is nearly identical to the Action Cat Scooter with DS60 Controller and has the same intended use." The differences (digital vs. analog controller, increased weight limit, onboard charger, compact model, adjustable seat) are deemed "minor and raise no new questions of safety and effectiveness."

In essence, the "study" is a combination of direct specification comparison and compliance testing against relevant engineering and regulatory standards, rather than a clinical or AI/ML performance study.

{0}------------------------------------------------

510(k) SUMMARY

Invacare Corporation's Action Cat Scooter with DS60 Controller

K962583

DEC 1 8 1996

Submitter's Name, Address, Telephone Number, Contact Person and Date Prepared

Invacare Corporation 899 Cleveland Street Elyria, OH 44036-2125 Phone: (216) 329-6000 Facsimile: (216) 366-1803

Edward A. Kroll Contact Person: Director, TQM and Regulatory Affairs

Date Prepared: July 1, 1996

Name of Device and Name/Address of Sponsor

Action Cat Scooter with DS60 Controller

Invacare Corporation 899 Cleveland Street Elyria, OH 44036-2125 Phone: (216) 329-6000 Facsimile: (216) 366-9724

Common or Usual Name

Powered scooter

Classification Name

Motorized three-wheeled vehicle

Predicate Devices

The Action Cat Scooter with DS60 Controller ("Action Cat Scooter with DS60 Controller ") is substantially equivalent to Invacare Corporation's Cat Scooter (K941966).

{1}------------------------------------------------

Intended Use

The Action Cat Scooter with DS60 Controller is intended to be used to provide mobility to persons restricted to a seated position.

Technological Characteristics and Substantial Equivalence

A. Device Description

As indicated above, the Action Cat Scooter with DS60 Controller is intended for use to provide mobility to persons restricted to a seated position. The scooter has a total weight of 160 pounds (including batteries), and its overall width, track, and wheelbase are 24", 34", and 46", respectively. All upholstery on the device is flame rated to FMVSS302 and CMVSS302. The maximum grade is 9 degrees with a 300 pound load, and the leakage current is less than 100 amperes. The maximum load is 300 pounds, and the maximum speed for the scooter is 5 (±1) mph. The scooter does not have separate "slow," "normal," and "fast" speed control modes; instead, the speed of the vehicle simply is determined on a continuous range by how far the user pushes the speed control bar/tiller.

The braking system for the scooter is electromechanical. Activation of the throttle speed control (either forward or reverse), causes the engagement of an electromagnet which overcomes spring pressure and releases the brake. Releasing the throttle causes the motor control board to induce dynamic braking and reduce speed. Once motor revolution reaches zero, the electromagnet will release, allowing the spring pressure to apply the brake. As an additional feature, the scooter will not operate if the brake is disconnected. The brake is designed to hold a 400 pound load on a 15 degree incline. On level ground with dry conditions and a 300 pound load, braking time from a top speed of 6 mph to zero is 1 second and requires a distance of 5 feet.

The Action Cat Scooter with DS60 Controller uses two 12 volt gel cell batteries. The scooter's range on a standard charge varies according to temperature and battery condition, but the average range is approximately 25 miles. The front approach angle for the Action Cat Scooter with DS60 Controller is 71 degrees, and the rear departure angle is 13 degrees. At the scooter's center, the ground clearance from the chassis is 3.0". Likewise, the maximum curb clearance is 3.0". The breakover angle is 10 degrees, and the minimum radius at which the Action Cat Scooter with DS60 Controller will not tip (at maximum speed) is 6 feet.

The controller for the scooter is a Model DS60 system for DC motor control applications. The DS60 Controller is designed to operate with a nominal 24 volt battery input and to yield a maximum output current of 60 amperes. It also is designed to control a single conventional permanent magnet DC motor with a solenoid-controlled motor brake. The controller incorporates motor load compensation which provides precise motor control over a wide range of driving conditions, thereby maintaining the selected speed of the scooter at a constant level,

{2}------------------------------------------------

regardless of the surface type or grade on which the vehicle is driven. This feature ensures less roll-back when stopping the Action Cat Scooter on a slope. The correct level of load compensation depends on the type of motor used and the length of the wiring, and is easily set using the separate handheld DS Programmer.

