K Number
K250475

Validate with FDA (Live)

Date Cleared
2025-05-27

(97 days)

Product Code
Regulation Number
890.3860
Age Range
All
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

This Electric Wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

Device Description

The product is intended only carry one person and used as a means of transportation for the old and infirm who have difficulty in moving.

The maximum occupant mass is 100kg.

The Electric Wheelchair is a battery powered four wheeled vehicle. It consists one Lithium battery with an off-board battery charger, frame, controller, motors, seat, back support, control device (including the battery power indicator, ON/OFF button, horn button, speed indicator, speed control button, joystick, Battery charger socket), arm supports, two rear wheels, two casters(front wheels), Foot support, anti-tip devices.

The wheelchair can easily fold and unfold for transportation or storage.

AI/ML Overview

The provided text describes the FDA 510(k) clearance for an Electric Wheelchair. However, it does not include information about acceptance criteria for a device performance study in the typical sense of a clinical or analytical performance study with specific metrics like sensitivity, specificity, or accuracy.

Instead, the "acceptance criteria" for this device are demonstrated through adherence to a comprehensive set of international standards for wheelchairs. The study that proves the device meets these criteria is a series of non-clinical tests conducted against these standards.

Here's an analysis based on the provided document:


Acceptance Criteria and Reported Device Performance

The acceptance criteria for the Electric Wheelchair are largely defined by compliance with a comprehensive set of ISO and IEC standards related to wheelchairs. The reported device performance is demonstrated by its successful adherence to these standards.

Acceptance Criterion (Standard)Reported Device Performance
Biocompatibility: ISO 10993-1: 2018 (Biological Evaluation of Medical Devices)Complies with the standard.
Static Stability: ISO 7176-1:2014 (Determination of static stability)Complies with the standard.
Dynamic Stability: ISO 7176-2:2017 (Determination of dynamic stability of electrically powered wheelchairs)Complies with the standard.
Brake Effectiveness: ISO 7176-3:2012 (Determination of effectiveness of brakes)Complies with the standard. (Note: Subject device's braking distances are similar to or shorter than the predicate.)
Energy Consumption/Range: ISO 7176-4:2008 (Energy consumption for determination of theoretical distance range)Complies with the standard. (Note: Travel distances are similar to the predicate.)
Overall Dimensions, Mass, Maneuvering Space: ISO 7176-5:2008 (Determination of overall dimensions, mass and manoeuvring space)Complies with the standard. (Note: Specific values for dimensions and mass are provided and deemed acceptable despite differences.)
Speed, Acceleration, Deceleration: ISO 7176-6:2018 (Determination of maximum speed, acceleration and deceleration)Complies with the standard. (Note: Max speeds are specified and deemed acceptable.)
Seating & Wheel Dimensions: ISO 7176-7:1998 (Measurement of seating and wheel dimensions)Complies with the standard.
Static, Impact & Fatigue Strengths: ISO 7176-8:2014 (Requirements and test methods for static, impact and fatigue strengths)Complies with the standard.
Climatic Tests: ISO 7176-9:2009 (Climatic tests for electric wheelchairs)Complies with the standard.
Obstacle-Climbing Ability: ISO 7176-10:2008 (Determination of obstacle-climbing ability)Complies with the standard. (Note: Obstacle climbing ability is specified and deemed acceptable.)
Test Dummies: ISO 7176-11:2012 (Test dummies)Complies with the standard.
Coefficient of Friction: ISO 7176-13:1989 (Determination of coefficient of friction of test surfaces)Complies with the standard.
Power and Control Systems: ISO 7176-14:2008 (Power and control systems for electrically powered wheelchairs and scooters - Requirements and test methods)Complies with the standard.
Information Disclosure, Documentation and Labeling: ISO 7176-15:1996 (Requirements for information disclosure, documentation and labeling)Complies with the standard.
Resistance to Ignition of Postural Support Devices: ISO 16840-10: 2021 (Wheelchair seating - Part 10: Resistance to ignition of postural support devices)Complies with the standard; flame-retardant test carried out.
Electromagnetic Compatibility: ISO 7176-21:2009 (Electromagnetic compatibility of electrically powered wheelchairs) & IEC 60601-1-2:2014+A1:2020 (Electromagnetic disturbances)Complies with the standard.
Batteries and Chargers: ISO 7176-25:2013 (Batteries and chargers for powered wheelchairs) & IEC 62133-2: 2017 (Safety requirements for lithium systems)Complies with the standard.
Maximum Safe Operational Incline: (Implicit in stability standards like ISO 7176-2)6° to 10° depending on model, deemed acceptable as stability is evaluated.
Max Loading Weight: (Implicit in strength standards like ISO 7176-8)100kg, deemed acceptable as performance validated.

