DEPUY MOTECH ANTERIOR COMPRESSION PLATE SYSTEM
Device Facts
| Record ID | K962486 |
|---|---|
| Device Name | DEPUY MOTECH ANTERIOR COMPRESSION PLATE SYSTEM |
| Applicant | Depuy, Inc. |
| Product Code | KWQ · Orthopedic |
| Decision Date | Dec 27, 1996 |
| Decision | SN |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3060 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The DePuy Motech PEAK™ Anterior Compression Plate System is intended for use in the treatment of anterior cervical spine instability as a result of fractures, dislocations, subluxations, tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylosis or a previously failed cervical surgery.
Device Story
System consists of Ti-6Al-4V plates and screws for anterior cervical spine stabilization; plates available in 4 design segments and 3 lengths; screws available in 3.5mm cortical and 4.0mm cancellous variants. Used by surgeons in clinical settings to provide fixation for spinal instability; device provides mechanical support to stabilize cervical vertebrae; benefits patient by facilitating fusion and restoring spinal alignment.
Clinical Evidence
Bench testing only; fatigue strength testing performed to compare mechanical performance against predicate devices.
Technological Characteristics
Materials: Ti-6Al-4V alloy. Components: Bone plates and screws. Dimensions: 4 plate segments, 3 lengths; 3.5mm cortical and 4.0mm cancellous screws. Mechanical fixation principle.
Indications for Use
Indicated for patients with anterior cervical spine instability due to fractures, dislocations, subluxations, tumor, degenerative disc disease, spondylosis, or failed prior cervical surgery.
Regulatory Classification
Identification
A spinal intervertebral body fixation orthosis is a device intended to be implanted made of titanium. It consists of various vertebral plates that are punched into each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to a series of vertebrae to correct “sway back,” scoliosis (lateral curvature of the spine), or other conditions.
Predicate Devices
- Acromed AcroPlate Anterior Cervical System
- Codman Anterior Cervical Plate System
- Aesculap Caspar Cervical Plate
Related Devices
- K181562 — Curiteva Anterior Cervical Plate System · Curiteva, LLC · Aug 2, 2018
- K013877 — CODMAN SLIM-LOC SYSTEM · Codman & Shurtleff, Inc. · Dec 19, 2001
- K072703 — PIONEER SLIMFUSE ANTERIOR CERVICAL PLATING SYSTEM · Pioneer Surgical Technology · Jan 10, 2008
- K152455 — Amendia Cervical Plate System · Amendia, Inc. · Oct 15, 2015
- K971730 — DEPUY MOTECH PEAK POLYAXIAL ANTERIOR CERVICAL PLATE SYSTEM · Depuy, Inc. · Nov 3, 1997