Intended Use

Coverage HBV is used to inactivate specific bacteria, fungi and viruses on hard inanimate surfaces including reusable non-critical medical devices and environmental surfaces in healthcare facilities.

Device Description

Coverage HBV is a liquid chemical germicide utilizing quatinary ammonium chloride compounds as active ingredients.

AI/ML Overview

The provided text describes a disinfectant product, Coverage HBV, and its effectiveness against various microorganisms. It is not a medical device in the context of AI/ML or image analysis, so the requested information categories regarding acceptance criteria, study methodologies, expert involvement, and ground truth establishment (which are typical for AI/ML-based medical devices) are not applicable.

However, I can extract the information that is present and indicate where the requested categories are not relevant for this type of product.

Description of Coverage HBV and its Effectiveness:

This document is a 510(k) Summary for a General Purpose Disinfectant named Coverage HBV.

1. Table of Acceptance Criteria and Reported Device Performance:

Acceptance Criteria Category (Relevant for AI/ML devices, described for disinfectant effectiveness here)Reported Performance (Disinfectant Effectiveness)
Germicidal EfficacyApproved by EPA as effective against: * S. aureus * S. choleraesuis * Ps. aeruginosa * Other bacteria
Fungicidal EfficacyApproved by EPA as effective against: * T. mentagrophytes * Aspergillus candidus * Aspergillus niger * Candida albicans * Penicillium chermesinum * Penicillin oxalicum * Penicillium spinulosum * Ulocladium sp.
Virucidal EfficacyApproved by EPA as effective against: * Avian Influenza/Turkey/Wisconsin Virus * Cytomegalovirus * Hepatitis B Virus * Herpes Simplex type 2 Virus * Influenza A Virus * Influenza B Virus * Influenza C Virus * Measles Virus * Newcastle Disease Virus * Parainfluenza type 1 Virus * Poliovirus type 1 * Porcine Parovirus * Pseudorabies Virus * T1 bacteriophage * T4 bacteriophage * Vaccinia
Safety DataAcute Oral LD50 (Rats) = 5,000 mg/kg Acute Dermal LD50 (Rabbits) = 2,000 mg/kg Dermal Irritation (Rabbit) neat = Corrosive Eye Irritation (Rabbit) neat = Severe nonreversible irritation Eye Irritation (Rabbit) 1:64 aqueous dilution = No irritation Dermal Sensitization (Guinea Pig) = Negative as sensitizer

Explanation of Non-Applicability for AI/ML-specific questions:

The following requested points are specific to the study and validation of AI/ML-based medical devices, which Coverage HBV (a chemical disinfectant) is not. Therefore, this information is not available or relevant in the provided text.

  1. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective): Not applicable for a chemical disinfectant. The "test set" here refers to the microorganisms and toxicology models used in laboratory effectiveness and safety studies, not a digital dataset.
  2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience): Not applicable. Ground truth for a disinfectant is established through standardized microbiological and toxicological laboratory assays, not expert clinical review.
  3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
  4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is for AI-assisted human reading tasks.
  5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is for AI algorithm performance.
  6. The type of ground truth used (expert consensus, pathology, outcomes data, etc): For a disinfectant, the "ground truth" is determined by the results of standardized laboratory tests demonstrating microbial inactivation and safety, as regulated by bodies like the EPA.
  7. The sample size for the training set: Not applicable. This refers to AI model training data.
  8. How the ground truth for the training set was established: Not applicable.

In summary, the provided document details the effectiveness and safety profiles of a chemical disinfectant according to regulatory approvals (EPA) rather than the performance metrics and study designs typically associated with AI/ML medical devices.

{0}------------------------------------------------

DEC 1 3 1996

510(k) Summary

K964749

Trade Name: Coverage HBV

Common/Usual Name: General Purpose Disinfectant

ConvaTec, Division of E.R. Squibb and Sons, Inc. Submitter/Manufacturer: 5035 Manchester Avenue St. Louis, MO 63110 Establishment Registration Number: 1940768

Contact: Mike Ebers, Manager Regulatory Affairs (314) 535-1390

Description: Coverage HBV is a liquid chemical germicide utilizing quatinary ammonium chloride compounds as active ingredients.

Intended Use: Coverage HBV is used to inactivate specific bacteria, fungi and viruses on hard inanimate surfaces including reusable non-critical medical devices and environmental surfaces in healthcare facilities.

Substantial Equivalence to: (1)Tor Germicidal Cleaner, Huntington Laboratories, (2) Quat-Syl 256, National Laboratories, (3) Futron 25, Hysan Corp.

Comparison to Listed Substantially Equivalent Products: Listed products are also liquid chemical germicides utilizing quatinary ammonium chloride compounds as active ingredients to inactivate specific bacteria, fungi, and viruses on hard inanimate surfaces.

Safety Data: Acute Oral LDso (Rats) = 5,000 mg/kg Acute Dermal LDso (Rabbits) = 2,000 mg/kg Dermal Irritation (Rabbit) neat = Corrosive. Direct contact can cause moderate to severe redness and swelling. Eye Irritation (Rabbit) neat = Severe nonreversible irritation. Eye Irritation (Rabbit) 1:64 aqueous dilution = No irritation Dermal Sensitization (Guinea Pig) = Negative as sensitizer

Effectiveness Data: Germicidal: Approved by EPA as effective against S. aureus, S. choleraesuis and Ps. aeruginosa and other bacteria.

Fungicidal: Approved by EPA as effective against T. mentagrophytes. Also Aspergillus candidus. Aspergillus niger, Candida albicans, Penicillium chermesinum, Penicillin oxalicum, Penicillium spinulosum and Ulocladium sp.

Virucidal: Approved by EPA as effective against Avian Influenza/Turkey/Wisconsin Virus, Cytomegalovirus, Hepatitis B Virus, Herpes Simplex type 2 Virus, Influenza A Virus, Influenza B Virus, Influenza C Virus, Measles Virus, Newcastle Disease Virus, Parainfluenza type 1 Virus, Poliovirus type 1, Porcine Parovirus, Pseudorabies Virus, T1 bacteriophage, T4 bacteriophage and Vaccinia.

§ 880.6890 General purpose disinfectants.

(a)
Identification. A general purpose disinfectant is a germicide intended to process noncritical medical devices and equipment surfaces. A general purpose disinfectant can be used to preclean or decontaminate critical or semicritical medical devices prior to terminal sterilization or high level disinfection. Noncritical medical devices make only topical contact with intact skin.(b)
Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.