Study Details:

  1. Sample size used for the test set and the data provenance:

    • The document states "Non-clinical tests were conducted to verify that the proposed device met all design specifications." This typically implies testing of a representative sample of the manufactured device models. Specific numbers for each test (e.g., how many units were tested for static stability) are not provided.
    • Data provenance: The tests were performed by the manufacturer, Ningbo Baichen Medical Devices Co., Ltd., which is located in China. The data would be considered retrospective in the sense that the testing was completed prior to the 510(k) submission, but it's prospective in relation to the design validation process.
  2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This question is not applicable in the context of this device and study type. The "ground truth" for non-clinical performance (e.g., static stability, brake effectiveness) is defined by the technical specifications and limits set forth in the international standards (ISO, IEC). The testing involves objective measurements rather than expert interpretation of data like in an image-based diagnostic study.
  3. Adjudication method for the test set:

    • This question is not applicable. Adjudication typically refers to resolving discrepancies in expert interpretations (e.g., 2+1 means 2 out of 3 experts agree, 3+1 means 3 out of 4 agree, with a fourth to resolve ties). Since these are objective physical performance tests against established numerical standards, there is no expert adjudication process. The results are either within the standard's limits or they are not.
  4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • This is not applicable. This is an Electric Wheelchair, a physical medical device, not an AI software intended for interpretation by human readers. Therefore, an MRMC study is not relevant.
  5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • This is not applicable. This is a physical medical device. While it contains an "Electronic controller" (SYC-PM30), the performance described (e.g., speeds, stability, braking) is a property of the integrated physical device, not a standalone algorithm. Software validation was performed for the control system, as mentioned under the difference D#11, but this is part of the overall device's non-clinical testing, not a standalone algorithm performance study in the context of diagnostic AI.
  6. The type of ground truth used:

    • The "ground truth" for this device's performance is established by international consensus standards (ISO and IEC). These standards define the acceptable performance parameters and test methods for electric wheelchairs to ensure their safety and effectiveness.
  7. The sample size for the training set:

    • This question is not applicable. This is a physical medical device. There is no "training set" in the context of machine learning or AI algorithms for this type of device. The design and validation are based on engineering principles and compliance with established standards.
  8. How the ground truth for the training set was established:

    • This question is not applicable, as there is no training set for this device.

In summary, the provided document details a non-clinical performance study demonstrating substantial equivalence through rigorous adherence to internationally recognized safety and performance standards for electric wheelchairs. The specific metrics are defined by these standards, and the device's performance met these criteria through objective physical testing.

FDA 510(k) Clearance Letter - Electric Wheelchair

Page 1

U.S. Food & Drug Administration
10903 New Hampshire Avenue
Silver Spring, MD 20993
www.fda.gov

Doc ID # 04017.07.05

May 27, 2025

Ningbo Baichen Medical Devices Co., Ltd
℅ Luna Hu
Official Correspondent
Shanghai SUNGO Management Consulting Co., Ltd.
Room 1401, Dongfang Building, 1500# Century Ave
Shanghai, 200122
China

Re: K250475
Trade/Device Name: Electric Wheelchair (BC-EA5516, BC-EC8002, BC-EC8003, BC-EALD3)
Regulation Number: 21 CFR 890.3860
Regulation Name: Powered Wheelchair
Regulatory Class: Class II
Product Code: ITI
Dated: April 30, 2025
Received: February 21, 2025

Dear Luna Hu:

We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Page 2

K250475 - Luna Hu Page 2

Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).

Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.

All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-

Page 3

K250475 - Luna Hu Page 3

assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

Tushar Bansal -S

for Heather Dean, PhD
Assistant Director, Acute Injury Devices Team
DHT5B: Division of Neuromodulation and
Physical Medicine Devices
OHT5: Office of Neurological and
Physical Medicine Devices
Office of Product Evaluation and Quality
Center for Devices and Radiological Health

Enclosure

Page 4

DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration

Form Approved: OMB No. 0910-0120
Expiration Date: 07/31/2026
See PRA Statement below.

