K Number
K962142
Date Cleared
1997-05-29

(360 days)

Product Code
Regulation Number
892.1560
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The SONOLINE Versa 555 ultrasound imaging system is intended for the following applications: General Radiology, Abdominal, Intraoperative (abdominal and neurosurgical), Small Parts, Transcranial, OB/GYN, Pelvic, Neonatal Cephalic, Urology, Vascular, Peripheral Vascular, and Transesophageal Echocardiography (TEE) applications.

The system also provides for the measurement of anatomical structures and for analysis packages that provide information that is used for clinical diagnosis purposes.

Diagnostic ultrasound imaging and Doppler analysis of the human body as follows: Cephalic Adult, Cephalic Neonatal, Cardiac Adult, Cardiac Pediatric.

Device Description

The SONOLINE Versa 555 is a general purpose, mobile, software-controlled, diagnostic ultrasound system with an on-screen display for thermal and mechanical values related to potential bioeffect mechanisms. Its function is to acquire ultrasound data and display it in B-Mode, M-Mode, Color Flow Modes, Pulsed (PW) Doppler Mode, Continuous (CW) Doppler Mode, or in a combination of modes, on a CRT display.

AI/ML Overview

The provided text is a 510(k) summary for the SONOLINE Versa 555 Diagnostic Ultrasound System. This document focuses on demonstrating substantial equivalence to predicate devices rather than providing a study on the device's clinical performance against specific acceptance criteria.

Therefore, the requested information regarding acceptance criteria and a study proving the device meets them, including details like sample size, data provenance, expert ground truth, adjudication methods, MRMC studies, standalone performance, and training set information, cannot be extracted from the provided text because such a study is not described.

The document details the device's technical specifications, intended uses, and compliance with safety standards and regulatory requirements for market clearance. It does not contain information about a clinical performance study with specific metrics.

Here's a breakdown of why each requested point cannot be answered from the provided text:

  1. A table of acceptance criteria and the reported device performance: This document does not present any clinical performance data or specific acceptance criteria for a clinical study. It refers to compliance with safety standards (UL, CSA, AIUM/NEMA, EEC, EN60601) and substantial equivalence to predicate devices.
  2. Sample size used for the test set and the data provenance: No clinical test set is described.
  3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: No ground truth establishment for a test set is described.
  4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: No test set or adjudication method is described.
  5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: The device described is a diagnostic ultrasound system, not an AI-based system, and no MRMC study is mentioned.
  6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: The device is a human-operated ultrasound system, not a standalone algorithm.
  7. The type of ground truth used (expert concensus, pathology, outcomes data, etc): No clinical ground truth is described in the context of device performance.
  8. The sample size for the training set: The document does not describe any machine learning or AI components with a training set.
  9. How the ground truth for the training set was established: Not applicable, as no training set is described.

In summary, the provided 510(k) summary focuses on regulatory compliance and technical similarity to previously cleared devices, not on a clinical performance study with specific acceptance criteria and outcome metrics.

{0}------------------------------------------------

MAY 2 9 1997

510(K) SUMMARY

容 时间: 前一条

1

K962142

SONOLINE Versa 555 Diagnostic Ultrasound System

This summary of safety and effectiveness is provided as part of this Premarket Notification in compliance with the Safe Medical Device Act of 1990 revisions to 21 CFR, Part 807.92, Content and Format of a 510(k) Summary.

Submitted By: 1. Siemens Medical Systems, Inc., Ultrasound Group 22010 SE 51st Street . Issaquah, WA 98027-7002

Contact Person: Steve Hesler Manager of Regulatory Affairs (206) 557-1629

Date Prepared: May 30, 1996

  • Proprietary Name: 2. SONOLINE Versa 555 Diagnostic Ultrasound System
    Common/ Usual Name: Diagnostic Ultrasound System with Accessories

Classification Name:

Ultrasonic Pulsed Doppler Imaging System (Product Code 90 YIN, 21 CFR 892.1550)

Predicate Device: 3.

