(135 days)
As an artificial root structure for single tooth replacement of mandibular central and lateral incisors and maxillary lateral incisors. The implant may be immediately restored with a temporary prosthesis that is not in functional occlusion.
When splinted together as an artificial root structure for multiple tooth replacement of mandibular incisors. The implants may be restored after a period of time or placed in immediate function.
For denture stabilization using multiple implants in the anterior mandible and maxilla. The implants may be restored after a period of time or placed in immediate function when good primary stability is achieved and with appropriate occlusal loading.
A self-tapping CP Titanium or Titanium Alloy threaded screw, with light grit blasting or roughened surface treatment.
Device Acceptance Criteria and Performance Study Analysis
The provided document describes the 510(k) submission for the I-Mini Dental Implant. However, it does not contain any information about specific acceptance criteria, a study proving the device meets those criteria, or performance data related to such criteria.
The document is a 510(k) summary and FDA clearance letter, which focuses on demonstrating substantial equivalence to legally marketed predicate devices, not on presenting performance data against defined acceptance criteria.
Therefore, I cannot provide the requested information for the following sections as they are not present in the provided text:
- A table of acceptance criteria and the reported device performance
- Sample sizes used for the test set and the data provenance
- Number of experts used to establish the ground truth for the test set and their qualifications
- Adjudication method for the test set
- Multi-Reader Multi-Case (MRMC) comparative effectiveness study, if any, and its effect size
- Standalone (algorithm only) performance study, if any
- Type of ground truth used
- Sample size for the training set
- How the ground truth for the training set was established
Key takeaway from the document:
The I-Mini Dental Implant received 510(k) clearance based on its substantial equivalence to existing predicate devices (IMTEC Sendax MDI and BioHorizons Maestro System 3.0mm) in terms of design, function, labeling, material composition, and intended use, rather than on the basis of new performance data against specific acceptance criteria. This is a common pathway for medical device clearance when a new device is similar enough to previously approved devices.
§ 872.3640 Endosseous dental implant.
(a)
Identification. An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.(b)
Classification. (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
Classification. Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.