Indications for Use

Submission Number (if known)
K250475

Device Name
Electric Wheelchair (BC-EA5516, BC-EC8002, BC-EC8003, BC-EALD3)

Indications for Use (Describe)
This Electric Wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position

Type of Use (Select one or both, as applicable)
☐ Prescription Use (Part 21 CFR 801 Subpart D)
☒ Over-The-Counter Use (21 CFR 801 Subpart C)

CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.
DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services
Food and Drug Administration
Office of Chief Information Officer
Paperwork Reduction Act (PRA) Staff
PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

Page 5

510(k) Summary

K250475

Document Prepared Date: 04/30/2025

1. Applicant

Company name: NINGBO BAICHEN MEDICAL DEVICES CO., LTD

Address: Room 2101, No.666 Taikang Middle Road, Yinzhou District, Ningbo City, Zhejiang, 315000, CHINA

Contact Person: Mr. Wu Xiaolong
Tel: alan@baichen.ltd

Submission Correspondent:

Primary Contact: Luna Hu
Shanghai SUNGO Management Consulting Co., Ltd.
14th Floor, Dongfang Building, 1500# Central Ave., Shanghai 200122, China
Tel: 0086-21-58817802
Email: liu.hu@sungoglobal.com

Secondary Contact: Raymond Luo
Shanghai SUNGO Management Consulting Co., Ltd.
14th Floor, Dongfang Building, 1500# Central Ave., Shanghai 200122, China
Tel: 0086-21-68828050
Email: zxfda@sungoglobal.com

2. Device

Trade name: Electric Wheelchair
Classification name: Powered wheelchair
Model: BC-EA5516, BC-EC8002, BC-EC8003, BC-EALD3

Regulatory Information
Classification: Class II
Product code: ITI
Regulation Number: 890.3860
Review Panel: Physical Medicine

3. Predicate Device

Manufacturer: Zhejiang Innuovo Rehabilitation Devices Co., Ltd.
Product Name: Power wheelchair (Model: W5538)
510(K) #: K242471

Page 6

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

4. Indication for Use

This Electric Wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

5. Device Description

The product is intended only carry one person and used as a means of transportation for the old and infirm who have difficulty in moving.

The maximum occupant mass is 100kg.

The Electric Wheelchair is a battery powered four wheeled vehicle. It consists one Lithium battery with an off-board battery charger, frame, controller, motors, seat, back support, control device (including the battery power indicator, ON/OFF button, horn button, speed indicator, speed control button, joystick, Battery charger socket), arm supports, two rear wheels, two casters(front wheels), Foot support, anti-tip devices.

The wheelchair can easily fold and unfold for transportation or storage.

6. Non-clinical Test Conclusion

Non-clinical tests were conducted to verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device. The test results demonstrated that the proposed device complies with the following standards:

  • ISO 10993-1: 2018 Biological Evaluation of Medical Devices -- Part 1: Evaluation and testing within a risk management process
  • ISO 7176-1:2014, Wheelchairs - Part 1: Determination of static stability
  • ISO 7176-2:2017, Wheelchairs - Part 2: Determination of dynamic stability of electrically powered wheelchairs
  • ISO 7176-3:2012, Wheelchairs - Part 3: Determination of effectiveness of brakes
  • ISO 7176-4:2008, Wheelchairs - Part 4: Energy consumption of electric wheelchairs and scooters for determination of theoretical distance range
  • ISO 7176-5:2008, Wheelchairs - Part 5: Determination of overall dimensions, mass and manoeuvring space
  • ISO 7176-6:2018, Wheelchairs - Part 6: Determination of maximum speed, acceleration and deceleration of electrically powered wheelchairs
  • ISO 7176-7:1998, Wheelchairs - Part 7: Measurement of seating and wheel dimensions
  • ISO 7176-8:2014, Wheelchairs -Part 8: Requirements and test methods for static, impact and fatigue strengths
  • ISO 7176-9:2009, Wheelchairs - Part 9: Climatic tests for electric wheelchairs
  • ISO 7176-10:2008, Wheelchairs - Part 10: Determination of obstacle-climbing ability of electrically powered wheelchairs
  • ISO 7176-11:2012 Wheelchairs - Part 11: Test dummies

Page 7

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

  • ISO 7176-13:1989, Wheelchairs - Part 13: Determination of coefficient of friction of test surfaces
  • ISO 7176-14:2008, Wheelchairs - Part 14: Power and control systems for electrically powered wheelchairs and scooters - Requirements and test methods
  • ISO 7176-15:1996, Wheelchairs - Part 15: Requirements for information disclosure, documentation and labeling
  • ISO 7176-25:2013 Wheelchairs - Part 25: Batteries and chargers for powered wheelchairs
  • ISO 16840-10: 2021 Wheelchair seating - Part 10: Resistance to ignition of postural support devices - Requirements and test method
  • ISO 7176-21:2009 Wheelchairs - Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargers
  • IEC 60601-1-2:2014+A1:2020 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
  • IEC 62133-2: 2017: Secondary cells and batteries containing alkaline or other non-acid electrolytes -Safety requirements for portable sealed secondary cells, and for batteries made from them, for use inportable applications - Part 2: Lithium systems

7. Clinical Test Conclusion

No animal study and clinical studies are available for our device. Clinical testing was not required to demonstrate the substantial equivalence of the electric wheelchair to its predicate device.

