(27 days)
The device and accessories are indicated as a noninvasive aid in the examination and diagnosis of eye conditions and in the fitting of contact lenses. The indications are the same as those claimed for the predicate devices.
The Rodenstock brand RO 5000 and RO 4000 slitlamps are instruments used for eye examination and the fitting of contact lenses. Each device consists of a microscope combined with a light source that can be narrowed into a slit for illumination of the eye. Each is available with accessories to measure characteristics of the eye and to document actual shapes. The device is powered by 6.3 to 12v AC and 50-60 Hz.
This document is a 510(k) summary for medical device clearance, not a study report detailing acceptance criteria for an AI/device performance study. Therefore, the requested information regarding acceptance criteria, study design, expert involvement, and ground truth establishment cannot be extracted from the provided text.
The provided text describes two slitlamp devices, the Rodenstock RO 5000 and RO 4000, and their substantial equivalence to predicate devices (Haag-Streit 900 BQ and Topcon SL-2ED). It addresses the intended use, technological characteristics, and indications for use, stating they are "noninvasive aid in the examination and diagnosis of eye conditions and in the fitting of contact lenses."
There is no mention of:
- Specific quantitative acceptance criteria for device performance.
- Any study used to "prove" the device meets acceptance criteria in the context of a performance study (e.g., clinical trial, AI validation).
- Sample sizes for test sets or training sets.
- Data provenance or expert involvement for ground truth.
- Adjudication methods.
- MRMC studies or standalone algorithm performance.
- Types of ground truth beyond the general statement of "examination and diagnosis of eye conditions."
The 510(k) summary focuses on establishing substantial equivalence to legally marketed predicate devices, which generally involves comparing technical characteristics, indications for use, and safety, rather than presenting a performance study with explicit acceptance criteria as one would find for a novel AI or diagnostic algorithm.
{0}------------------------------------------------
JUL 25 1998
ﮐﺴﺎﻧ
510 (k) Summary
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR § 807.92.
- The submitter of this premarket notification is:
David M. Link, Vice President EXPERTech™ Associates, Inc. 100 Main Street, Suite 120 Concord, MA 01742-5307 (508) 371-0066 Telephone: Fax: (508) 371-1676
This Summary was prepared on May 31, 1996.
-
The name of the device is the Rodenstock RO 5000 and RO 4000 Slitlamp. Its common name is the slitlamp and the classification name is the AC-powered slitlamp biomicroscope.
-
The RO 5000 device is substantially equivalent to the Haag-Streit brand slitlamp 900® BQ and the RO 4000 device is substantially equivalent to the Topcon brand slitlamp model SL-2ED .
-
The Rodenstock brand RO 5000 and RO 4000 slitlamps are instruments used for eye examination and the fitting of contact lenses. Each device consists of a microscope combined with a light source that can be narrowed into a slit for illumination of the eye. Each is available with accessories to measure characteristics of the eye and to document actual shapes. The device is powered by 6.3 to 12v AC and 50-60 Hz.
-
The device and accessories are indicated as a noninvasive aid in the examination and diagnosis of eye conditions and in the fitting of contact lenses. The indications are the same as those claimed for the predicate devices.
-
The technological characteristics are the same or similar to those found with the predicate devices where the eye is examined by projecting light onto it. Additionally, standard accessories are used for tonometry, examining the vitreous and fundus of the eye and contact lens fitting as those claimed for the predicate devices.
000090
§ 886.1850 AC-powered slitlamp biomicroscope.
(a)
Identification. An AC-powered slitlamp biomicroscope is an AC-powered device that is a microscope intended for use in eye examination that projects into a patient's eye through a control diaphragm a thin, intense beam of light.(b)
Classification. Class II (special controls). The device, when it is intended only for the visual examination of the anterior segment of the eye, is classified as Group 1 per FDA-recognized consensus standard ANSI Z80.36, does not provide any quantitative output, and is not intended for screening or automated diagnostic indications, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9.