Siemens SONOLINE Versa Diagnostic Ultrasound System (K945773), 8/7/95. Siemens SONOLINE Elegra Diagnostic Ultrasound System (K945072), 11/21/95.

Device Description: 4.

The SONOLINE Versa 555 is a general purpose, mobile, software-controlled, diagnostic ultrasound system with an on-screen display for thermal and mechanical values related to potential bioeffect mechanisms. Its function is to acquire ultrasound data and display it in B-Mode, M-Mode, Color Flow Modes, Pulsed (PW) Doppler Mode, Continuous (CW) Doppler Mode, or in a combination of modes, on a CRT display .

{1}------------------------------------------------

The SONOLINE ® Versa 555 has been designed to meet the following product safety standards:

  • UL 2601, Safety Requirements for Medical Equipment ●
  • CSA 22.2 No. 601-1, Safety Requirements for Medical Equipment ●
  • Standard for Real Time Display of Thermal and Mechanical Indices on . Diagnostic Ultrasound Equipment, AIUM/NEMA, 1992.
  • 93/94/EEC Medical Devices Directive .
  • EN60601 = (IEC 601-1-1 + IEC 601-1-2), Safety and EMC , Requirements for . Medical Equipment
    1. Intended Uses:

The SONOLINE Versa 555 ultrasound imaging system is intended for the following applications: General Radiology, Abdominal, Intraoperative (abdominal and neurosurgical), Small Parts, Transcranial, OB/GYN, Pelvic, Neonatal Cephalic, Urology, Vascular, Peripheral Vascular, and Transesophageal Echocardiography (TEE) applications.

The system also provides for the measurement of anatomical structures and for analysis packages that provide information that is used for clinical diagnosis purposes.

6. Technological Comparison to Predicate Device:

The SONOLINE Versa 555 is similar to the SONOLINE Versa in that both incorporate software controlled electronics to transmit ultrasonic pulses, via a transducer, into a patient, then receive return (echo) pulses and to convert those pulses into a visual display, to be provide information for use in the diagnosis of various disease states as well as normal conditions such as pregnancy and physical development. The operating principles of both systems are identical. However, the SONOLINE Versa 555 supports phased array transducers.

Both systems incorporate an on-screen display of Mechanical (MI) and Thermal (IT) Indices. in compliance with the Standard for Real Time Display of Thermal and Mechanical Indices on Diagnostic Ultrasound Equipment, AIUM/NEMA, 1992.

End of 510(k) Summary

Page 2

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with its wings spread, facing to the right. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" are arranged in a circular pattern around the eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

MAY 2 9 1997

Steve Hesler Manager Regulatory Affairs Siemens Medical Systems 22010 S.E. 51st St.: . . . - -- ---Issaquah, WA 98027-7002

Re: K962142

Sonoline Versa 555 Dated: April 10, 1997 Received: April 11, 1997 Regulatory class: II 21 CFR 892.1550/Procode: 90 IYO

Dear Mr. Hesler:

We have reviewed your section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug and Cosmetic Act. You may, therefore, market the device, subject to the general controls provisions Act (Act). The general controls provisions of the Act include requirements for registration, listing of devices, good manufacturing practices, labeling, and prohibitions against misbranding and adulteration.

This determination of substantial equivalence applies to the following transducers intended for use with the Sonoline Versa 555, as described in your premarket notification:

Transducer Model Number 2.5 MHZ 2.5P20 Phased Linear Array 3.5 MHZ 3.5P14 Phased Linear Array 3.5 MHZ 3.5C20 Curved Array 3.5 MHZ 3.5C40 Curved Array 3.5 MHZ 3.5C60 Curved Array 3.5 MHZ 3.5C80 Curved Array 5.0 MHZ TEE 5.0 MHZ 5.0P10 Phased Linear Array 5.0 MHZ 5.0L45 Linear Array 5.0 MHZ 5.0C50 Curved Array

{3}------------------------------------------------

and the the

5.0 MHZ 5.0L90 Linear Array 6.5 MHZ 6.5F13 Curved Array 6.5 MHZ 6.5EV 13 Curved Array 7.5 MHZ 7.5C30 Curved Array 7.5 MHZ 7.5L40 Linear Array 7.5 MHZ 7.5L501 Linear Array 7.5 MHZ 7.5L50Q Linear Array 7.5 MHZ 7.5L70 Linear Array 10.0 MHZ 10.0L25 Linear Array

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the FDA will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification does not affect any obligation you may have under sections 531 and 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.

