SPYROFLEX PIGMENTED WOUND DRESSING
Device Facts
| Record ID | K963623 |
|---|---|
| Device Name | SPYROFLEX PIGMENTED WOUND DRESSING |
| Applicant | Polymedica Industries, Inc. |
| Product Code | MGP · SU |
| Decision Date | Oct 25, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Device Class | Class U |
| Attributes | Therapeutic |
Intended Use
SPYROFLEX Pigmented Wound Dressings are intended for use in the management of: Venous stasis ulcers, Partial-thickness wounds, Diabetic ulcers, Superficial burns, Pressure sores, Abrasions and lacerations, Donor sites, Full-thickness wounds, Blisters, Skin tears, Incisions, Dermal lesions, Severe sunburn, Minor chemical burns, Poison Ivy, Thermal burns, Dermabrasions and other dermatologic procedures, Facelifts and other plastic surgery procedures (e.g. laser resurfacing).
Device Story
Sterile, absorptive, adhesive, conformable wound dressing; two-layer construction. Wound contact surface: porous adhesive for application. Second layer: microporous polyurethane membrane; absorbs/stores exudate; moisture vapor permeable; maintains moist environment; impermeable to microorganisms/liquids. Used in clinical/home settings for wound management; applied by clinicians or patients. Provides moist healing environment; protects wound from external contaminants; manages exudate; promotes optimal repair.
Clinical Evidence
Bench testing only; laboratory tests demonstrate device is nontoxic, nonirritating, and nonsensitizing.
Technological Characteristics
Two-layer construction; wound contact surface is porous adhesive; outer layer is microporous polyurethane membrane. Moisture vapor permeable; impermeable to microorganisms and liquids. Sterile.
Indications for Use
Indicated for management of various dermal lesions and injuries including venous stasis ulcers, diabetic ulcers, pressure sores, partial/full-thickness wounds, burns (thermal, chemical, sunburn), abrasions, lacerations, donor sites, blisters, skin tears, incisions, and post-surgical sites (dermatologic, plastic surgery).
Predicate Devices
- SPYROFLEX Wound Dressings
- Wet-Stick
- SPYROFLEX Wound Dressings
- Flexzan Topical Wound Dressings
Related Devices
- K964701 — MITRAFLEX PIGMENTED WOUND DRESSING · Polymedica Industries, Inc. · Feb 7, 1997
- K974520 — SPYROFLEX FOAM ISLAND WOUND DRESSING, SPYROFLEX FOAM ISLAND WOUND DRESSING, TINTED, SPYROFOAM · Innovative Technologies (Us), Inc. · Feb 6, 1998
- K971126 — HYDROCOLLOID WOUND DRESSINGS · Innovative Technologies , Ltd. · Jun 24, 1997
- K982939 — BTF THIN FILM WOUND DRESSING · Bioderm, Inc. · Oct 13, 1998
- K980209 — SIMPLICARE THIN FILM WOUND DRESSINGS · Hollister, Inc. · Feb 20, 1998