K Number
K961716

Validate with FDA (Live)

Date Cleared
1996-09-19

(140 days)

Product Code
Regulation Number
870.5150
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The catheters are intended for use in the removal of arterial emboli and thrombi during embolectomy and thrombectomy.

Device Description

The Vaso-Safe Arterial Embolectomy Catheter is a single lumen nylon tube with a natural latex balloon attached to a distal end and a stopcock affixed to the proximal end. It will be packaged with a syringe. The catheter will be available in 5 french sizes and 3 lengths.

AI/ML Overview

This document describes a medical device, the "Vaso-Safe Arterial Embolectomy Catheter," and its classification, description, and intended use. However, it does not contain any information regarding acceptance criteria or a study proving the device meets acceptance criteria.

Therefore, I cannot provide the requested information. The provided text is a summary of the device for regulatory purposes, not a clinical study report.

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows a sequence of handwritten characters. The characters appear to be a mix of letters and numbers, specifically 'K961716'. The handwriting style is somewhat stylized, with distinct strokes and curves forming each character. The image is in black and white, with the characters appearing in black against a white background.

SAFETY and EFFECTIVENESS SUMMARY

PROPRIETARY NAME:

P 19 Kids

Vaso-Safe Arterial Embolectomy Catheter

COMMON USUAL NAME:

Embolectomy Catheter

CLASSIFICATION:

Class II

CLASSIFICATION NUMBER:

74 DXE

DEVICE DESCRIPTION:

The Vaso-Safe Arterial Embolectomy Catheter is a single lumen nylon tube with a natural latex balloon attached to a distal end and a stopcock affixed to the proximal end. It will be packaged with a syringe. The catheter will be available in 5 french sizes and 3 lengths.

The catheters are intended for use in the removal of arterial emboli and thrombi during embolectomy and thrombectomy.

The catheter, with the balloon deflated, is advanced into the vessel beyond the clot. The balloon is inflated with sterile solution. The catheter is withdrawn pulling the embolism with it, thus removing it from the artery.

The materials used on the Vaso-Safe Arterial Embolectomy Catheters have been used for years on other models of Ideas for Medicine, Inc. catheters except the suture, which has been certified to USP grade. Other catheter materials have been certified to meet the requirements of USP Class VI tests. Every lot is supplied sterile and nonpyrogenic.

SUBSTANTIAL EQUIVALENCE:

The intended use of these devices is to remove arterial emboli and thrombi. This use is identical to the Fogarty Embolectorny Catheter. The Robicsek Angiography Embolectomy Catheters are for arterial emboli and thrombi removal but provide the ability to irrigate concurrent with removal.

§ 870.5150 Embolectomy catheter.

(a)
Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to another.(b)
Classification. Class II (performance standards).