# FDA 510(k) Clearance Letter - uWS-Angio Pro
## Page 1
**U.S. Food & Drug Administration**  
10903 New Hampshire Avenue  
Silver Spring, MD 20993  
www.fda.gov
**Doc ID # 04017.08.00**
September 24, 2025
Shanghai United Imaging Healthcare Co., Ltd.  
℅ Xin Gao  
RA Manager  
No. 2258 Chengbei Rd. Jiading District  
SHANGHAI, 201807  
CHINA
**Re: K250045**  
**Trade/Device Name:** uWS-Angio Pro  
**Regulation Number:** 21 CFR 892.2050  
**Regulation Name:** Medical Image Management And Processing System  
**Regulatory Class:** Class II  
**Product Code:** LLZ  
**Dated:** January 6, 2025  
**Received:** August 25, 2025
Dear Xin Gao:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
## Page 2
**K250045 - Xin Gao Page 2**
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-
## Page 3
**K250045 - Xin Gao Page 3**
assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
**Lu Jiang, Ph.D.**  
Assistant Director  
Diagnostic X-Ray Systems Team  
DHT8B: Division of Radiological Imaging Devices and Electronic Products  
OHT8: Office of Radiological Health  
Office of Product Evaluation and Quality  
Center for Devices and Radiological Health
Enclosure
## Page 4
**FORM FDA 3881 (8/23) Page 1 of 1**
**DEPARTMENT OF HEALTH AND HUMAN SERVICES**  
**Food and Drug Administration**
**Indications for Use**
Form Approved: OMB No. 0910-0120  
Expiration Date: 07/31/2026  
See PRA Statement below.
**510(k) Number (if known):** K250045  
**Device Name:** uWS-Angio Pro
### Indications for Use (Describe)
The uWS-Angio Pro is a post-processing software based on the uWS-Angio Basic for viewing, processing, evaluating and analyzing CT, MR, 3D XA images, and overlaying 2D medical images to support image guidance during interventional procedures. It has the following application:
The uWS-Angio Pro uTarget view application is intended to provide tools for adding the trajectory to the lesion. It also supports overlay of 3D datasets on 2D fluoroscopy images.
The uWS-Angio Pro uEmbo View application is intended to provide users with tools for planning and guiding interventional procedures. It offers a suite of features to mark targets, detect feeder vessels, and overlay the 3D image with the feeders and the corresponding anatomical X-ray image. When the overlay function is activated, it supports automatic 2D-3D image registration specifically for head neuroimaging, while the manual registration function is not restricted to any specific anatomical region.
The uWS-Angio Pro uCardiac View application is intended to provide users tools to plan and guide the interventional procedures. This application can use CT angiography images for vascular access analysis, aortic root analysis and angle management, and overlay registration display with 2D XA images.
### Type of Use (Select one or both, as applicable)
☒ Prescription Use (Part 21 CFR 801 Subpart D)  
☐ Over-The-Counter Use (21 CFR 801 Subpart C)
**CONTINUE ON A SEPARATE PAGE IF NEEDED.**
This section applies only to requirements of the Paperwork Reduction Act of 1995.  
***DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.***
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services  
Food and Drug Administration  
Office of Chief Information Officer  
Paperwork Reduction Act (PRA) Staff  
PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
## Page 5
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 1**
# 510 (k) SUMMARY
## 1. Date of Preparation:
September 24, 2025
## 2. Sponsor Identification
**Shanghai United Imaging Healthcare Co.,Ltd.**  
No.2258 Chengbei Rd. Jiading District, 201807, Shanghai, China  
Establishment Registration Number: 3011015597  
Contact Person: Xin GAO  
Position: Regulatory Affairs Specialist  
Tel: +86-021-67076888-5386  
Fax: +86-021-67076889  
Email: xin.gao@united-imaging.com
## 3. Identification of Proposed Device
**Trade Name:** uWS-Angio Pro  
**Common Name:** Angiography X-ray Image Processing Software  
**Model(s):** uWS-Angio Pro
### Regulatory Information
**Classification Name:** Medical image management and processing system  
**Classification:** II  
**Product Code:** LLZ  
**Regulation Number:** 21 CFR 892.2050  
**Review Panel:** Radiology
## 4. Identification of Predicate Device(s)
### Predicate Device
**510(k) Number:** K230955  
**Device Name:** Syngo Application Software
### Reference Device#1
**510(k) Number:** K142273  
**Device Name:** EmboGuide
**K250045**
## Page 6
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 2**
### Reference Device#2
**510(k) Number:** K233209  
**Device Name:** uOmnispace.CT
## 5. Device Description
uWS-Angio Pro is a software intended for viewing, processing, evaluating and analyzing medical images that comply with the DICOM 3.0 protocol. It supports interpretation and evaluation of examinations within healthcare institutions. It can be deployed on independent hardware such as a stand-alone diagnostic review and post-processing workstation. It can also be configured within a network to send and receive DICOM data. Furthermore, it can be deployed on systems of the United Imaging Healthcare Angiography system family.