8. Comparison technological characteristics with the predicate device

AttributeSubject devicePredicate deviceResults
510(k) numberK250475K242471/
ManufacturerNINGBO BAICHEN MEDICAL DEVICES CO., LTDZhejiang Innuovo Rehabilitation Devices Co., Ltd./
Proprietary name, modelElectric Wheelchair BC-EA5516, BC-EC8002, BC-EC8003, BC-EALD3Power Wheelchair W5538/
Device classification nameClass IIClass IISame
Classification regulations21 CFR 890. 386021 CFR 890. 3860Same
Product codeITIITISame
Indication for useThis Electric Wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.The Power Wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.Same
Intended userdisabled people with mobility difficulties and elderly peopledisabled people with mobility difficulties and elderly peopleSame

Page 8

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

AttributeSubject devicePredicate deviceResults
Use conditionindoor and outdoor useindoor and outdoor useSame
Number of wheels6, including two front wheels and two rear wheels, two anti-tip wheels6, including two front wheels and two rear wheels, two anti-tip wheelsSame
Function of wheelsFront wheels: driven wheels suitable for rotation, acceleration, retrogradeRear wheels: driving wheels to control the speed and directionAnti-tip wheels: preventing the wheelchair from tipping turning over when driving on the slope.Non-adjustable.Front wheels: driven wheels suitable for rotation, acceleration, retrogradeRear wheels: driving wheels to control the speed and directionAnti-tip wheels: preventing the wheelchair from tipping turning over when driving on the slope.Non-adjustable.Same
Movement control methodBy Joystick controlBy Joystick controlSame
Driving systemDirect drive on the rear wheelsDirect drive on the rear wheelsSame
Brake systemAutomatic electromagnetic brake systemAutomatic electromagnetic brake systemSame
MotorBrushless DC motor; 24VDC; 250W; 2pcsBrushless DC motor; 24VDC; 250W; 2pcsSame

Differences

AttributeSubject devicePredicate deviceResults
Main frame materialBC-EA5516 and BC-EALD3: Aluminium alloy with ABS coatingBC-EC8002 and BC-EC8003: Carbon fiber with PUR coatingMagnesium alloy materialD#1
Total massBC-EA5516: 27kgBC-EC8002: 20kgBC-EC8003: 16kgBC-EALD3: 20kg19kgD#2
Front wheel size/typeBC-EA5516: Solid tire, 8 inchBC-EC8002: Solid tire, 6 inchBC-EC8003: Solid tire, 6 inchBC-EALD3: Solid tire, 8 inch6.8" x 1.3"/PU Solid tireD#3
Rear wheel size/typeBC-EA5516: Pneumatic tire, 12 inchBC-EC8002: Solid tire, 8 inchBC-EC8003: Solid tire, 11 inchBC-EALD3: Solid tire, 12 inch10.5″x 1.4″/ PU Solid tire
Max speed forward (km/h)BC-EA5516: 6.48BC-EC8002: 6.48BC-EC8003: 5.76BC-EALD3: 6.84Up to 6.1 km/h (1.7 m/s)D#4

Page 9

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

AttributeSubject devicePredicate deviceResults
Max speed backward (km/h)BC-EA5516: 3.24BC-EC8002: 3.24BC-EC8003: 2.88BC-EALD3:3.24Less than 3 km/h (0.6m/s)
Maximum safe operational incline degreeBC-EA5516, BC-EC8002 and BC-EC8003: 10°BC-EALD3: 6°10°SameD#5
Braking distanceBC-EA5516: 1.2mBC-EC8002: 1.2mBC-EC8003: 0.7mBC-EALD3: 0.6m1.2mSameD#6
Batteryli-ion battery pack; rechargeableBC-EA5516: 24V12AhBC-EC8002: 24V12AhBC-EC8003: 24V10AhBC-EALD3:XWE2410-Bli-ion battery pack; rechargeable, 24 VDC 12AhSameD#7
Battery chargerOff-board chargerInput: 100-240V, 50/60Hz, 1.5AOutput: 24 V, 2AOff-board chargerInput: 100-240V, 50/60Hz, 1.1AOutput: 24 V, 2AD#8
Max loading weight100kg120kgD#9
Maximum distance of travel on the fully charged battery (km)BC-EC8003: 15BC-EA5516: 15.7BC-EC8002: 15.3BC-EALD3: 18.115SameD#10
Electronic controllerSYC-PM30 ControllerDZWN2435-BWL ControllerD#11
Turning Radius (mm)BC-EA5516: 1000BC-EC8002: 850BC-EC8003: 950BC-EALD3: 850900D#12
Maximum obstacle climbing (mm)BC-EA5516: 40BC-EC8002, BC-EC8003 and BC-EALD3: 2025D#13

