K Number
K022659
Device Name
ILLUSION POWDER FREE-PLOYMER COATED COLOR SCENTED NR LATEX EXAMINATION GLOVES (BLUE)
Manufacturer
Date Cleared
2002-09-25

(47 days)

Product Code
Regulation Number
880.6250
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
A patient examination glove is a disposable device intended for medical purposes that is worn upon the examiner's hands or finger to prevent contamination between patient and examiner. Suitable for use in medical examination, diagnostic and therapeutic procedures, as well as in the dentistry field.
Device Description
Illusion Powder Free Polymer Coated Blue Scented (Grape) Latex Examination Glove with Protein Content Labeling Claim (50 Micrograms or Less)
More Information

None

Not Found

No
The device description is for a standard examination glove and there are no mentions of AI, ML, or related concepts in the provided text.

No
The device is a patient examination glove, which is described as preventing contamination between patient and examiner. While it is indicated for use in "therapeutic procedures," its function is not to provide therapy itself, but rather to serve as a barrier during such procedures.

No
Explanation: The device is an examination glove, which is a barrier device used to prevent contamination. While it is used in diagnostic procedures, it does not itself perform any diagnostic function (e.g., measuring, imaging, analyzing data to determine a condition).

No

The device description clearly indicates a physical product (examination glove) and does not mention any software components.

Based on the provided information, this device is not an IVD (In Vitro Diagnostic).

Here's why:

  • Intended Use: The intended use clearly states the device is a "patient examination glove" worn on the hands to prevent contamination between patient and examiner during medical procedures. This is a barrier device for infection control.
  • Device Description: The description details a latex examination glove with specific features (powder-free, polymer coated, scented, protein content). This aligns with a physical barrier device.
  • Lack of IVD Characteristics: There is no mention of the device being used to examine specimens in vitro (outside the body) to provide information for diagnosis, monitoring, or treatment. IVDs typically involve analyzing biological samples like blood, urine, or tissue.

Therefore, this device falls under the category of a medical device used for infection control and examination, not an in vitro diagnostic device.

N/A

Intended Use / Indications for Use

A patient examination glove is a disposable device intended for medical purposes that between patient and examiner. Suitable for use in medical examination, diagnostic and therapeutic procedures, as well as in the dentistry field.

Product codes

LYY

Device Description

Not Found

Mentions image processing

Not Found

Mentions AI, DNN, or ML

Not Found

Input Imaging Modality

Not Found

Anatomical Site

Not Found

Indicated Patient Age Range

Not Found

Intended User / Care Setting

medical examination, diagnostic and therapeutic procedures, as well as in the dentistry field.

Description of the training set, sample size, data source, and annotation protocol

Not Found

Description of the test set, sample size, data source, and annotation protocol

Not Found

Summary of Performance Studies (study type, sample size, AUC, MRMC, standalone performance, key results)

Not Found

Key Metrics (Sensitivity, Specificity, PPV, NPV, etc.)

Not Found

Predicate Device(s)

Not Found

Reference Device(s)

Not Found

Predetermined Change Control Plan (PCCP) - All Relevant Information

Not Found

§ 880.6250 Non-powdered patient examination glove.

(a)
Identification. A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.(b)
Classification. Class I (general controls). The device, when it is a finger cot, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.

0

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/0/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized image of an eagle or bird with three curved lines forming its body and head. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the bird image. The text is in all caps and is evenly spaced around the circle.

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

SFP 2 5 2002

Mr. Liew Yoon Fong Executive Director Purnabina Sdn. Bhd. Plo5, Jalan Mahsuri 1, 7.5KM Jalan Mersing, Kawasan Perindustrian Kluang 86007 Kluang, Johor, MALAYSIA

Re: K022659

Trade/Device Name: Illusion Powder Free Polymer Coated Blue Scented (Grape) Latex Examination Glove with Protein Content Labeling Claim (50 Micrograms or Less) Regulation Number: 880.6250 Regulation Name: Patient Examination Glove Regulatory Class: I Product Code: LYY Dated: August 5, 2002 Received: August 9, 2002

Dear Mr. Fong:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting vour device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

1

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4618. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

Timothy A. Uhlmann

Timothy A. Ulatowski Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

2

  • 3.0 Indications for Use Statement: Include the following or equivalent Indications for Use page. The information, data and labeling claims in the entire the 510(k) submission must support and agree with the Indications for Use statement.

INDICATIONS FOR USE

Applicant:Purnabina Sdn. Bhd.
510(k) Number (if known): *K022659
Device Name:Patient Examination Glove
Indications For Use:

A patient examination glove is a disposable device intended for medical A pactent chamination goothe examiner's hands or finger to prevent purposes that between patient and examiner. Suitable for use in medical examination, diagnostic and therapeutic procedures, as well as in the dentistry field.

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH Office of Device Evaluation (ODE)

Over-The-Counter _____________________________________________________________________________________________________________________________________________________________ Prescription Use OR Per 21 CFR 801.109 (Optional Format 1-2-96)

    • For a new submission, do NOT fill in the 510(k) number blank.
      Olim S. Lion

f Anesthesiology, General Hospital,

510(k) Number. K022659