uWS-Angio Pro contains the following applications:
- uWS-Angio Pro uTarget View
- uWS-Angio Pro uEmbo View
- uWS-Angio Pro uCardiac View
## 6. Indications for use
The uWS-Angio Pro is a post-processing software based on the uWS-Angio Basic for viewing, processing, evaluating and analyzing CT, MR, 3D XA images, and overlaying 2D medical images to support image guidance during interventional procedures. It has the following application:
The uWS-Angio Pro uTarget view application is intended to provide tools for adding the trajectory to the lesion. It also supports overlay of 3D datasets on 2D fluoroscopy images.
The uWS-Angio Pro uEmbo View application is intended to provide users with tools for planning and guiding interventional procedures. It offers a suite of features to mark targets, detect feeder vessels, and overlay the 3D image with the feeders and the corresponding anatomical X-ray image. When the overlay function is activated, it supports automatic 2D-3D image registration specifically for head neuroimaging, while the manual registration function is not restricted to any specific anatomical region.
The uWS-Angio Pro uCardiac View application is intended to provide users tools to plan and guide the interventional procedures. This application can use CT angiography images for vascular access analysis, aortic root analysis and angle management, and overlay registration display with 2D XA images.
## 7. Summary of Technological Characteristics
The technology characteristics of the proposed device reflected in this 510(k)
## Page 7
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 3**
submission are substantially equivalent to those of the predicate device and reference devices.
The following tables present a comparative analysis of the main features, principles of operation, fundamental scientific technology and intended use of the proposed device in relation to both predicate device and reference devices.
## Page 8
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 4**
### Table 1 General information comparison
| Item | Proposed Device uWS-Angio Pro | Predicate Device syngo Application Software (K230955) | Remark |
|------|-------------------------------|---------------------------------------------------|---------|
| General Device Classification Name | Medical Image Management and Processing System | Medical Image Management and Processing System | Same |
| Product Code | LLZ | LLZ | Same |
| Regulation Number | 21 CFR 892.2050 | 21 CFR 892.2050 | Same |
| Device Class | II | II | Same |
| Classification Panel | Radiology | Radiology | Same |
| Advanced Application | Yes | Yes | Same |
The proposed device uWS-Angio Pro and the predicate device syngo Application Software share similar indications for use: providing image viewing and processing to support device guidance during interventional procedures. Both devices are indicated for patients undergoing angiography and fluoroscopy-based procedures and are designed to support healthcare professionals in healthcare institution settings. The intended patient population and applicable clinical scenarios are the same for these two devices. The proposed device includes fewer applications compared to the predicate device. The difference will not impact the safety and effectiveness of the proposed device. Therefore, the proposed device can be considered substantially equivalent to the predicate device in terms of Indications for Use.
### Table 2 Substantial equivalence discussion for uWS-Angio Pro applications
| Application | Function name | Proposed device uWS-Angio Pro | Predicate device syngo Application Software (K230955) | Reference device#1 EmboGuide (K142273) | Reference device#2 uOmnispace.CT (K233209) |
|-------------|---------------|-------------------------------|---------------------------------------------------|----------------------------------------|-------------------------------------------|
## Page 9
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 5**
| uTarget View | Trajectory planning | Yes | Yes | / | / | Note 1 |
|              | Overlay | Yes | Yes | / | / | Same |
|              | Sending position data | Yes | Yes | / | / | Note 2 |
| uEmbo View | Feeder Detection | Yes | / | Yes | / | Same |
|            | Overlay | Yes | / | Yes | / | Same |
| uCardiac View | Vascular Access Analysis | Yes | / | / | Yes | Note 3 |
|               | Aortic Root Analysis | Yes | / | / | Yes | Note 4 |
|               | Overlay | Yes | Yes | / | / | Same |
|               | Sending angle | Yes | Yes | / | / | Note 2 |
**Note 1:** Compared to the predicate device, uTarget view application is intended to provide tools for adding lesion markers (bounding box) and the trajectory to the lesion. The difference doesn't impact the safety and effectiveness of the subject device.
**Note 2:** Compared to the predicate device, position data of the proposed device are compatible to the Angiography Systems of United-Imaging Healthcare. This difference between the proposed device and the reference device doesn't impact the safety and effectiveness of the device.
**Note 3:** Compared to the reference device#2, the name of the function is different. The Vascular Access Analysis is the same as the Vessel analysis function of Cardiovascular Combined Analysis application in the reference device#2. The difference doesn't impact the safety and effectiveness of the subject device.