The programmable features of the DS60 Controller include forward/reverse acceleration, forward/reverse deceleration, motor resistance, etc. It should be noted, however, that although the DS60 Controller for the modified Cat Scooter is programmable, all parameters for the controller will be set only by the factory (i.e., Invacare) prior to sale, and no modifications will be made by either the retailer or the user of the scooter. The DS100 Programmer will not be available for purchase.

The DS60 Controller is a single printed circuit board fixed to an aluminum base. A plastic vacuum-molded case protects the electronics of the DS60 Controller. The DS60 Controller also is protected against accidental reverse battery connection.

Several accessories are available through Invacare for the modified Action Cat Scooter. These options are: a basket, antitipper components, a flat-free insert, an extended throttle lever, a safety flag, a crutch/cane carrier, and a spare key set. The Action Cat Scooter with DS60 Controller also is available in a compact style which measures 43½ inches in length (versus 50" for the regular size scooter).

B. Substantial Equivalence

The predicate Cat Scooter also provides essentially the same specifications, functions, characteristics, and accessories as described above for the Action Cat Scooter with DS60 Controller. The predicate motorized three-wheeled vehicle is nearly identical to the Action Cat Scooter with DS60 Controller and has the same intended use. The following specifications for the predicate Cat Scooter are the same as those for the Action Cat Scooter with DS60 Controller:

  • ·Total weight;
    ·Track;

  • ·Wheelbase;
    ·Maximum speed;

  • ·Motor/gears:

  • ·Maximum grade;

  • ·Maximum load;

  • ·Leakage current;

  • ·Braking system;

  • ·Batteries;

•Front approach angle:

·Rear departure angle;

·Ground clearance;

·Breakover angle; and

{3}------------------------------------------------

• Minimum non-tipping radius (at maximum speed).

Although there are some differences between the Action Cat Scooter with DS60 Controller and its predicate, these differences are minor and raise no new questions of safety and effectiveness. The only significant difference between the two models is that the newer version has a digital controller while the predicate is equipped with an analog controller. Thus, unlike the digital controller for the modified Action Cat Scooter with DS60 Controller, the the controller for the predicate device was not programmable and did not utilize software. But even this disparity is small, as the DS60 only will be programmable by the factory (i.e., neither the dealers nor the users will be able to change the factory presets). Furthermore, both controllers have essentially identical input/output parameters and safety features.

Other more minor differences in the Action Cat Scooter with DS60 Controller versus the original Cat Scooter include the addition of a standard onboard charger, an increase in the labeled weight limit from 250 pounds to 300 pounds, the option of a compact model, and the addition of a height-adjustable seat. Thus, the differences in technological characteristics between the Action Cat Scooter with DS60 Controller and its predicate device are minor and do not present any new issues of safety or effectiveness.

Performance Data

As required by FDA's July 26, 1995 draft publication entitled "Guidance Document for the Preparation of Premarket Notification [510(k)] Applications for Mechanical and Powered Wheelchairs, and Motorized Three-Wheeled Vehicles", the Action Cat Scooter with DS60 Controller was tested in accordance with ISO EMC Draft Standard 7176-14 (Titled "Draft ISO EMC Group Proposal: Electromagnetic Compatibiliity Addition" And Dated April 3, 1995) for powered wheelchairs and motorized scooters. In all instances, the Action Cat Scooter with DS60 Controller met the required performance criteria and functioned as intended. The Action Cat Scooter with DS60 Controller also passed a number of performance tests performed voluntarily by Invacare.

§ 890.3800 Motorized three-wheeled vehicle.

(a)
Identification. A motorized three-wheeled vehicle is a gasoline-fueled or battery-powered device intended for medical purposes that is used for outside transportation by disabled persons.(b)
Classification. Class II (performance standards).