K Number
K130800

Validate with FDA (Live)

Date Cleared
2014-02-18

(333 days)

Product Code
Regulation Number
880.6250
Age Range
0 - 21
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

Powder Free Vinyl Patient Examination Gloved) is a non-sterile disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

Device Description

Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) that meets all of the requirements of ASTM standard D 5250-06(Reaffirmation 2011).

AI/ML Overview

This 510(k) summary describes a medical device, Powder Free Vinyl Patient Examination Gloves, Clear (non-colored), and its substantial equivalence to a predicate device. The document primarily focuses on demonstrating that the new device meets established ASTM standards and FDA requirements for patient examination gloves.

Here's an analysis of your requested information based on the provided text:

Acceptance Criteria and Device Performance

1. Table of Acceptance Criteria and Reported Device Performance

Feature & DescriptionAcceptance Criteria (Predicate/Guidance)Reported Device Performance (Subject Device)
Device Description & SpecsMeets ASTM D5250-06 (Reapproved 2011)Meets ASTM D5250-06 (Reapproved 2011)
Dimensions - LengthASTM D5250, ≥230mm min.230mm min for all sizes
Dimensions - WidthASTM D5250 (Small 80-90 mm, Medium 90-100mm, Large 100-110mm, XLarge 110-120 mm)Small 80-85 mm, Medium 95-97 mm, Large 102-108mm, XLarge 114-118 mm
Dimensions - ThicknessASTM D5250 (Finger 0.05mm min., Palm 0.08mm min.)Finger 0.05mm min., Palm 0.08mm min.
Physical PropertiesASTM D5250 (Before aging/after aging Elongation ≥300%, Tensile Strength ≥14MPa)Before aging/after aging Elongation ≥300%, Tensile Strength > 14MPa
Freedom from Pinholes21 CFR 800.20, ASTM D5250-06 (Reapproved 2011), ASTM D 5151-06 (Reapproved 2011) (AQL 2.5)Meets ASTM D5151-06 (Reapproved 2011) - Holes Inspection Level I, AQL 2.5
Residual PowderASTM D 6124-06 (Reapproved 2011)Meets ASTM D 6124-06 (Reapproved 2011) - Results generated values below 2mg of residual powder
Materials UsedPVC (for vinyl gloves)PVC
Dusting or Donning PowderPU (composition of lubricant and biocompatibility data is typically required for lubricants, but not directly stated as an acceptance criteria for comparing device to predicate)PU and Surface Coating Agent
BiocompatibilitySKIN IRRITATION DERMAL and SENSITIZATION STUDIES, Meets ISO 10993-10:2002/Amd.1:2006SKIN IRRITATION DERMAL and SENSITIZATION STUDIES, Non-irritant or non-sensitizer, Meets ISO 10993-10 Third Edition 2010-08-01

2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

The document does not explicitly state the sample sizes used for testing each characteristic (e.g., number of gloves tested for pinholes, tensile strength). The data provenance is also not specified in terms of country of origin or whether the studies were retrospective or prospective. It only mentions that the subject device "meets" or "generated values" for the standards, implying that internal testing was conducted.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

This information is not applicable to the provided document. The "ground truth" for this device's performance is based on established engineering standards (ASTM, ISO) and FDA regulations, rather than expert clinical judgment or consensus on specific cases. The tests are for objective physical and chemical properties.

4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

This information is not applicable. Adjudication methods are typically associated with subjective assessments or diagnostic interpretations in clinical studies, not the objective measurement of physical properties of a glove.

5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

This is not applicable to the provided document. An MRMC study with AI assistance is relevant for artificial intelligence or imaging devices, not for patient examination gloves.

6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

This is not applicable as the device is a medical glove, not an algorithm or AI-powered system.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

The "ground truth" for this device is based on established objective technical standards and regulatory requirements. Specifically, this includes:

  • ASTM D5250-06 (Reaffirmation 2011) for polyvinyl chloride examination gloves.
  • ASTM D5151-06 (Reaffirmation 2011) for detection of holes in medical gloves.
  • ASTM D6124-06 (Reaffirmation 2011) for residual powder on medical gloves.
  • 21 CFR 800.20 for water leak test on pinhole AQL within FDA regulations.
  • ISO 10993-10 Third Edition 2010-08-01 for biological evaluation of medical devices - irritation and skin sensitization.