**Note 4:** Compared to the reference device#2, the Aortic Root Analysis is the same as the combination of TAVI evaluation function and Heart analysis function of Cardiovascular Combined Analysis application in the reference device#2. The difference doesn't impact the safety and effectiveness of the subject device.
## Page 10
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 6**
## 8. Performance Data
The following performance data were provided in support of the substantial equivalence determination.
### Biocompatibility
Not Applicable to the proposed device, because the device is stand-alone software.
### Electrical Safety and Electromagnetic Compatibility (EMC)
Not Applicable to the proposed device, because the device is stand-alone software.
### Software
Software verification and validation testing was provided to demonstrate safety and efficacy of the proposed device. This includes a hazard analysis, and the potential hazards to satisfy the recommended documentation for basic documentation. These documentations include:
- Software Description
- Device Hazard Analysis
- Software Requirements Specification (SRS)
- Software Architecture Design Chart
- Software Development Environment Description
- Software Verification and Validation
- Cybersecurity Documents
### Animal Study
No animal study was required.
### Clinical Studies
No clinical study was required.
### Performance Verification
#### (1) uTarget View
**Workflow Test**
a) **Device Output**
- Trajectory
- entry position data and lateral position data
- overlay planned trajectory with 3D image and 2D XA image
b) **Test Data Description**
- XA CBCT series and CT\MR data of the same patient
c) **Test Method**
- System Test
## Page 11
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 7**
d) **Results**
- The uTarget View generated a trajectory line that is displayed on both the MPR and VR images and added to the trajectory list.
- Sent entry position data and lateral position data to the United Imaging Healthcare Angiography system.
- The uTarget View planned trajectory with 3D image and 2D XA image.
#### (2) uEmbo View
**Path Generation Algorithm**
Based on XA 3D abdominal data or XA 3D head data, the paths to the target points from the catheter port are calculated based on user-marked locations.
e) **Device Output**
- Three-dimensional path to the target points from the catheter port, and it does not involve outputting quantitative parameters.
f) **Test Data Description**
- 40 cases of XA 3D data, including 62 hepatic artery branches from 23 patients and 50 intracranial artery branches from 17 patients.
g) **Test Method**
The path generation result was validated through a subjective evaluation conducted by U.S.-certified physicians.
h) **Results**
To verify the method's effectiveness, we evaluated it on 112 vascular paths from 40 clinical cases. Independent physicians reviewed the results and confirmed that all paths were successfully generated without any critical clinical errors, such as vessel wall penetration or incorrect branching. All paths received final clinical approval.
**Neuro Registration Algorithm**
Based on 2D XA images and 3D XA images, perform 2D-3D registration for data in neural scenes.
a) **Device Output**
The result of 2D-3D registration, and it does not involve outputting quantitative parameters.
b) **Test Data Description**
The test dataset consisted of 37 real clinical cases of head XA data. The dataset was clinically diverse, including patients of varying ages, genders, and disease types (e.g., arterial stenosis, cerebral infarction), and encompassed challenging scenarios such as brain anatomy shift.
c) **Test Method**
## Page 12
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 8**
The accuracy of the registration was evaluated using the mTRE between corresponding points in key anatomical regions, pre- and post-registration.
d) **Results**
All 37 cases across all predefined transformations passed the verification criterion. The overall mean mTRE was 0.24 mm (95% CI: 0.21 to 0.28 mm), significantly below the 1 mm;
The average registration time was 1.75 s (95% CI: 1.69 to 1.82 s).
#### (3) uCardiac View
**Aortic Root Vessel Extraction**
Based on the 3D CTA images, we use deterministic algorithm to segment the aortic root.
a) **Device Output**
Segmentation results
- Aorta
- Left Ventricle
- Left coronary artery
- Right coronary artery
b) **Test Data Description**
- A total of 39 CTA datasets were included, comprising 25 patients from the USA and 14 from China. Among these patients, 25 presented with calcification.
c) **Test Method**
- Evaluation with the ground truth, with evaluation conducted using the DICE coefficient.
d) **Results**
| Volume Targets | Aorta | Left Ventricle | Left Coronary Artery | Right Coronary Artery |
|----------------|-------|----------------|---------------------|----------------------|
| DICE(Algorithm result) | 0.987 (95% CI 0.9862–0.9878) | 0.981 (95% CI 0.9786–0.9834) | 0.911 (95% CI 0.9047–0.9173) | 0.908 (95% CI 0.9002-0.9158) |
**Aortic Vessel Extraction Algorithm**
Based on the 3D CTA images, we use deterministic algorithm to segment the aorta.
a) **Device Output**
Segmentation results
- Aorta
## Page 13
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 9**
b) **Test Data Description**
- A total of 39 CTA datasets were included, comprising 13 patients from the USA and 26 from China. The patient cohort included 10 cases with calcification, 7 with aneurysm, 4 with aortic dissection, and 7 with hematoma.
c) **Test Method**
- Evaluation with the ground truth, with evaluation conducted using the DICE coefficient.
d) **Results**
- The DICE value is 0.968(95% CI 0.9652-0.9708).
