K Number
K023080
Device Name
GALIX PACESTAR
Date Cleared
2003-06-11

(267 days)

Product Code
Regulation Number
870.3600
Panel
CV
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The GALIX PaceStar External Paccmaker may be used in any clinical situation in which the use of a temporary pacemaker on a patient provides therapentic or diagnostic value. Specifically, indications for teaporary paccusions include, but are not limited to, the following: - temporary treatment of arrhythmias and heart block . - pro-, intra- and postoperative temporary stimulation of patients undergoing cardiac surgery .

Device Description

Not Found

AI/ML Overview

I am sorry, but the provided text content does not contain the information required to describe the acceptance criteria and the study that proves the device meets those criteria. The document is an FDA 510(k) clearance letter for the GALIX PaceStar External Pacemaker, indicating that the device has been found substantially equivalent to a legally marketed predicate device.

It details the product name, regulation number, regulatory class, and indications for use. However, it does not include any performance data, acceptance criteria, study details (like sample size, data provenance, expert qualifications, adjudication methods, or ground truth establishment), or information about standalone or comparative effectiveness studies.

§ 870.3600 External pacemaker pulse generator.

(a)
Identification. An external pacemaker pulse generator (EPPG) is a prescription device that has a power supply and electronic circuits that produce a periodic electrical pulse to stimulate the heart. This device, which is used outside the body, is used as a temporary substitute for the heart's intrinsic pacing system until a permanent pacemaker can be implanted, or to control irregular heartbeats in patients following cardiac surgery or a myocardial infarction. The device may have adjustments for impulse strength, duration, R-wave sensitivity, and other pacing variables.(b)
Classification. Class II (special controls). The special controls for this device are:(1) Appropriate analysis/testing must validate electromagnetic compatibility (EMC) within a hospital environment.
(2) Electrical bench testing must demonstrate device safety during intended use. This must include testing with the specific power source (
i.e., battery power, AC mains connections, or both).(3) Non-clinical performance testing data must demonstrate the performance characteristics of the device. Testing must include the following:
(i) Testing must demonstrate the accuracy of monitoring functions, alarms, measurement features, therapeutic features, and all adjustable or programmable parameters as identified in labeling;
(ii) Mechanical bench testing of material strength must demonstrate that the device and connection cables will withstand forces or conditions encountered during use;
(iii) Simulated use analysis/testing must demonstrate adequate user interface for adjustable parameters, performance of alarms, display screens, interface with external devices (
e.g. data storage, printing), and indicator(s) functionality under intended use conditions; and(iv) Methods and instructions for cleaning the pulse generator and connection cables must be validated.
(4) Appropriate software verification, validation, and hazard analysis must be performed.
(5) Labeling must include the following:
(i) The labeling must clearly state that these devices are intended for use in a hospital environment and under the supervision of a clinician trained in their use;
(ii) Connector terminals should be clearly, unambiguously marked on the outside of the EPPG device. The markings should identify positive (+) and negative (−) polarities. Dual chamber devices should clearly identify atrial and ventricular terminals;
(iii) The labeling must list all pacing modes available in the device;
(iv) Labeling must include a detailed description of any special capabilities (
e.g., overdrive pacing or automatic mode switching); and(v) Appropriate electromagnetic compatibility information must be included.