The "ground truth" isn't an expert consensus on a subjective interpretation, but rather the defined acceptable parameters and test results dictated by these standards.

8. The sample size for the training set

This is not applicable. The device is a physical medical glove and does not involve any machine learning algorithms or training sets.

9. How the ground truth for the training set was established

This is not applicable for the same reason as above.

{0}------------------------------------------------

Section C

510(k) Summary

"This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92."

"The assigned 510(k) number is: _ K130800 " (applicant leave blank)

Premarket Notification [510(k)] Summary

[(a)(1)]. The summary contains on the first page, preferably on your letterhead paper, the submitter's name, address, phone and fax numbers, name of contact person, and date the summary was prepared :

Submitter's name :Kaixuan Plastic Co., Ltd.
Submitter's address :No.44, Zhonghua St. Shijiazhuang, 050000, China
Phone number :(86) 311-67699828
Fax number :(86) 311-67699906
Name of contact person:Mr. Zhou Rui
Date the summary was prepared:2014-02-07

[(a)(2)]. The name of the device, including the trade or proprietary name if applicable, the common or usual name, and the classification name, if known

Device Name:Powder Free Vinyl Patient Examination Gloves, Clear (non-colored)
Proprietary/Trade name:Powder Free Vinyl Patient Examination Gloves, Clear (non-colored)
Common Name:Patient examination glove
Classification Name:Patient examination glove
Device Classification:I
Regulation Number:21 CFR 880.6250
Panel:General Hospital (80)
Product Code:LYZ

[(a)(3)]. An identification of the legally marketed device to which your firm is claiming substantial equivalence .

Class I* Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) that meets all of the requirements of ASTM standard D 5250-06 (Reaffirmation 2011).

Predicate device : Powder free Vinyl Patient Examination Gloves, Clear(Non-colored), Shijiazhuang Fuguan Plastic Products Co., Ltd. K032908 .

{1}------------------------------------------------

[(a)(4)] A description of the device

Device Description : Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) that meets all of the requirements of ASTM standard D 5250-06(Reaffirmation 2011).

-- How the device functions:

PVC films form a barrier to body fluids and bloodborne Pathogens

-- Scientific concepts that form the basis for the device

The PVC rubber is water tight under normal conditions of use. Its tensile properties cause it to conform to the hand, allowing movements necessary for a medical procedure.

-- Physical and performance characteristics such as design, materials and physical properties: PVC gloves are known to create a barrier to bloodborne pathogens and body fluids. ASTM conforming tensile properties create a glove that is strong and flexible. The glove is manufactured in accordance with the requirements of ASTM D5250 and ASTM D5151 requirements.

[(a)(5)] The summary describes the intended use of the device

Device Intended Use: Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

[(a)(6)] A summary of the technological characteristics of new device compared to the predicate device.

The Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) non sterile are summarized with the following technological characteristics compared to ASTM or equivalent standard.

