GUTHRIE PRIME POWDER-FREE
K990228 · Guthrie Medicare Products (Melaka) Sdn Bhd · LYY · Feb 19, 1999 · General Hospital
Device Facts
| Record ID | K990228 |
| Device Name | GUTHRIE PRIME POWDER-FREE |
| Applicant | Guthrie Medicare Products (Melaka) Sdn Bhd |
| Product Code | LYY · General Hospital |
| Decision Date | Feb 19, 1999 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 880.6250 |
| Device Class | Class 1 |
Intended Use
Powder-free Patient Examination glove is a disposable device which is primarily intended for medical purposes to be worn on the examiner's hand or finger to prevent contamination between patient and examiner.
Device Story
Disposable powder-free latex patient examination glove; polymer coated; contains 50 micrograms or less of total water extractable protein per gram. Used in clinical settings by healthcare professionals to provide a protective barrier between the examiner and the patient. Device is non-sterile and intended for single use.
Clinical Evidence
Bench testing only. No clinical data provided.
Technological Characteristics
Material: Latex. Feature: Powder-free, polymer coated. Protein content: ≤50 µg/g total water extractable protein. Form factor: Disposable patient examination glove.
Indications for Use
Indicated for use as a disposable medical glove worn on the examiner's hand or finger to prevent contamination between patient and examiner.
Regulatory Classification
Identification
A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.
Related Devices
- K033532 — ASIA PACIFIC LATEX SDN. BHD. POLYMER COATED POWDER FREE LATEX EXAMINATION GLOVES · Asia Pacific Latex Sdn Bhd · Jan 28, 2004
- K993500 — POWDERFREE LATEX EXAMINATION GLOVES (POLYMER COATED) (PROTEIN LABEL OF 50 MCROGRAM OR LESS) · Besglove Medicare Sdn. Bhd. · Dec 2, 1999
- K031021 — CHLORINATED, POLYMER COATED, POWDER-FREE LATEX EXAMINATION GLOVE · Perusahaan Getah Asas Sdn. Bhd. · Jun 13, 2003
- K990543 — BRIGHTWAY BRAND POLYMER COATED LATEX EXAMINATION GLOVE (POWDER FREE) · Brightway Holdings Sdn. Bhd. · Apr 9, 1999
- K040448 — GENTLE SKIN AND (MULTIPLE LABELS) LATEX EXAMINATION GLOVE, POWDER FREE, POLYMER COATED WITH PROTEIN CLAIM · Rosner-Mautby Meditrade(Thailand) , Ltd. · Mar 23, 2004
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle or bird symbol, with three human profiles incorporated into its design. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular fashion around the bird symbol.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
FEB 1 9 1999
Guthrie Medicare Products (NS) Sdn. Bhd. C/O Ms. Susan D. Goldstein-Falk MDI Consultants, Incorporated 55 Northern Boulevard, Suite 200 Great Neck, New York 11021
Re : K990228 Guthrie Prime Powder-Free Latex Examination Trade Name: Gloves with 50 Micrograms or Less of Total Water Extractable Protein Per Gram Regulatory Class: I Product Code: LYY Dated: January 20, 1999 Received: January 25, 1999
Dear Ms. Goldstein-Falk
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major requlations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) requlation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in Please note: this response to your the Federal Reqister. premarket notification submission does not affect any obligation you might have under sections 531 through 542 of
{1}------------------------------------------------
Paqe 2 - Ms. Goldstein-Falk
the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510 (k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling requlation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4692. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours
Timothy A. Ulatowski
Director Division of Dental, Infection Control, and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
mdi Consultants, Inc.
Attachment #1
ت Page of 1
## K 990228 SIO(K) NUMBER (IF KNOWN) : CATEX Powder-Free (Polymer Coated) Patient Examination Gloves DEVICE NAME: 50 magm OR less of fotal water ary First gloves contain INDICATIONS FOR USE:
Powder-free Patient Examination glove is a disposable device which is primarily Powder-free Patient Examination 'giove is a examiner's hand or finger to prevent Intended for modition between patient and examiner.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801-109) OR
Over-The-Counter-Use (Optional Format 1-2
Qiu S. Lin
(Division Sign-Off) (Division Sign-Ont)
Division of Dental, Infection Control,
Division of Dental, Devices Division of Hospital De 510(k) Number
Page 5
ত্রী c