RECOVER INFANT HEEL WARMER (5100)

K964523 · Florida Medical Industries, Inc. · MPO · Feb 10, 1997 · Physical Medicine

Device Facts

Record IDK964523
Device NameRECOVER INFANT HEEL WARMER (5100)
ApplicantFlorida Medical Industries, Inc.
Product CodeMPO · Physical Medicine
Decision DateFeb 10, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.5710
Device ClassClass 1
AttributesTherapeutic, Pediatric

Intended Use

The Recover® Infant Heel Warmer is intended to be used for warming the heel site of an infant prior to a heel stick procedure. The warmth enhances vasodilation and increases blood flow in an infant’s heel to ensure adequate blood for sampling.

Device Story

Disposable hot pack; used to warm infant heel prior to blood sampling. Contents: food-grade sodium acetate, water, stainless steel catalytic disc; sealed in nylon/polyethylene laminate bag. Activation via disc manipulation; provides heat to 105°F. Used in clinical settings by healthcare providers to facilitate blood collection; improves sampling success by increasing local blood flow.

Clinical Evidence

Bench testing only; no clinical data provided.

Technological Characteristics

Disposable hot pack; materials: food-grade sodium acetate, water, stainless steel catalytic disc, nylon/polyethylene laminate bag. Thermal energy source: exothermic crystallization triggered by catalytic disc. Form factor: flexible pouch.

Indications for Use

Indicated for infants requiring heel stick blood sampling to enhance vasodilation and blood flow at the heel site.

Regulatory Classification

Identification

A hot or cold disposable pack is a device intended for medical purposes that consists of a sealed plastic bag incorporating chemicals that, upon activation, provides hot or cold therapy for body surfaces.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} K964523 FEB 10 1997 # 510(K) SUMMARY (as required by 807.92(c)) ## Submitter of 510(k): Regulatory & Marketing Services, Inc. (RMS) 40178 U.S. 19 North Tarpon Springs, FL 34689 Phone: 813-942-3908 Fax: 813-942-3828 ## Contact Person: Patrick J. Lamb or Edward H. Ransom ## Date of Summary: October 18, 1996 ## Trade Name: Recover® Infant Heel Warmer ## Classification Name: Pack, Hot, Disposable ## Predicate Device: Florida Medical Industries, Recover® Infant Heel Warmer Pre 1976 Device ## Device Description/ Comparison: Non Toxic, Food Grade Sodium Acetate and water with a stainless steel catalytic disc sealed in a nylon /polyethylene laminate bag. Provides heat to 105°F. | | Proposed Device | Marketed Device | | --- | --- | --- | | | Florida Medical Industries | Florida Medical Industries | | Contents | Food-grade sodium acetate and water. Disc: Stainless Steel Catalytic disc. | Magnesium Sulphate (Kieserite); Colloidal Clay; water. | | Temp. | 105° | 105° | ## Intended Use: The Recover® Infant Heel Warmer is intended to be used for warming the heel site of an infant prior to a heel stick procedure. The warmth enhances vasodilation and increases blood flow in an infant’s heel to ensure adequate blood for sampling.