Features&DescriptionPredicate DeviceMedicalGloveGuidanceManual(1661)Subject DeviceResultofComparison
CompanyShijiazhuang FuguanPlastic Products Co., Ltd.Kaixuan Plastic Co.,Ltd.--
510(K) NumberK032908K130800
Product namePowder Free Vinyl PatientExamination Gloves,Clear(Non-colored)Powder Free VinylPatient ExaminationGloves, Clear(non-colored)Same
Product CodeLYZLYZLYZSame
SizeSmall/ Medium/Large/X largeSmall/ Medium/Large/X largeSubstantiallyequivalent
Intend for usePowder free Vinyl PatientExamination Gloves,Clear(Non-colored)is adisposable deviceintended for medicalpurposes that is worn onthe examiner's hand orfinger to preventcontamination betweenpatient and examiner.Powder FreeExaminationGloves:A powder-freepatient examinationglove is adisposable deviceintended formedical purposesthat is worn on theexaminer's hand orfinger to preventcontaminationbetween patient andexaminer.Powder free VinylPatient ExaminationGloves, Clear(Non-colored) is adisposable deviceintended for medicalpurposes that is worn onthe examiner's hand orfinger to preventcontamination betweenpatient and examiner.Substantiallyequivalent
DeviceDescription andSpecificationsMeets ASTM D5250-06 (Reapproved 2011)If vinyl:Do the vinylexamination glovesmeet all the currentspecifications listedunder ASTMSpecification D5250Meets ASTM D5250-06 (Reapproved 2011)Substantiallyequivalent
or an equivalentconsensus standard?
Dimensions-- LengthMeets ASTM D5250-06 (Reapproved 2011)ASTM D5250230mm min for all sizesSubstantiallyequivalent
≥230mm min.
Dimensions-- WidthMeets ASTM D5250-06 (Reapproved 2011)Substantiallyequivalent
Small 80-90 mmrMedium 90-100mmLarge 100-110mmX large 110-120 mmSmall 80-85 mmMedium 95-97 mmLarge 102-108mmX large 114-118 mm
Dimensions-- ThicknessMeets ASTM D5250-06 (Reapproved 2011)
Finger 0.05mm min.Palm 0.08mm min.Finger 0.05mm min.Palm 0.08mm min.
PhysicalPropertiesMeets ASTM D5250-06 (Reapproved 2011)ASTM D5250Before aging/after agingSubstantiallyequivalent
Before aging/after agingElongation ≥300%Tensile Strength ≥14MPaElongation ≥300%Tensile Strength> 14MPa
FreedomfromPinholesMeets• 21 CFR 800.20• ASTM D5250-06(Reapproved 2011)• ASTM D 5151-06(Reapproved 2011)21 CFR 800.20ASTM D5250ASTM D 5151Meets ASTM D5151-06(Reapproved 2011)HolesInspection Level IAQL2.5Substantiallyequivalent
ResidualPowderMeets ASTM D 6124-06(Reapproved 2011)ASTM D 6124Meets ASTM D 6124-06(Reapproved 2011)Results generatedvalues below 2mg ofresidual powderSubstantiallyequivalent
Compare allmaterials usedto fabricate thedevicesPVCIf the glove is madeof a polymer orother type ofmaterial, identifythe material.PVCSubstantiallyequivalent
Dusting orDonningPowder:PUIf a donninglubricant is used,state thecompositionand includebiocompatibilitydata for thelubricant in anidentifiedattachment; alsostate the name,manufacturer, andaddress belowPUSubstantiallyequivalent
Dusting orDonningPowder: namePULubricantGeneric Name/LubricantBrand NameSurface Coating AgentSubstantiallyequivalent
Compareperformancedata supportingsubstantialequivalenceMeetsASTM D5151-06(Reapproved 2011)ASTM D5250-06(Reapproved 2011)ASTM D6124-06(Reapproved 2011)At this time FDArecognizes thefollowing standards:Patient ExaminationGloves(PVC)ASTMD5151(Detection ofHoles in MedicalGloves)MeetsASTM D5151-06(Reapproved 2011)ASTM D5250-06(Reapproved 2011)ASTM D6124-06(Reapproved 2011)Substantiallyequivalent
SinglePatientUseSingle Patient UseD6124(ResidualPowder on MedicalGloves)ASTMD5250(Poly(vinylchloride) Gloves)Single Patient UseSingle Patient UseSubstantiallyequivalent
BiocompatibilitySKIN IRRITATIONDERMAL andSENSITIZATIONSTUDIES Meets ISO10993-10 :2002/Amd.1:2006SKIN IRRITATIONDERMAL andSENSITIZATIONSTUDIESISO 10993-10The test article was anon-irritant ornon-sensitizerSKIN IRRITATIONDERMAL andSENSITIZATIONSTUDIES Meets ISOISO 10993-10 ThirdEdition 2010-08-01Very similaronly ISO10993-10versionupdatedSubstantiallyequivalent
Labeling for thelegallymarketeddevice to whichsubstantialequivalence isclaimed.-Powder Free-Patient ExaminationGlove-glove color, clear(non-colored)- non sterile-Single Use Only- Manufactured For:- LotChapter 4-Powder Free-Patient ExaminationGlove-glove color, clear(non-colored)- non sterile-Single Use Only- Manufactured For:- LotSubstantiallyequivalent