**Parameter Calculation**
Based on the 3D CTA images and the preceding image processing, we use simple geometry principle to calculate the parameters, including area, diameter, distance, perimeter and length.
a) **Device Output and Quantitative Parameters**
- Area
- Diameter
- Perimeter
b) **Test Data Description**
- **Aortic Root Parameter Calculation:** A total of 39 CTA datasets were included, comprising 25 patients from the USA and 14 from China. Among these patients, 25 presented with calcification.
- **Aortic Vessel Parameter Calculation:** A total of 39 CTA datasets were included, comprising 13 patients from the USA and 26 from China. The patient cohort included 10 cases with calcification, 7 with aneurysm, 4 with aortic dissection, and 7 with hematoma.
c) **Test Method**
- Evaluation with the ground truth, with evaluation conducted using the intraclass correlation coefficient (ICC) and Bland Altman plots.
d) **Results**
**Aortic Root Parameter Calculation:**
| Parameters | Analysis Results (including ICC and BA-plot) |
|------------|----------------------------------------------|
| Area | ICC: 0.9995 (95% CI: 0.9994 to 0.9995)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -15.5 to +19.0 mm²) |
## Page 14
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 10**
| Maximum diameter | 0.9985 (95% CI: 0.9980 to 0.9989)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -0.64 to +0.63 mm) |
| Minimum diameter | 0.9992 (95% CI: 0.9989 to 0.9994)<br>Bland-Altman analysis: 97.4% of points within limits of agreement (LoA: -0.56 to +0.56 mm) |
| Perimeter | 0.9957 (95% CI: 0.9952 to 0.9960)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -2.2 to +2.6 mm) |
## Page 15
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 11**
**Aortic Vessel Parameter Calculation:**
| Parameter | ICC results & Bland-Altman Analysis |
|-----------|-------------------------------------|
| Area | 0.9991 (95% CI: 0.9988 to 0.9993)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -13.2 to +12.3 mm²) |
| Maximum diameter | 0.9983 (95% CI: 0.9969 to 0.9991)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -0.75 to +0.69 mm) |
## Page 16
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 12**
| Minimum diameter | 0.9979 (95% CI: 0.9960 to 0.9989)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -0.75 to +0.73 mm) |
| Perimeter | 0.9980 (95% CI: 0.9961 to 0.9989)<br>Bland-Altman analysis: 100% of points within limits of agreement (LoA: -2.3 to +2.6 mm) |
**Note: features driven by user-input and the features permitting user editing as follow:**
**Features driven by user input**
| Application | Algorithm | Feature | User input |
|-------------|-----------|---------|------------|
| uTargetView | N.A. | Path Planning | Adding the entry spot and the target spot |
| | N.A. | Bounding Box ROI Placement | Holding down and dragging the mouse on the lesion to draw the long axis. |
| uEmboView | Path Generation | Feeder Detection | The user needs to mark the target points and catheter port |
**Features permitting user editing**
## Page 17
**Shanghai United Imaging Healthcare Co., Ltd.**  
Tel: +86 (21) 67076888 Fax:+86 (21) 67076889  
www.united-imaging.com
**Page 13**
| Application | Algorithm | Editing Content |
|-------------|-----------|-----------------|
| uEmboView | Path Generation | Path Results |
| | Neuro Registration | Registration Results |
| uCardiacView | Aortic Root Vessel Extraction | Segmentation Results |
| | Aortic Root Parameter Calculation | Vascular Contour |
| | Aortic Vessel Extraction | Segmentation Results |
| | Aortic Vessel Parameter Calculation | Vascular Contour |
### Other Standards and Guidance
- NEMA PS 3.1 - 3.20 Digital Imaging and Communications in Medicine (DICOM) Set (2023e).
- ISO 14971 Medical devices - Application of risk management to medical devices (Third Edition 2019-12).
- IEC 62304 Medical device software - Software life cycle processes (Edition 1.1, 2015).
- Cybersecurity in Medical Devices Quality System Considerations and Content of Premarket Submissions.
- Content of Premarket Submissions for Device Software Functions.
### Summary
The features described in this premarket submission are supported with the results of the testing mentioned above; the uWS-Angio Pro is found to have a safety and effectiveness profile that is similar to the predicate device and reference devices.
## 9. Substantially Equivalent (SE) Conclusion
The proposed device is equivalent to the predicate device and reference devices in regard to safety and efficacy. This conclusion is based upon a comparison of intended use, technological characteristics, performance specification, device hazards as well as verification and validation results.
In summary, the proposed device is determined to be Substantially Equivalent (SE) to the predicate device and reference device.