K Number
K965171

Validate with FDA (Live)

Manufacturer
Date Cleared
1997-01-13

(20 days)

Product Code
Regulation Number
862.1660
Age Range
All
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

Liquichek Urinalysis Control is intended for use as an assayed quality control urine to monitor the precision of laboratory dipstick and microscopic testing procedures for the analytes listed in the package insert.

Device Description

Liquichek Urinalysis Control is prepared from human urine with added human erythrocytes, leukocytes and constituents of non-human origin and pure chemicals. The control is provided in liquid form for convenience.

Level 2 of this product contains 0.1% sodium azide as a preservative.

AI/ML Overview

This document is a 510(k) summary for the Bio-Rad Liquichek Urinalysis Control, a quality control product for laboratory dipstick and microscopic testing. It describes the device, its intended use, and compares its technological characteristics to a substantially equivalent device.

Based on the provided information, the document does not describe acceptance criteria, a study proving the device meets acceptance criteria, or any of the specific details requested in your prompt related to the performance of an AI/ML device.

This a regulatory submission for a laboratory control solution, not an AI or machine learning device. Therefore, the requested information elements (such as sample sizes for test/training sets, expert qualifications, adjudication methods, MRMC studies, standalone performance, etc.) are not applicable to the content of these documents.

If you have a document describing an AI/ML device and its validation studies, I would be happy to analyze it against your criteria.

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logo for Bio-Rad. The logo is in black and white, with the words "BIO-RAD" in bold, sans-serif font. The words are stacked on top of each other and enclosed in a rounded rectangle. The logo is simple and modern, and it is likely used to represent the company's brand.

Bio-Rad
Laboratories

S Division

K965/71

ll

.IAN 13 1997

510(k) Summary

Submitter

Bio-Rad Laboratories, ECS Division 3726 E. Miraloma Avenue Anaheim, CA 92806 (714)630-6400 Fax (714)666-1383

Contact Person Elizabeth Platt

Date of Summary Preparation December 19, 1996

Device (Trade & Common Name) Liquichek Urinalysis Control

Classification Name CFR 862.1660: Urinalysis Controls (Assayed and Unassayed)

Devices to Which Substantial Equivalence is Claimed

Liquid Urine Control Kenlor Industries Westminister, CA K890577

Statement of Intended Use

Liquichek Urinalysis Control is intended for use as an assayed quality control urine to monitor the precision of laboratory dipstick and microscopic testing procedures for the analytes listed in the package insert.

{1}------------------------------------------------

Image /page/1/Picture/0 description: The image shows the logo for BIO-RAD. The logo is in a black rounded rectangle. The text "BIO-RAD" is in white, bold, sans-serif font.

Bio-Rad
Laboratories

ECS Division 3726 E. Miraloma Avenue Anaheim. CA 92806 Telephone (714) 630-6400 Toll Free (800) 854-6737

Description of the Device

Liquichek Urinalysis Control is prepared from human urine with added human erythrocytes, leukocytes and constituents of non-human origin and pure chemicals. The control is provided in liquid form for convenience.

Level 2 of this product contains 0.1% sodium azide as a preservative.

Statement of How Technological Characteristics Compare to Substantial Equivalence Device

A table is provided below comparing the similarities between the Bio-Rad Liquichek Urinalysis Control and the devices to which substantial equivalence is claimed.

Bio-Rad LiquichekUrinalysis ControlLiquid Urine ControlKenlor Industries
IntendedUsean assayed quality controlurine to monitor theprecision of laboratorydipstick and microscopictesting procedures for theanalytes listed in thepackage insertfor monitor the accuracyand precision of dipstick andmicroscopic analysis
FormLiquidLiquid
MatrixHuman UrineHuman Urine
Storage2-8°C2-8°C
Open VialClaim2-8°C for 30 days or 10immersions; 18-25°C for 7days or 10 immersions2-8°C for 2 weeks or 15immersions; roomtemperature for 2 weeks or10 immersions

§ 862.1660 Quality control material (assayed and unassayed).

(a)
Identification. A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.(b)
Classification. Class I (general controls). Except when intended for use in donor screening tests, quality control materials (assayed and unassayed) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.