DSL ESTRONE-SULFATE RIA
Device Facts
| Record ID | K970915 |
|---|---|
| Device Name | DSL ESTRONE-SULFATE RIA |
| Applicant | Diagnostic Systems Laboratories, Inc. |
| Product Code | CGF · Clinical Chemistry |
| Decision Date | May 16, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1280 |
| Device Class | Class 1 |
Indications for Use
The DSL 5400 Estrone-Sulfate RIA assay is intended for the quantitative determination of Estrone-Sulfate in human serum or EDTA plasma. The measurement of Estrone-Sulfate is used for in vitro diagnostic use in the diagnosis and treatment of numerous disorders, including infertility, amenorrhea, differentiation of primary and secondary ovarian malfunction, especially estrogen secreting testicular and ovarian tumors and precocious puberty in females.
Device Story
DSL 5400 Estrone-Sulfate RIA kit; competitive binding protein assay; measures Estrone-Sulfate in human serum/EDTA plasma. Input: patient sample; radio-labeled Estrone-Sulfate competes with sample Estrone-Sulfate for antiserum binding sites. Separation: second antibody (goat anti-rabbit gamma globulin) with polyethylene glycol; centrifugation; decantation. Output: bound counts per minute via gamma counter; concentration inversely proportional to bound counts. Used in clinical laboratory settings by trained personnel. Results assist clinicians in diagnosing/treating infertility, amenorrhea, ovarian/testicular tumors, and precocious puberty.
Clinical Evidence
Bench testing only. Comparative study of 43 patient samples using DSL 5400 and DSL 8700 RIA methods. Linear regression analysis: Y=0.04(X) + 2.89; correlation coefficient r=0.82.
Technological Characteristics
Competitive binding radioimmunoassay (RIA). Reagents: Estrone-Sulfate antiserum, radio-labeled Estrone-Sulfate, second antibody (goat anti-rabbit gamma globulin), polyethylene glycol precipitating aid. Analysis via gamma counter. In vitro diagnostic use.
Indications for Use
Indicated for quantitative measurement of Estrone-Sulfate in human serum or EDTA plasma for diagnosis and treatment of infertility, amenorrhea, ovarian malfunction, estrogen-secreting tumors, and precocious puberty in females.
Regulatory Classification
Identification
An estrone test system is a device intended to measure estrone, an estrogenic steroid, in plasma. Estrone measurements are used in the diagnosis and treatment of numerous disorders, including infertility, amenorrhea, differentiation of primary and secondary ovarian malfunction, estrogen secreting testicular and ovarian tumors, and precocious puberty in females.
Predicate Devices
- DSL 8700 Estrone RIA
Related Devices
- K955356 — ACTIVE ULTRA-SENSITIVE UNCONJUGATED ESTRIOL · Diagnostic Systems Laboratories, Inc. · May 15, 1996
- K041349 — LUMINESCENT IMMUNOASSAY KIT FOR THE DETECTION OF ESTRADIOL IN SALIVA AND SERUM · Ibl GmbH · Sep 24, 2004
- K962895 — DSL DHEA-S-7 · Diagnostic Systems Laboratories, Inc. · Sep 10, 1996
- K971823 — ACTIVE TESTOSTERONE EIA (DSL-10-4000) · Diagnostic Systems Laboratories, Inc. · Jun 16, 1997
- K970126 — ACCESS ESTRADIOL REAGENTS ON THE ACCESS IMMUNOASSAY ANALYZER (33550,33540,33545) · Bio-Rad Laboratories, Inc. · Feb 25, 1997