K Number
K023005
Date Cleared
2002-10-18

(39 days)

Product Code
Regulation Number
890.3850
Reference & Predicate Devices
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.

Device Description

The Aquilla Modular Wheelchair is manually operated, and can be configured for propulsion by an attendant or an occupant. The range of sizes and build configurations are suitable for male or female sizes from junior to adult. The Aquilla Modular Wheelchair consists of typical components found on most manual wheelchairs. The chairs feature a backrest, folding seat frame, footrest, rear wheels and front castors. Accessories include occupant-positioning belts, and optional features which allow a chair to be changed simply to meet the changing environmental and health requirements of the occupant. Aquilla is suitable for use both indoors and outdoors on surfaces that are intended typically for public access. This type of wheelchair is not suitable for soft and undulating terrain or for climbing obstacles. Aquilla can be easily folded for compact storage, and armrests and footrests can be removed to reduce the weight for lifting. Aquilla is labeled to indicate important aspects of use, including warnings and cautions.

AI/ML Overview

The provided text describes the 510(k) premarket notification for the Aquilla Modular Wheelchair, which is a mechanical wheelchair. The information focuses on its substantial equivalence to a predicate device and its compliance with relevant ISO standards.

Here's an analysis of the requested information based on the provided text:

1. A table of acceptance criteria and the reported device performance

Acceptance Criteria (Set by ISO Standard)Reported Device Performance (Compliance)
ISO 7176-1 (Wheelchairs – Determination of static stability)Met
ISO 7176-3 (Wheelchairs – Determination of effectiveness of brakes)Met
ISO 7176-5 (Wheelchairs – Determination of dimensions, mass and manoeuvring space)Met
ISO 7176-7 (Wheelchairs – Method for measurement of seating and wheel dimensions)Met
ISO 7176-8 (Wheelchairs – Requirements and test methods for static, impact and fatigue strengths)Met
ISO 7176-15 (Wheelchairs – Requirements for information disclosure, documentation and labelling)Met
ISO 7176-16 (Wheelchairs – Resistance to ignition of upholstered parts)Met
ISO 7176-19 (Wheelchairs – Requirements for wheelchairs for use as seats in motor vehicles)Met

2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

The document does not specify the sample size used for the tests. It only states that the "Aquilla wheelchair has been tested to and met the following ISO requirements." The provenance of the data is not explicitly stated beyond the fact that the manufacturer, Remploy Mobility, is located in the United Kingdom. It is implied to be prospective testing carried out for regulatory submission.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

This is not applicable as the device is a mechanical wheelchair and its performance is evaluated against ISO standards through physical testing, not against expert interpretation of medical images or data. No experts for ground truth establishment were mentioned or would be relevant in this context.

4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

This is not applicable. The device undergoes objective physical tests according to ISO standards, which do not involve subjective adjudication methods like those used in clinical or imaging studies.

5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

This is not applicable. The device is a mechanical wheelchair, not an AI-powered diagnostic or assistive technology for human readers. Therefore, an MRMC study is not relevant.

6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

This is not applicable. The device is a mechanical wheelchair, not an algorithm. Performance is assessed through physical tests.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

The "ground truth" in this context is defined by the objective pass/fail criteria established within each of the specified ISO 7176 standards. This involves physical measurements, strength tests, stability tests, and other performance metrics, not expert consensus or medical outcomes.

8. The sample size for the training set

This is not applicable. The Aquilla Modular Wheelchair is a physical device, and its development and testing do not involve a "training set" in the context of machine learning or AI models. Its performance is validated against established engineering and safety standards.

9. How the ground truth for the training set was established

This is not applicable for the reasons stated above.

{0}------------------------------------------------

510(k) SUMMARY 9.

