K Number
K130413
Manufacturer
Date Cleared
2013-03-21

(30 days)

Product Code
Regulation Number
878.4810
Panel
SU
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The PinPointe™ FootLaser™ and the delivery accessories that are used with them are intended for use in surgical procedures involving open, laparoscopic and endoscopic ablation, vaporization, excision, incision, and coagulation of soft tissue in the medical specialties of general and cosmetic dentistry, otolaryngology IENT surgery, and dermatology & plastic surgery including intraoral soft tissue dental surgery, oral maxillo-facial and cosmetic surgery, general surgery, E.N.T. surgery, podiatry, and dermatology and plastic surgery.

Podiatry (ablation, vaporization, incision, excision, and coagulation of soft tissue) including:

  • Matrixectomy
  • Periungual and subungual warts
  • Plantar warts
  • Radical nail excision
  • Neuromas

The PinPointe™ FootLaser™ is indicated for use for the temporary increase of clear nail in patients with onychomycosis (e.g., dermatophytes Trichophyton rubrum and T. mentagrophytes, and/or yeasts Candida albicans, etc.).

Dermatology and Plastic Surgery (ablation, vaporization, excision, and coagulation of soft tissue) including:

  • Lesions of skin and subcutaneous tissue
  • Telangiectasia
  • Port wine lesions
  • Spider veins
  • Hemangiomas
  • Plantar warts
  • Periungual and subungual warts
  • Removal of tattoos
  • Debridement of decubitus ulcer
  • Treatment of keloids

Oropharangeal/ Dental Surgery Indicated for:

  • Abscess incision and drainage
  • Aphthous ulcers treatment
  • Biopsies, excisional and incisional
  • Crown lengthening
  • Exposure of unerupted I partially erupted teeth
  • Fibroma removal
  • Frenectomy
  • Frenotomy
  • Gingival incision and excision
  • Gingivectomy
  • Gingivoplasty
  • Hemostasis
  • Implant removal
  • Lesion (tumor) removal
  • Leukoplakia
  • Operculectomy
  • Oral papillectomy
  • Pulpotomy
  • Pulpotomy as adjunct to root canal therapy
  • Removal of filling material such as gutta percha or resin as adjunct treatment during root canal re-treatment
  • Selective ablation of enamel (first degree) caries removal
  • Sulcular debridement (removal of diseased or inflamed soft tissue in the periodontal pocket) to improve clinical indices including gingival index, gingival bleeding index, probe depth, attachment loss, and tooth mobility
  • Tissue retraction for impressions
  • Vestibuloplasty

General Surgery Indicated for:
Open, laparoscopic, and endoscopic general surgery (ablation, vaporization, incision, and coagulation of soft tissue) including:

  • Cholecystectomy
  • Lymphadenectomy
  • Mastectomy
  • Partial nephrectomy
  • Hepatectomy
  • Pilonidal cystectomy
  • Pancreatectomy
  • Resection of lipoma Splenectomy
  • Pelvic adhesiolysis
  • Hemorrhoidectomy
  • Removal of lesions
  • Thyroidectomy
  • Removal of polyps
  • Parathyroidectomy
  • Removal of tumors
  • Herniorrhaphy
  • Tumor biopsy
  • Tonsillectomy
  • Debridement of decubitus ulcers
  • Appendectomy

Endonasal Surgery
Endonasal surgery (ablation, vaporization, incision, and coagulation of soft tissue) including:

  • Lesions or tumors of the oral, nasal, glossal, pharyngeal & laryngeal tissues
  • Tonsillectomy
  • Adenoidectomy
Device Description

The PinPointe™ FootLaser™ is comprised of the following main components:

  • Main console containing the major electrical components, including:
    • Control/ Display Panel with the:
    • Keyswitch (that controls authorized access to the laser system);
    • emergency Laser Stop button;
    • Displays (laser emission indicator, average power, pulse energy, repetition rate)
    • LCD screen user interface permitting selection of treatment emission when the footswitch is depressed and a fiber optic is properly attached);
  • 1064 nm treatment laser (solid state Nd:Y AG laser rod) with flashlamp and associated light regulation components and electronics;
  • 630 -680 nm (red) aiming beam diode laser;
  • Delivery device fiber-optic connector port;
  • Remote interlock connector (External door interlock connector);
  • Connector ports for the footswitch and power cord;
  • Accessory holder (attached to the rear of the main console);
  • Footswitch;
  • Medical grade power cord;
  • Delivery Devices for Non-Contact and Contact with Intact Skin/Tissue:
    • Guide Tip No Standoff: Reusable, cleanable, tip is provided for noncontactuse to direct and control the placement of the laser beam (free beam) at the treatment location. The Guide tipattaches to the end of the handpiece. The optical fiber is threaded through the handpiece and fits securely into the bore of the Guide tip;
    • Guide Tip - With Standoff: Reusable, cleanable, tip is provided for minimal-contact with intact skin/ tissue to direct and control the placement of the laser beam at the treatment location. The Guide tip attaches to the end of the handpiece. The optical fiber is threaded through the handpiece and fits securely into the bore of the Guide tip;
  • Delivery Devices for Contact with Breached Surfaces:
    • Optical Fibers - Reusable, cleanable, sterilizable optical fibers (range of 200 - 1000 um diameter) provided non-sterile, clean and ready for sterilization (steam autoclave).
    • Handpieces - Reusable, cleanable, sterilizable handpieces (large and small diameter shafts) provided non-sterile, clean and ready for sterilization (steam autoclave). The optical fiber is threaded through the handpiece and secured and held in place with the handpiece locking cap;
    • Handpiece Tips Disposable single-use tips are provided in straight and curved configurations and are used to direct and control the placement of the optical fiber tip at the treatment location. The handpiece tips attach to the end of the handpiece. The optical fiber is threaded through both the handpiece and the handpiece tip;
  • Accessories:
  • Safety Glasses
  • Tools:
    • Optical Fiber Striper;
    • Optical Fiber Cleaver (carbide wedge, ceramic, or equivalent scribe for cleaving the optical fibers).
AI/ML Overview

The provided text is a 510(k) summary for the PinPointe FootLaser, which is a medical device. This document focuses on demonstrating substantial equivalence to a predicate device (K093547).

It explicitly states: "No clinical data was needed for these indications. They are identical to those on K093547." and "The technological characteristics of the PinPointe Footlaser are substantially equivalent to those of the predicate device." and "The PinPointe FootLaser was found to be substantially equivalent to the predicate device."

Therefore, this document does not describe a study that proves the device meets specific acceptance criteria in the way requested by the prompt (e.g., using a test set, ground truth, experts, etc.). Instead, its approval is based on a demonstration of equivalence to a previously approved device.

As such, I cannot provide the requested information regarding acceptance criteria, device performance, sample sizes, experts, adjudication methods, MRMC studies, standalone performance, or details about training sets, because these types of studies were not conducted or reported for this 510(k) submission.

The tables provided in the document compare the characteristics of the "PinPointe FootLaser" (the new device) to the "PinPointe FootLaser" (the predicate device K093547), highlighting their identical specifications and indications for use. This comparison serves as the basis for the declaration of substantial equivalence, not as a report of a new performance study against defined acceptance criteria for the new device itself.

§ 878.4810 Laser surgical instrument for use in general and plastic surgery and in dermatology.

(a)
Identification. (1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
(b)
Classification. (1) Class II.(2) Class I for special laser gas mixtures used as a lasing medium for this class of lasers. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 878.9.