Difference analysis:

D#1: Different material used for frame, that such difference will not impact the safety and effectiveness of the subject device as the performance tests are conducted according to ISO 7176 series.

D#2: Different frame material caused different weight of the wheelchair. This difference will not raise any new safety and effectiveness concerns.

D#3: Minor difference on dimension of driven wheel will not cause different performance.

Page 10

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

D#4: Minor difference on max. forwarding and back warding speeds will not cause different performance. All safety and performance have been validated with the maximum rated weight dummy.

D#5: Minor difference on safe operational incline degree will not cause new safety and effectiveness concerns are raised as both the static and dynamic stability under specific inclining degree have been evaluated according to standard ISO 7176 series.

D#6: Minor difference on braking distance will not cause different performance. Shorter distance for braking will be more safety.

D#7: Minor difference on battery capacity will not cause different performance. This difference will not raise any new safety and effectiveness concerns.

D#8: Minor difference on the input current of the charger which will not cause new safety and effectiveness concerns raised.

D#9: Minor difference on loading weight will not cause different performance. All safety and performance have been validated according to ISO 7176 series.

D#10: Minor difference on travel distance will not cause different performance. This difference will not raise any new safety and effectiveness concerns.

D#11: Similar controller is used, both the control system, including the joystick controller, the electromagnetic brakes and the user interface are similar. The joystick controls the directions and speed of movement, and when the joystick is released, the powered wheelchair will slow down to stop and the brakes will automatically re-engage. The controller also provides the battery status displaying and abnormal condition displaying. Both of the control systems are evaluated according to standard ISO 7176-14 and software validation requirement and there are no new safety and effectiveness concerns due to the difference.

D#12: The minor difference in the turning radius is caused by different size of wheelchair and may cause a little bit inconvenience when it turns in a narrow space while the minor difference will not raise any new safety and effectiveness concerns.

D#13: Minor difference in the obstacle climbing will not impact the safety and effectiveness of the subject device.

9. Summary of substantial equivalence discussion

The electric wheelchair complied with the requirements of ISO 7176-1:2014, ISO 7176-2:2017, ISO 7176-3:2012, ISO 7176-4:2008, ISO 7176-5:2008, ISO 7176-6:2018, ISO 7176-7:1998, ISO 7176-8:2014, ISO 7176-9:2009, ISO 7176-10:2008, ISO 7176-11:2012, ISO 7176-13:1989, ISO 7176-14:2022, ISO 7176-15:1996, ISO 16840-10:2021, ISO 7176-21:2009, ISO 7176-22:2014, ISO10993-1:2018, IEC60601-1-2: 2020.

The indications for use for both devices are the same. Mainframes of two devices are folded by way of front and rear close. The design principles of the controller and Driving system are the same, and both meet the requirements of the ISO 7176-14. Software validation is carried out on both control systems. Brake system and speed control are designed in the same way as well, and both meet the requirements of the ISO 7176-3. Turning radius, maximum obstacle climbing and Maximum safe operational incline are slightly different while such differences will not impact the safety and effectiveness of the subject device or raise new safety and effectiveness concerns as well as both meet the requirements of the ISO 7176-2 and ISO 7176-10.

The flame-retardant test of the seat cushion/ backrest of both subject device and predicate device is carried out according to the ISO 16840-10 test. Therefore, both devices are assured to be under the same safety level.

Page 11

NINGBO BAICHEN MEDICAL DEVICES CO., LTD

In conclusion, the technological characteristics, features, specifications, materials, mode of operation, and intended use of the device substantially equivalent to the predicate devices quoted above. The differences between the subject device and predicate devices do not raise new issues of safety or effectiveness. The differences between the subject device and predicate devices do not raise new issues of safety or effectiveness.

10. Conclusion

The conclusions drawn from the nonclinical tests demonstrate that the subject device is as safe, as effective, and performs as well as the legally marketed predicate device K242471.

§ 890.3860 Powered wheelchair.

(a)
Identification. A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.(b)
Classification. Class II (performance standards).