09/04/02

9.1 Submitter's Name and Contact Information

Submitter Company: Bell, Boyd & Lloyd, LLC 70 W. Madison St. Suite 3300 Address: City, State, Zip Chicago, IL 60602

OCT 1 8 2002

Contact Person:Name:Richard O. Wood
Phone/Fax:(312) 807-4364(312) 827-8189 (Fax)
Email:rowood@bellboyd.com
Date Prepared:Date:September 5, 2002

9.2 Name of Device and Name/Address of Applicant

Aquilla Model Wheelchair

Haywood Vocational Opportunities, Inc. 56 Scates St., Waynesville, N.C. 28786,

9.3 Name and Address of Manufacturer

Remploy Mobility Jubilee Industrial Estate, Ashington, Northumberland, United Kingdom NE63 8UE 01670 813718 01670 851990 (Fax)

9.4 Common or Usual Name

Mechanical wheelchair

9.5 Classification Name

Wheelchair, mechanical

{1}------------------------------------------------

09/04/02


KOD 300
2002

9.6 Predicate Device

The Aquilla wheelchair is substantially equivalent to the Breezy® 510 model wheelchairs manufactured by Sunrise Medical (K974820, 1/27/1998).

9.7 Intended Use

The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.

9.8 Technological Characteristics and Substantial Equivalence

9.8.1 Device Description

The Aquilla Modular Wheelchair is manually operated, and can be configured for propulsion by an attendant or an occupant. The range of sizes and build configurations are suitable for male or female sizes from junior to adult.

The Aquilla Modular Wheelchair consists of typical components found on most manual wheelchairs. The chairs feature a backrest, folding seat frame, footrest, rear wheels and front castors. Accessories include occupant-positioning belts, and optional features which allow a chair to be changed simply to meet the changing environmental and health requirements of the occupant.

Aquilla is suitable for use both indoors and outdoors on surfaces that are intended typically for public access. This type of wheelchair is not suitable for soft and undulating terrain or for climbing obstacles. Aquilla can be easily folded for compact storage, and armrests and footrests can be removed to reduce the weight for lifting.

Aquilla is labeled to indicate important aspects of use, including warnings and cautions.

9.8.2 Substantial Equivalence

The Aquilla Modular Wheelchair is substantially equivalent to the Breezy® 510 wheelchair manufactured by Sunrise Medical (K974820, 1/27/98). They are both lightweight wheelchairs with the intended use of providing mobility to occupants unable to walk or have difficulty in walking without assistance.

9.9 Performance Data

The Aquilla wheelchair has been tested to and met the following ISO requirements: ISO 7176-1, -3, -5, -7, -8, -15, -16, -19.

{2}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized graphic of an eagle or bird-like figure, composed of three curved lines that suggest wings and a head.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

OCT 1 8 2002

Haywood Vocational Opportunities Bell, Boyd & Lloyd, LCD c/o Richard O. Wood 70 W. Madison Street, Suite 3300 Chicago, Illinois 60670

Re: K023005

Trade/Device Name: Aquilla Modular Wheelchair Regulation Number: 890.3850 Regulation Name: Wheelchair, mechanical Regulatory Class: Class I Product Code: IOR Dated: September 4, 2002 Received: September 9, 2002

Dear Mr. Wood:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

Page 2 - Mr. Richard O. Wood ·

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely vours.

Sincerely yours,

O Mark N Millenn

Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

510(k) Number (if known):

Device Name: Aquilla Modular Wheelchair

1. INDICATIONS FOR USE:

Aquilla Modular Wheelchair:

The Aquilla Modular Wheelchair is intended to provide mobility for occupants who are unable to walk or have difficulty in walking without assistance.

(PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Mark n Milkerso

(Division Sign-Off) Di ision of General : storative and Neurological Deloces 510(k) Number _

Prescription Use

OR

Over-The-Counter Use X

(Optional Format 1-2-96)

§ 890.3850 Mechanical wheelchair.

(a)
Identification. A mechanical wheelchair is a manually operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.(b)
Classification. Class I (general controls).