Please be advised that the determination above is based on the fact that no medical devices have been demonstrated to be safe and effective for in vitro fertilization or percutaneous umbilical blood sampling, nor have any devices been marketed for these uses in interstate commerce prior to May 28, 1976, or reclassified into class I (General Controls) or class II (Special Controls). FDA considers devices specifically intended for in vitro fertilization and percutaneous umbilical blood sampling to be investigational, and subject to the investigational device exemptions (IDE) regulations. 21 CFR, Part 812. Therefore, your product labeling must be consistent with FDA's position on this use.

This determination of substantial equivalence is granted on the prior to shipping the first device, you submit a postclearance special report. This report should contain complete information, including acoustic output measurements based on production line devices, requested in Appendix G, (enclosed) of the Center's February 17, 1993 "Revised 510(k) Diaguestic Ultrasound Guidance for 1993." If the special report is incomplete or contains unacceptable values (e.g., acoustic output greater than approved levels), then the 510(k) clearance may not apply to the production units which as a result may be considered adulterated or misbranded.

The special report should reference the manufacturer's 510(k) number. It should be clearly and prominently marked "ADD-TO-FILE" and should be submitted in duplicate to:

Food and Drug Administration Center for Devices and Radiological Health Document Mail Center (HFZ-401) 9200 Corporate Boulevard Rockville, Maryland 20850

{4}------------------------------------------------

Page 3 - Mr. Steve Hesler

2011 - 11

This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 If you desire specific abvice for your device on our labeling (21 CFR Par 80) . Additionally 609 .
for in vitro diagnostic device of your device of Compiance at (30) . 94-459 questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or at (301) 443-6597 or at its Internet address "dsmo@fdadr.cdrh.fda.gov".

If you have any questions regarding the content of this letter, please contact Maureen Butler at (301) 594-1212.

Sincerely yours,

David A. Sejerson
Lillian Yin, Ph.D.

Director, Division of Reproductive, Abdominal, Ear, Nose and Throat, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure(s)

{5}------------------------------------------------

Ultrasound Device Indications Statement

K962142 510 (k) Number (if known)

Device Name

2.5P20 transducer for use with the SONOLINE Versa 555

Indications For Use

Diagnostic ultrasound imaging and Doppler analysis of the human body as follows:

Mode of Operation
ClinicalApplicationBMPWDCWDC(Color Maps)Combined(B,C,D)Other(Specify)
Ophthalmic
Fetal
Abdominal
IntraoperativeAbdominalNeurosurgical
Pediatric
Small Organ
CephalicAdultNeonatal
CardiacAdultPediatric
Trans-esophageal
Trans-rectal
Trans-vaginal
Intra-luminal
Trans-urethral
Peripheralvessel
Laparoscopic

(Other Indications or Modes)


Concurrence of CDPH, Office of Device Evaluation (ODE)

Prescription Use Per 21 CFR 801 109)


Elinor W. Hepburn

(Division Sign-Off) Division of Reproductive, Abdominal, ENT, and Radiological Devices

5.0 k) Number K962142

§ 892.1560 Ultrasonic pulsed echo imaging system.

(a)
Identification. An ultrasonic pulsed echo imaging system is a device intended to project a pulsed sound beam into body tissue to determine the depth or location of the tissue interfaces and to measure the duration of an acoustic pulse from the transmitter to the tissue interface and back to the receiver. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.(b)
Classification. Class II (special controls). A biopsy needle guide kit intended for use with an ultrasonic pulsed echo imaging system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.