{2}------------------------------------------------

Section C(rev.03)

{3}------------------------------------------------

[(b)(1)] A brief discussion of the non-clinical submitted, reference, or relied on in the premarket notification submission for a determination of substantial equivalence .

Powder Free Vinyl Patient Examination Gloves, Clear (non-colored)meet requirements per ASTM D5250-06(Reaffirmation 2011), per ASTM D6124-06(Reaffirmation 2011), per 21 CFR 800.20 and ISO 10993-10 Third Edition 2010-08-01.

[(b)(2)] A brief discussion of the clinical submitted, reference, or relied on in the premarket notification submission for a determination of substantial equivalence .

Clinical data is not needed for gloves or for most devices cleared by the 510(k) process.

[(b)(3)] The conclusions drawn from the non-clinical tests that demonstrate that the device is as safe,as effective, and performed as well or better than the legally marketed device identified in (a)(3).

It can be concluded that the Powder Free Vinyl Patient Examination Gloves meet the ASTM standard or equivalent standard and FDA requirements for waterleak test on pinhole AQL., meet labeling claims and the Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) is as safe, as effective, and performs as well as the predicate device, Powder free Vinyl Patient Examination Gloves, Clear(Non-colored), Shijiazhuang Fuguan Plastic Products Co., Ltd. K032908 .

{4}------------------------------------------------

Image /page/4/Picture/0 description: The image shows the logo for the Department of Health & Human Services - USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized emblem featuring a symbol that resembles an abstract eagle or bird-like figure with flowing lines.

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

February 18, 2014

Kaixuan Plastic Company, Limited C/O Mr. Chu Xiaoan Official Correspondent Room 1606 Bldg 1 Jianxiang Yuan #209 Bei Si Huan Zhong Road, Haidian District Beijing 100083 CHINA

Re: K130800

Trade/Device Name: Powder Free Vinyl Patient Examination Gloves, Clear (non-colored) Regulation Number: 21 CFR 880.6250 Regulation Name: Patient Examination Glove Regulatory Class: I Product Code: LYZ Dated: January 2, 2014 Received: January 8, 2014

Dear Mr. Xiaoan:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{5}------------------------------------------------

Page 2 - Mr. Xiaoan

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address >

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Image /page/5/Picture/7 description: The image shows a signature and some text. The text includes "Sincerely yours," followed by a signature. Below the signature, the text reads "Tejashri Purohit-Sheth, M.D., Clinical Deputy Director, DAGRID," and the word "FOR" is at the bottom right.

. Erin I. Keith, M.S. Acting Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration

Indications for Use

Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.

510(k) Number (if known) K 1 30800

Device Name

Powder Free Vinyl Patient Examination Gloves, Clear (Non-colored)

Indications for Use (Describe)

Powder Free Vinyl Patient Examination Gloved) is a non-sterile disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

Type of Use (Select one or both, as applicable) [] Prescription Use (Part 21 CFR 801 Subpart D)

[X] Over-The-Counter Use (21 CFR 801 Subpart C)

PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.

FOR FOR FOR FOA USE ONLY . . 17:1 : 1 :25 Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)

Image /page/6/Picture/12 description: The image shows the name "Elizabeth F. Claverie" in bold font. Below the name, the date and time "2014.02.15 00:27:45 -05'00'" is displayed. The text appears to be extracted from a document or record, possibly indicating a timestamp associated with the individual's name.

{7}------------------------------------------------

This section applies only to requirements of the Paperwork Reduction Act of 1995.

DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

§ 880.6250 Non-powdered patient examination glove.

(a)
Identification. A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.(b)
Classification. Class I (general controls). The device, when it is a finger cot, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.